Skip to content

All-around best heat pumps by size

The heat pumps of one size and type that score best on heating and cooling together. Each pick shows its heating and cooling halves and the five ratings behind them.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

All-around best, ducted 2 tons

1,110 of 1,182 models in this size class have all five ratings.

  1. 1MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1HMidea (sold as MDV)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    25.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    90.0score / 100Heating 81 · Cooling 99
  2. 2A-ZHP24SA-1with ducted air handler B-ZHP24SA-1Lennox (sold as Comfort Aire)2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    25.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    90.0score / 100Heating 81 · Cooling 99
  3. 3SENE-24EL-OHwith ducted air handler SENE-24EL-IHHSenville2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 80.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Great
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    25.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    90.0score / 100Heating 81 · Cooling 99
  4. 4SL22KLV-024-230A**with ducted air handler CBK48MVT-042-230-Lennox2 tons · 22,600 Btu/h · DuctedCold-climate pick, score 88.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    89.2score / 100Heating 89 · Cooling 90
  5. 5DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikinAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 89.1Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.2 (EER2)
    Great
    88.1score / 100Heating 89 · Cooling 87
  6. 65TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRTraneAlso sold as American Standard 5A5V0X36A12 tons · 26,200 Btu/h · DuctedCold-climate pick, score 90.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    107% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.27 (COP at 5°F)
    Great
    Winter efficiency
    10.3 (HSPF2)
    Top 10%
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    12.3 (EER2)
    Great
    87.2score / 100Heating 90 · Cooling 84
  7. 7AOUH24KWAH3Fujitsu2 tons · 22,000 Btu/h · DuctedCold-climate pick, score 83.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    101% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.08 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.5 (EER2)
    Great
    85.9score / 100Heating 84 · Cooling 88
  8. 8BOVA-36RTB-M20Swith ducted air handler L(E,G)M36FJBosch2 tons · 23,400 Btu/h · DuctedCold-climate pick, score 80.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    93% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.69 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    85.0score / 100Heating 80 · Cooling 90
  9. 9PUZ-AK24NLHZ2***with ducted air handler PVA-AA24NLMitsubishi Electric2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    9.7 (HSPF2)
    Great
    Cooling efficiency
    19.7 (SEER2)
    Great
    Hot-day cooling
    13.6 (EER2)
    Top 10%
    85.0score / 100Heating 79 · Cooling 91
  10. 10NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3BGE Appliances (sold as GE)2 tons · 21,400 Btu/h · DuctedCold-climate pick, score 89.0Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    109% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.73 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.5 (HSPF2)
    Good
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.5 (EER2)
    Great
    84.7score / 100Heating 89 · Cooling 80

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, 2 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    75%+
    Great
    86%+
    Top 10%
    96%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.18+
    Top 10%
    2.43+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    8.9+
    Great
    9.5+
    Top 10%
    10.2+
  • SEER2

    Summer-long cooling efficiency

    Cooling efficiency over a whole summer, measured with a federal test.

    Good
    18.0+
    Great
    19.0+
    Top 10%
    20.0+
  • EER2

    Hot-day cooling efficiency

    Cooling efficiency on a 95°F afternoon.

    Good
    11.7+
    Great
    12.0+
    Top 10%
    13.0+

Next steps

Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter