Skip to content

All-around best heat pumps by size

The heat pumps of one size and type that score best on heating and cooling together. Each pick shows its heating and cooling halves and the five ratings behind them.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

All-around best, ductless 2.5 to 3 tons

1,207 of 1,265 models in this size class have all five ratings.

  1. 1PUZ-AK30NLHZ2***with ductless indoor unit PLA-AE30NLMitsubishi Electric2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 93.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    23.8 (SEER2)
    Great
    Hot-day cooling
    14.0 (EER2)
    Top 10%
    92.8score / 100Heating 94 · Cooling 92
  2. 2RAV-BP301AT2P-ULwith ductless indoor unit RAV-HB301UTP-ULCarrier (sold as Toshiba Carrier)2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 86.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    80% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.8 (HSPF2)
    Top 10%
    Cooling efficiency
    24.5 (SEER2)
    Top 10%
    Hot-day cooling
    14.1 (EER2)
    Top 10%
    91.2score / 100Heating 86 · Cooling 96
  3. 3KUSXA301Awith ductless indoor unit KNSCB301ALG2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 82.6Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.4 (HSPF2)
    Good
    Cooling efficiency
    25.0 (SEER2)
    Top 10%
    Hot-day cooling
    15.2 (EER2)
    Top 10%
    90.4score / 100Heating 83 · Cooling 98
  4. 4AOUH30KUAH1with ductless indoor unit AUUH30KUASFujitsu2.5 tons · 30,000 Btu/h · DuctlessCold-climate pick, score 94.5Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.16 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.0 (HSPF2)
    Top 10%
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    13.7 (EER2)
    Top 10%
    90.2score / 100Heating 95 · Cooling 86
  5. 5M4OD31-27HFN8-M1XDMidea (sold as MDV)2.5 tons · 28,000 Btu/h · DuctlessCold-climate pick, score 83.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    99% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    24.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.5 (EER2)
    Top 10%
    89.4score / 100Heating 84 · Cooling 95
  6. 6MST273G32MHAADaikin (sold as Goodman)2.5 tons · 28,000 Btu/h · DuctlessCold-climate pick, score 83.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    99% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    24.0 (SEER2)
    Top 10%
    Hot-day cooling
    14.5 (EER2)
    Top 10%
    89.4score / 100Heating 84 · Cooling 95
  7. 7MCY-MUB0368HS2P-ULCarrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 78.6Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.42 (COP at 5°F)
    Top 10%
    Winter efficiency
    12.1 (HSPF2)
    Top 10%
    Cooling efficiency
    29.1 (SEER2)
    Top 10%
    Hot-day cooling
    17.2 (EER2)
    Top 10%
    89.3score / 100Heating 79 · Cooling 100
  8. 8ZRUM036GSS0LG3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 90.1Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Top 10%
    Winter efficiency
    10.6 (HSPF2)
    Great
    Cooling efficiency
    23.0 (SEER2)
    Great
    Hot-day cooling
    15.5 (EER2)
    Top 10%
    89.1score / 100Heating 90 · Cooling 88
  9. 9RAV-BP361AT2P-ULwith ductless indoor unit RAV-HB361UTP-ULCarrier (sold as Toshiba Carrier)3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 85.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    79% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.20 (COP at 5°F)
    Top 10%
    Winter efficiency
    11.3 (HSPF2)
    Top 10%
    Cooling efficiency
    24.8 (SEER2)
    Top 10%
    Hot-day cooling
    13.4 (EER2)
    Top 10%
    88.4score / 100Heating 84 · Cooling 93
  10. 10PUZ-AK36NLHZ2***with ductless indoor unit PLA-AE36NLMitsubishi Electric3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 84.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Great
    Winter efficiency
    10.5 (HSPF2)
    Great
    Cooling efficiency
    23.3 (SEER2)
    Great
    Hot-day cooling
    13.7 (EER2)
    Top 10%
    87.8score / 100Heating 85 · Cooling 91

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ductless, 2.5 to 3 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    72%+
    Great
    97%+
    Top 10%
    100%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.02+
    Top 10%
    2.12+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    10.0+
    Great
    10.5+
    Top 10%
    10.7+
  • SEER2

    Summer-long cooling efficiency

    Cooling efficiency over a whole summer, measured with a federal test.

    Good
    21.0+
    Great
    23.0+
    Top 10%
    24.0+
  • EER2

    Hot-day cooling efficiency

    Cooling efficiency on a 95°F afternoon.

    Good
    12.0+
    Great
    12.5+
    Top 10%
    13.1+

Next steps

Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter