Skip to content

All-around best heat pumps by size

The heat pumps of one size and type that score best on heating and cooling together. Each pick shows its heating and cooling halves and the five ratings behind them.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

All-around best, ducted 3.5 to 4.5 tons

2,262 of 2,660 models in this size class have all five ratings.

  1. 1KUMXA421ALG3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 89.3Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.27 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    13.1 (EER2)
    Top 10%
    91.2score / 100Heating 89 · Cooling 93
  2. 227VNA154A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA4.5 tons · 51,500 Btu/h · DuctedCold-climate pick, score 81.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    102% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    10.5 (HSPF2)
    Top 10%
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    90.4score / 100Heating 82 · Cooling 99
  3. 3KUMXA481ALG4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 90.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.33 (COP at 5°F)
    Great
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    12.6 (EER2)
    Top 10%
    90.2score / 100Heating 90 · Cooling 90
  4. 45TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRPTrane3.5 tons · 42,500 Btu/h · DuctedCold-climate pick, score 92.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    107% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.74 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Great
    89.2score / 100Heating 92 · Cooling 86
  5. 5ASUM42HPMULOAUX3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 77.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    83% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    22.0 (SEER2)
    Top 10%
    Hot-day cooling
    12.3 (EER2)
    Top 10%
    87.2score / 100Heating 77 · Cooling 97
  6. 6BOVA-60MTB-M19Ewith ducted air handler (V,R)60H210P19*+TXV+AEFE5Bosch4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 90.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    103% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.5score / 100Heating 85 · Cooling 88
  7. 7SL22KLV-048-230A**with indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH080NV60CLennox4 tons · 46,000 Btu/h · DuctedCold-climate pick, score 84.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Good
    Winter efficiency
    9.4 (HSPF2)
    Great
    Cooling efficiency
    20.5 (SEER2)
    Top 10%
    Hot-day cooling
    12.4 (EER2)
    Top 10%
    86.5score / 100Heating 76 · Cooling 97
  8. 8RD18AY48AJVCwith ducted air handler L(E,G)M60IJRheem3.5 tons · 39,000 Btu/h · DuctedCold-climate pick, score 95.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    104% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.80 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.0 (HSPF2)
    Good
    Cooling efficiency
    18.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.4score / 100Heating 90 · Cooling 83
  9. 95A6V0X48A1with indoor coil DH60T4J and furnace S8V2D120M5PCBTrane (sold as American Standard)3.5 tons · 44,500 Btu/h · DuctedCold-climate pick, score 79.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.10 (COP at 5°F)
    Good
    Winter efficiency
    10.0 (HSPF2)
    Great
    Cooling efficiency
    20.4 (SEER2)
    Top 10%
    Hot-day cooling
    12.0 (EER2)
    Great
    86.1score / 100Heating 80 · Cooling 93
  10. 10HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDRYork (sold as Coleman)3.5 tons · 43,000 Btu/h · DuctedCold-climate pick, score 90.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    81% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.80 (COP at 5°F)
    Top 10%
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    86.0score / 100Heating 84 · Cooling 88

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, 3.5 to 4.5 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    71%+
    Great
    83%+
    Top 10%
    98%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.10+
    Top 10%
    2.35+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    8.1+
    Great
    9.0+
    Top 10%
    10.4+
  • SEER2

    Summer-long cooling efficiency

    Cooling efficiency over a whole summer, measured with a federal test.

    Good
    15.8+
    Great
    18.0+
    Top 10%
    19.5+
  • EER2

    Hot-day cooling efficiency

    Cooling efficiency on a 95°F afternoon.

    Good
    11.1+
    Great
    11.7+
    Top 10%
    12.0+

Next steps

Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter