- Insights
- Cold-climate picks
Both views use the same certified data. This device remembers your choice.
All-around best heat pumps by size
The heat pumps of one size and type that score best on heating and cooling together. Each pick shows its heating and cooling halves and the five ratings behind them.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 3.5 to 4.5 tons (39,000 to 56,999 Btu/h cooling). What size is my system?
All-around best, ducted 3.5 to 4.5 tons
2,262 of 2,660 models in this size class have all five ratings.
- 1KUMXA421ALG3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 89.3Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.27 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 13.1 (EER2)
- Top 10%
- 227VNA154A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 291VAN054**AA4.5 tons · 51,500 Btu/h · DuctedCold-climate pick, score 81.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 102% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.5 (HSPF2)
- Top 10%
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 3KUMXA481ALG4 tons · 48,000 Btu/h · DuctedCold-climate pick, score 90.4Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.33 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 18.5 (SEER2)
- Great
- Hot-day cooling
- 12.6 (EER2)
- Top 10%
- 45TWV0X48A1with indoor coil D(A,C,E)60B4J+TDR and furnace L8V1C100U5VSB+LRPTrane3.5 tons · 42,500 Btu/h · DuctedCold-climate pick, score 92.8Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 107% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.74 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 11.7 (EER2)
- Great
- 5ASUM42HPMULOAUX3.5 tons · 42,000 Btu/h · DuctedCold-climate pick, score 77.1Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 22.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.3 (EER2)
- Top 10%
- 6BOVA-60MTB-M19Ewith ducted air handler (V,R)60H210P19*+TXV+AEFE5Bosch4 tons · 48,500 Btu/h · DuctedCold-climate pick, score 90.7Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 103% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 7SL22KLV-048-230A**with indoor coil CK40[C,U]T-60C-**+TDR and furnace SL280UH080NV60CLennox4 tons · 46,000 Btu/h · DuctedCold-climate pick, score 84.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Winter efficiency
- 9.4 (HSPF2)
- Great
- Cooling efficiency
- 20.5 (SEER2)
- Top 10%
- Hot-day cooling
- 12.4 (EER2)
- Top 10%
- 8RD18AY48AJVCwith ducted air handler L(E,G)M60IJRheem3.5 tons · 39,000 Btu/h · DuctedCold-climate pick, score 95.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 104% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.80 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.0 (HSPF2)
- Good
- Cooling efficiency
- 18.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
- 95A6V0X48A1with indoor coil DH60T4J and furnace S8V2D120M5PCBTrane (sold as American Standard)3.5 tons · 44,500 Btu/h · DuctedCold-climate pick, score 79.8Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 90% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 20.4 (SEER2)
- Top 10%
- Hot-day cooling
- 12.0 (EER2)
- Great
- 10HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDRYork (sold as Coleman)3.5 tons · 43,000 Btu/h · DuctedCold-climate pick, score 90.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 81% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.80 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.5 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 3.5 to 4.5 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 71%+
- Great
- 83%+
- Top 10%
- 98%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.35+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 8.1+
- Great
- 9.0+
- Top 10%
- 10.4+
SEER2
Summer-long cooling efficiency
Cooling efficiency over a whole summer, measured with a federal test.
- Good
- 15.8+
- Great
- 18.0+
- Top 10%
- 19.5+
EER2
Hot-day cooling efficiency
Cooling efficiency on a 95°F afternoon.
- Good
- 11.1+
- Great
- 11.7+
- Top 10%
- 12.0+
Next steps
Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.
Open the advanced view