Skip to content

Ranked by efficiency on a 5°f day only

How much heat the unit makes from each unit of electricity when it is 5°F outside. An electric baseboard heater has a COP of 1, so a COP of 2 means twice the heat from the same electricity in the 5°F test. This list ranks by that one rating only; the cold-climate picks combine three ratings.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Top 10 by efficiency on a 5°f day only: ducted, up to 1.5 tons

Every model here is the same size and type, so the numbers compare directly. Higher is better. One certified pairing per model.
  1. 137MUHAQ18AA3with indoor coil D(A,C,E)31A3J+TDR and furnace 58SU*B080M21**20Carrier1.5 tons · 17,200 Btu/h · DuctedTop 10%3.30
  2. 2HH824E2S11with indoor coil D(A,C,E)37E2J+TDR and furnace Y82E080B12LMPS1York1.5 tons · 20,600 Btu/h · DuctedTop 10%3.20
  3. 337MUHAQ18AA3+TIC2025-0016with ducted air handler L(E,G)M36DJCarrier1.5 tons · 18,000 Btu/h · DuctedTop 10%3.18
  4. 4KUSXB181Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 16,800 Btu/h · DuctedTop 10%3.17
  5. 5RP15AY24AJ2Nwith ducted air handler AEN+CM24C2J+TDRRheem (sold as RUUD)1.5 tons · 20,600 Btu/h · DuctedTop 10%3.05
  6. 6KUSXA181Awith ducted air handler D(A,C,E)25C3D+TDRLG1.5 tons · 16,900 Btu/h · DuctedTop 10%3.01
  7. 75TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons · 19,800 Btu/h · DuctedTop 10%2.99
  8. 8KUSXB241Awith ducted air handler D(A,C,E)30C3D+TDRLG1.5 tons · 20,400 Btu/h · DuctedTop 10%2.95
  9. 95A6V0X24A1with indoor coil D(A,C,E)24B4J+TDR and furnace L8V1A060U3VSB+LRPTrane (sold as American Standard)1.5 tons · 19,500 Btu/h · DuctedTop 10%2.93
  10. 10SUZ-AA18NL***with ducted air handler SEZ-AD18NLMitsubishi Electric1.5 tons · 18,000 Btu/h · DuctedTop 10%2.93

Every ducted, up to 1.5 tons model, highest first

Top cold-climate picks, ducted up to 1.5 tons

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, up to 1.5 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    74%+
    Great
    90%+
    Top 10%
    100%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    1.90+
    Great
    2.10+
    Top 10%
    2.32+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    9.2+
    Great
    10.0+
    Top 10%
    10.6+