- Insights
- Cold-climate picks
Both views use the same certified data. This device remembers your choice.
Ranked by hot-day cooling efficiency only
Cooling efficiency on a 95°F afternoon. A single hot-weather test point, when air conditioners work hardest. Higher is more efficient. This list ranks by that one rating only; the cold-climate picks combine three ratings.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
Top 10 by hot-day cooling efficiency only: ducted, 5 tons and up
- 127TPA860A**30*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 248TAN060**AA, Bryant Heating and Cooling Systems PH8TAN560**AA, HEIL N5H8T60*K*AAA, Grandaire W5H8T60*K*AAA and 1 more; also listed as GH8TAN560**AA5 tons · 57,500 Btu/h · DuctedGood13.0
- 2H5H8T60*K*AAA*with ducted air handler FTMA5B60L0DCarrier (sold as HEIL)Also sold as Comfortmaker C5H8T60*K*AAA, Kenmore (C,H,T)5H8T60*K*AAA, Tempstar T5H8T60*K*AAA5 tons · 57,500 Btu/h · DuctedGreat13.0
- 3WHK060A3**0***0TraneAlso sold as American Standard WHK060AW**0***0, American Standard WHK060AW**(B,E,G,K)***0, American Standard WHK060AW**0***2, American Standard WHK060AW**(B,E,G,K)***2 and 2 more; also listed as WHK060A4**0***0, WHK060A3**0***2, WHK060A4**0***2, WHK060A3**0***4 and 16 more5 tons · 60,000 Btu/h · DuctedTop 10%12.8
- 427SCA560A**30*with ducted air handler FT5ANBD60LCarrierAlso sold as Bryant Heating and Cooling Systems 235SAN060**AA, Bryant Heating and Cooling Systems 246SAN060**AA, Bryant Heating and Cooling Systems PH5SAN560**AA, HEIL N5H5S60*K*AAA and 3 more; also listed as 27SPA660A**30, GH5SAN560**AA5 tons · 57,000 Btu/h · DuctedGreat12.5
- 5H5H6S60*K*AAA*with ducted air handler FTMA5B60L0DCarrier (sold as HEIL)Also sold as Comfortmaker C5H6S60*K*AAA, Kenmore (C,H,T)5H6S60*K*AAA, Tempstar T5H6S60*K*AAA; also listed as B5H6S60*K*AAA5 tons · 57,000 Btu/h · DuctedTop 10%12.5
- 627VNA360A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedTop 10%12.5
- 7H5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCONCarrier (sold as HEIL)Also sold as Comfortmaker C5H3V60*K*AAA, Kenmore (C,H,T)5H3V60*K*AAA, Tempstar T5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedBelow the middle12.5
- 8EL16KP1-060-230A**with indoor coil LD42/61Z*+TXV and furnace EL280UH110E60CLennoxAlso sold as Ducane 7HP14F60P-**A, Armstrong Air A7HP14F60P-**A; also listed as ML14KP1-060-230A5 tons · 57,500 Btu/h · DuctedGreat12.5
- 9BH714S60P-**Awith indoor coil PL60H210P50*+TXV and furnace B80UR1102E5CGree (sold as Ac Pro)5 tons · 57,500 Btu/h · DuctedGood12.5
- 10HSA1460S1-**Awith indoor coil 7ED60DX-**+TDR and furnace GDD80C110C5MPLennox (sold as Comfort-Aire)5 tons · 57,000 Btu/h · DuctedGreat12.4
Every ducted, 5 tons and up model, highest first
Top cold-climate picks, ducted 5 tons and up
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 5 tons and up
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.20+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 7.2+
- Great
- 9.0+
- Top 10%
- 9.5+
SEER2
Summer-long cooling efficiency
Cooling efficiency over a whole summer, measured with a federal test.
- Good
- 15.4+
- Great
- 17.0+
- Top 10%
- 18.0+
Next steps
Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.
Open the advanced view