Skip to content

Ranked by summer-long cooling efficiency only

Cooling efficiency over a whole summer, measured with a federal test. Like miles per gallon for cooling: higher means more cooling per unit of electricity over the test season. The federal minimum for a new split heat pump is 14.3. This list ranks by that one rating only; the cold-climate picks combine three ratings.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Top 10 by summer-long cooling efficiency only: ducted, 2.5 to 3 tons

Every model here is the same size and type, so the numbers compare directly. Higher is better. One certified pairing per model.
  1. 127VNA336A*030*with indoor coil CVAMA6124XMA*+UI and furnace 58TN*B090C21**20CarrierAlso sold as Bryant Heating and Cooling Systems 293VAN036**AA, HEIL H5H3V36*K*AAA, Comfortmaker C5H3V36*K*AAA, Kenmore (C,H,T)5H3V36*K*AAA and 2 more3 tons · 36,000 Btu/h · DuctedTop 10%22.5
  2. 2048-TPH-MODU-1D4Della2.5 tons · 27,000 Btu/h · DuctedTop 10%22.0
  3. 3ASPR27HPMULOAUX2.5 tons · 27,000 Btu/h · DuctedTop 10%22.0
  4. 4PUZ-AK30NLHZ***with ducted air handler PEAD-AA30NLMitsubishi Electric2.5 tons · 30,000 Btu/h · DuctedTop 10%21.7
  5. 5PUZ-AK36NLHZ***with ducted air handler PEAD-AA36NLMitsubishi Electric3 tons · 36,000 Btu/h · DuctedTop 10%21.7
  6. 6PUZ-AK30NLHZ2***with ducted air handler PEAD-AA30NLMitsubishi Electric2.5 tons · 30,000 Btu/h · DuctedTop 10%21.7
  7. 7PUZ-AK36NLHZ2***with ducted air handler PEAD-AA36NLMitsubishi Electric3 tons · 36,000 Btu/h · DuctedTop 10%21.7
  8. 85TWV0X36A1with ducted air handler 5TEMCD06AV41+TDRTraneAlso sold as American Standard 5A6V0X36A13 tons · 36,200 Btu/h · DuctedTop 10%21.6
  9. 9ASUM36HPMULOAUX3 tons · 36,000 Btu/h · DuctedTop 10%21.5
  10. 10D5CMRAH30EAKMideaAlso sold as MDV M5OD30-30HFN10-M1D, Bryant 37MGRAQ30EA3, Arcoaire D5CMRAH30EAK; also listed as 37MGRAQ30EA32.5 tons · 30,000 Btu/h · DuctedTop 10%21.0

Every ducted, 2.5 to 3 tons model, highest first

Top cold-climate picks, ducted 2.5 to 3 tons

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, 2.5 to 3 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.10+
    Top 10%
    2.33+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    8.3+
    Great
    9.2+
    Top 10%
    10.2+
  • SEER2

    Summer-long cooling efficiency

    Cooling efficiency over a whole summer, measured with a federal test.

    Good
    16.5+
    Great
    18.5+
    Top 10%
    19.4+

Next steps

Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy