Skip to content

Top cold-climate picks by size

The heat pumps of one size and type that hold up best when it is 5°F outside. Each pick shows its score and the three ratings behind it.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Top cold-climate picks, ducted 2 tons

791 of 1,221 models in this size class qualify. 358 keep less than 70% of their heat at 5°F and 66 have no 5°F heat output rating, so they cannot qualify.

  1. 1HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDRYork (sold as Coleman)2 tons · 21,000 Btu/h · DuctedKeeps 111% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    111% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    3.03 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    9.5 (HSPF2)
    Good
    90.1score / 100
  2. 25TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRTraneAlso sold as American Standard 5A5V0X36A12 tons · 26,200 Btu/h · DuctedKeeps 107% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    107% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.27 (COP at 5°F)
    Great
    Seasonal efficiency
    10.3 (HSPF2)
    Top 10%
    89.9score / 100
  3. 3NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3BGE Appliances (sold as GE)2 tons · 21,400 Btu/h · DuctedKeeps 109% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    109% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.73 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    9.5 (HSPF2)
    Good
    89.1score / 100
  4. 4DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikinAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA2 tons · 24,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    100% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    2.40 (COP at 5°F)
    Great
    Seasonal efficiency
    10.0 (HSPF2)
    Great
    89.1score / 100
  5. 5SL22KLV-024-230A**with ducted air handler CBK48MVT-042-230-Lennox2 tons · 22,600 Btu/h · DuctedKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    96% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.30 (COP at 5°F)
    Great
    Seasonal efficiency
    10.5 (HSPF2)
    Top 10%
    88.5score / 100
  6. 6O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-OMRCOOL2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.18 (COP at 5°F)
    Good
    Seasonal efficiency
    11.7 (HSPF2)
    Top 10%
    86.5score / 100
  7. 7NS18H24HA5***with indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances2 tons · 23,200 Btu/h · DuctedKeeps 94% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
    Heat kept at 5°F
    94% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.87 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    9.5 (HSPF2)
    Good
    86.4score / 100
  8. 8BMS500-AAS024-1CSXHDwith ducted air handler BMS500-AAU024-1AHDXDBosch2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.18 (COP at 5°F)
    Good
    Seasonal efficiency
    11.7 (HSPF2)
    Top 10%
    85.8score / 100
  9. 937MAHAQ24AA3with ducted air handler 45MBDAQ24XH3CarrierAlso sold as Midea 37MAHAQ24AA3, Midea D5CSHAH24AAK, MDV MOD30-24HFN10-M1X, Arcoaire D5CSHAH24AAK2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.18 (COP at 5°F)
    Good
    Seasonal efficiency
    11.7 (HSPF2)
    Top 10%
    85.8score / 100
  10. 10DRA1H24S2Awith ducted air handler DRADH24F2ADurastar2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    92% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.18 (COP at 5°F)
    Good
    Seasonal efficiency
    11.7 (HSPF2)
    Top 10%
    85.8score / 100

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, 2 tons

Good is better than half of this size class, great is the top quarter, top is the top 10%, all from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    75%+
    Great
    86%+
    Top 10%
    96%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    2.00+
    Great
    2.18+
    Top 10%
    2.43+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    8.9+
    Great
    9.5+
    Top 10%
    10.2+

Next steps

Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter