- Insights
- Cold-climate picks
Both views use the same certified data. This device remembers your choice.
Top cold-climate picks by size
The heat pumps of one size and type that hold up best when it is 5°F outside. Each pick shows its score and the three ratings behind it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 2 tons (21,000 to 26,999 Btu/h cooling). What size is my system?
Top cold-climate picks, ducted 2 tons
791 of 1,221 models in this size class qualify. 358 keep less than 70% of their heat at 5°F and 66 have no 5°F heat output rating, so they cannot qualify.
- 1HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDRYork (sold as Coleman)2 tons · 21,000 Btu/h · DuctedKeeps 111% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 111% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 3.03 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 25TCV0X36A1with ducted air handler 5TEMCD04AV31+TDRTraneAlso sold as American Standard 5A5V0X36A12 tons · 26,200 Btu/h · DuctedKeeps 107% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 107% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.27 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.3 (HSPF2)
- Top 10%
- 3NS21H24MA5-**Awith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3BGE Appliances (sold as GE)2 tons · 21,400 Btu/h · DuctedKeeps 109% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 109% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.73 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 4DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikinAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA2 tons · 24,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 5SL22KLV-024-230A**with ducted air handler CBK48MVT-042-230-Lennox2 tons · 22,600 Btu/h · DuctedKeeps 96% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 96% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 6O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-OMRCOOL2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 7NS18H24HA5***with indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances2 tons · 23,200 Btu/h · DuctedKeeps 94% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 94% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.87 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 8BMS500-AAS024-1CSXHDwith ducted air handler BMS500-AAU024-1AHDXDBosch2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 937MAHAQ24AA3with ducted air handler 45MBDAQ24XH3CarrierAlso sold as Midea 37MAHAQ24AA3, Midea D5CSHAH24AAK, MDV MOD30-24HFN10-M1X, Arcoaire D5CSHAH24AAK2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
- 10DRA1H24S2Awith ducted air handler DRADH24F2ADurastar2 tons · 24,000 Btu/h · DuctedKeeps 92% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 92% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Good
- Seasonal efficiency
- 11.7 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 2 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 75%+
- Great
- 86%+
- Top 10%
- 96%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.18+
- Top 10%
- 2.43+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 8.9+
- Great
- 9.5+
- Top 10%
- 10.2+
Next steps
Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.
Open the advanced view