- Insights
- Cold-climate picks
Both views use the same certified data. This device remembers your choice.
Top cold-climate picks by size
The heat pumps of one size and type that hold up best when it is 5°F outside. Each pick shows its score and the three ratings behind it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, 5 tons and up (57,000 Btu/h and up cooling). What size is my system?
Top cold-climate picks, ducted 5 tons and up
81 of 495 models in this size class qualify. 281 keep less than 70% of their heat at 5°F and 133 have no 5°F heat output rating, so they cannot qualify.
- 1MCY-MUB0608HS2P-ULCarrier (sold as Toshiba Carrier)5 tons · 60,000 Btu/h · DuctedKeeps 73% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 73% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.22 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.1 (HSPF2)
- Top 10%
- 2KUMXB601ALG5 tons · 60,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.33 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.5 (HSPF2)
- Great
- 3AVW-60F3DAH2Hisense5 tons · 60,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.1 (HSPF2)
- Top 10%
- 4CHV6-RS60URBMHHCooper&Hunter (sold as Cooper & Hunter)5 tons · 60,000 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.1 (HSPF2)
- Top 10%
- 5AUWR-60U3TH5with ducted air handler AUH-60UX3TEH3Hisense5 tons · 57,000 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.42 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 6AUWR-6024Pwith ducted air handler AUH-6024HisenseAlso listed as AOH-60U3T24P5 tons · 57,000 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.46 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 7AM060FCMDCG1Samsung5 tons · 60,000 Btu/h · DuctedKeeps 85% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.04 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 8VPD060H6M-5PLennox5 tons · 60,000 Btu/h · DuctedKeeps 85% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 85% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.04 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.5 (HSPF2)
- Top 10%
- 927VNA360A*030*with ducted air handler FE5BNBD60L*+UICarrierAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAA5 tons · 58,000 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.18 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.0 (HSPF2)
- Good
- 103TXK2260AF00HAATraneAlso listed as 3TVHS060SF000AA5 tons · 60,000 Btu/h · DuctedKeeps 82% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 11.0 (HSPF2)
- Top 10%
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, 5 tons and up
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 53%+
- Great
- 67%+
- Top 10%
- 72%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 2.00+
- Great
- 2.10+
- Top 10%
- 2.20+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 7.2+
- Great
- 9.0+
- Top 10%
- 9.5+
Next steps
Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.
Open the advanced view