- Insights
- Cold-climate picks
Both views use the same certified data. This device remembers your choice.
Top cold-climate picks by size
The heat pumps of one size and type that hold up best when it is 5°F outside. Each pick shows its score and the three ratings behind it.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
Top cold-climate picks, ducted up to 1.5 tons
1,486 of 1,964 models in this size class qualify. 432 keep less than 70% of their heat at 5°F and 43 have no 5°F heat output rating, so they cannot qualify.
- 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3CarrierAlso sold as Midea 37MAHAQ06AA3, Midea D5CSHAH06AAK, MDV MOX230-06HFN10-M1X, Arcoaire D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 2DRA1H06S2Awith ducted air handler DRADL0612F2ADurastar0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 3MO1HS-H06B-2Awith ducted air handler MDLHU-H06B-2AMidea0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 4BMS626HHYCwith ducted air handler BMC6LCDBlueRidge0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 5CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MSCooper&Hunter0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 6ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-IRheem (sold as Mainline)0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 7W5HD606K1X1Awith ducted air handler W5GLW06K1AAACarrier (sold as Grandaire)0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 98% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.41 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 13.8 (HSPF2)
- Top 10%
- 837MUHAQ18AA3with indoor coil DM36A3J+TDR and furnace 8(0,1)*SB36070M17Carrier (sold as Bryant Heating and Cooling Systems)1.5 tons · 16,800 Btu/h · DuctedKeeps 95% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 95% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 3.00 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.8 (HSPF2)
- Top 10%
- 95TWV0X24A1with indoor coil D(A,C,E)36C3J+TDR and furnace S8V2B060M4PCBTrane1.5 tons · 19,800 Btu/h · DuctedKeeps 122% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 122% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.99 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
- 10RD18AY24AJVCwith indoor coil D(A,C,E)36A3J+TDR and furnace R951V0403A17UHRheem1.5 tons · 20,200 Btu/h · DuctedKeeps 116% of its heat at 5°FMeets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 116% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.60 (COP at 5°F)
- Top 10%
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What good looks like: ducted, up to 1.5 tons
Capacity at 5°F vs 47°F
Heating power kept at 5°F
How much of its mild-weather heating power the unit still delivers at 5°F.
- Good
- 74%+
- Great
- 90%+
- Top 10%
- 100%+
COP at 5°F
Efficiency on a 5°F day
How much heat the unit makes from each unit of electricity when it is 5°F outside.
- Good
- 1.90+
- Great
- 2.10+
- Top 10%
- 2.32+
HSPF2
Winter-long heating efficiency
Heating efficiency over a whole winter, measured with a federal test.
- Good
- 9.2+
- Great
- 10.0+
- Top 10%
- 10.6+
Next steps
Advanced view: all-sizes boards, peer percentiles for each qualifier, heating and cooling sub-scores, charts of every model in each size class, EER2 and heat output boards.
Open the advanced view