Skip to content

Compare certified heat pump ratings by size

Official test ratings for 13,566 central and mini-split heat pumps. Each model is compared only with others of the same size and type.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

Rebate tiers and cold-weather output

  • 57%

    of models meet CEE 2025 Tier 1, the efficiency level many utility rebates use.

    7,762 of 13,566 models.

    See which ones

  • 72%

    of its 47°F heating output is what the typical heat pump still puts out at 5°F in the test.

    The best on this one rating keep all of it, or more.

    See them by size

  • 2.5%

    reach the CEE Advanced tier: full heating output and a COP of 2.1 or more at 5°F, and HSPF2 of 8.5 or more.

    About 1 in 40 models (337).

    See the cold-climate tier

Heating output as it gets colderIn the 5°F test, the typical ducted heat pump puts out 71% of its 47°F heating output, and the typical ductless one 66%.

Middle value (median) of the 6,291 models with cold-weather test results. Each model is measured against its own 47°F output, so sizes are not mixed. Source: NEEP cold-climate heat pump list.

Top cold-climate picks, ducted up to 1.5 tons

1,486 of 1,964 models in this size class qualify. 432 keep less than 70% of their heat at 5°F and 43 have no 5°F heat output rating, so they cannot qualify.

  1. 137MAHAQ06AA3with ducted air handler 45MBDAQ06XA3CarrierAlso sold as Midea 37MAHAQ06AA3, Midea D5CSHAH06AAK, MDV MOX230-06HFN10-M1X, Arcoaire D5CSHAH06AAK0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    13.8 (HSPF2)
    Top 10%
    93.6score / 100
  2. 2DRA1H06S2Awith ducted air handler DRADL0612F2ADurastar0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    13.8 (HSPF2)
    Top 10%
    93.6score / 100
  3. 3MO1HS-H06B-2Awith ducted air handler MDLHU-H06B-2AMidea0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    13.8 (HSPF2)
    Top 10%
    93.6score / 100
  4. 4BMS626HHYCwith ducted air handler BMC6LCDBlueRidge0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    13.8 (HSPF2)
    Top 10%
    93.6score / 100
  5. 5CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MSCooper&Hunter0.5 tons · 6,500 Btu/h · DuctedKeeps 98% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    2.41 (COP at 5°F)
    Top 10%
    Seasonal efficiency
    13.8 (HSPF2)
    Top 10%
    93.6score / 100

Top 10 cold-climate picks, ducted, up to 1.5 tons

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What good looks like: ducted, up to 1.5 tons

Good beats half of this size class, great is the top quarter, top is the top 10%. The thresholds come from this class’s own ratings.
  • Capacity at 5°F vs 47°F

    Heating power kept at 5°F

    How much of its mild-weather heating power the unit still delivers at 5°F.

    Good
    74%+
    Great
    90%+
    Top 10%
    100%+
  • COP at 5°F

    Efficiency on a 5°F day

    How much heat the unit makes from each unit of electricity when it is 5°F outside.

    Good
    1.90+
    Great
    2.10+
    Top 10%
    2.32+
  • HSPF2

    Winter-long heating efficiency

    Heating efficiency over a whole winter, measured with a federal test.

    Good
    9.2+
    Great
    10.0+
    Top 10%
    10.6+

What size is my system?

Tons and Btu

A heat pump’s size is its rated cooling output, in Btu per hour. Installers talk in tons: one ton is 12,000 Btu per hour, so a 3-ton unit is about 36,000.

Where to find yours: the nameplate sticker on the outdoor unit lists the model number. Many model numbers include the size in thousands of Btu, such as 24 (2 tons), 36 (3 tons) or 48 (4 tons). Your quote or AHRI certificate also lists it. Look up a model number

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Size classes used here

  • Up to 1.5 tonsunder 21,000 Btu/h
  • 2 tons21,000 to 26,999 Btu/h
  • 2.5 to 3 tons27,000 to 38,999 Btu/h
  • 3.5 to 4.5 tons39,000 to 56,999 Btu/h
  • 5 tons and up57,000 Btu/h and up

Ducted or ductless

A ducted (central) heat pump moves air through a home’s ducts. A ductless mini-split puts a small unit on the wall of each room. Mini-splits usually test higher (typical cooling rating 21.0 vs 16.0), partly because the test for ducted units includes pushing air through ducts, so the two are ranked separately.

Federal tax credit

Advanced view, for contractors, utilities and analysts: capacity and COP curves from 47°F to 5°F, every distribution, peer percentile, standards flow and data table behind this page.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter