Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ACIQ vs Friedrich heat pumps
Measured against models of the same size and duct type, ACIQ scores higher on 4 of the 6 ratings. ACIQ has 161 outdoor models, Friedrich has 117 outdoor models. ACIQ has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ACIQ
- Friedrich
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ACIQ | Friedrich |
|---|---|---|
| Efficiency index | 47% (higher)median — | 46% (higher)median — · 25th ranked |
| COP at 5°F | 48%median 1.94 | 58%median 2.10 · 9th ranked |
| Capacity retention at 5°F | 43%median 59% | 45%median 61% · 20th ranked |
| HSPF2 | 44% (higher)median 8.1 | 31% (higher)median 7.5 · 26th ranked |
| SEER2 | 45% (higher)median 16.0 | 36% (higher)median 15.2 · 26th ranked |
| EER2 | 50% (higher)median 11.1 | 39% (higher)median 10.6 · 26th ranked |
| Heating capacity at 5°F | 44% (higher)median 19,100 Btu/h | 39% (higher)median 15,600 Btu/h · 25th ranked |
| Outdoor models | 161 | 117 |
| AHRI certifications | 6,584 | 3,083 |
Share of models meeting each standard
| Standard | ACIQ | Friedrich |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 41%66 models | 37.6%44 models |
| CEE 2026 Tier 1 (Split ASHP) | 34.2%55 models | 37.6%44 models |
| CEE Advanced Tier (Split ASHP) | 1.2%2 models | 1.7%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.7%51 models | 31.6%37 models |
| DOE Cold Climate Heat Pump Challenge | 1.2%2 models | 1.7%2 models |
| ENERGY STAR Cold Climate | 19.3%31 models | 28.2%33 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ACIQ
- Friedrich
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ACIQ | Friedrich |
|---|---|---|
| Ducted, up to 1.5 tons | 14 · index 50% | 21 · index 27% |
| Ducted, 2 tons | 23 · index 45% | 16 · index 45% |
| Ducted, 2.5–3 tons | 40 · index 43% | 22 · index 52% |
| Ducted, 3.5–4.5 tons | 52 · index 46% | 28 · index 47% |
| Ducted, 5 tons and up | 5 · index 48% | 7 · index — |
| Non-ducted, up to 1.5 tons | 22 · index 52% | 19 · index 55% |
| Non-ducted, 2 tons | 6 · index 52% | 6 · index 47% |
| Non-ducted, 2.5–3 tons | 14 · index 51% | 6 · index 61% |
| Non-ducted, 3.5–4.5 tons | 7 · index 48% | 1 · index 45% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ACIQCold-climate score, best model | FriedrichCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM9 of 14 models qualify · AHRI 213433248 | 55.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 22 models qualify · AHRI 207825541 | 74.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 41 models qualify · AHRI 210857321 | 80.6(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class) (higher)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB11 of 52 models qualify · AHRI 210857322 | 76.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028 |
| Ducted, 5 tons and up | None on this board (0 of 5 models qualify) | None on this board (0 of 7 models qualify) |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC16 of 22 models qualify · AHRI 210857314 | 78.4(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197 |
| Non-ducted, 2 tons | 85.4(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB4 of 6 models qualify · AHRI 207825544 | 72.0(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B6 of 14 models qualify · AHRI 207825582 | 77.2(50 is the typical model of its size class)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421 |
| Non-ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class) (higher)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 7 models qualify · AHRI 210857326 | 41.9(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 205141513 |
All-around best
| Size and duct type | ACIQAll-around score, best model | FriedrichAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.2(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB14 of 14 models have all five ratings · AHRI 207825538 | 57.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198 |
| Ducted, 2 tons | 80.1(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB23 of 23 models have all five ratings · AHRI 207825541 | 83.5(50 is the typical model of its size class) (higher)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710 |
| Ducted, 2.5–3 tons | 75.4(50 is the typical model of its size class)ES-27Z-M3B40 of 40 models have all five ratings · AHRI 210857387 | 86.1(50 is the typical model of its size class) (higher)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B50 of 53 models have all five ratings · AHRI 207825586 | 80.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153 |
| Ducted, 5 tons and up | 54.0(50 is the typical model of its size class)H4H5S60*K*AAA*with ducted air handler FJMA4*60L*D4 of 4 models have all five ratings · AHRI 213069077 | 70.1(50 is the typical model of its size class) (higher)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738 |
| Non-ducted, up to 1.5 tons | 92.0(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC22 of 22 models have all five ratings · AHRI 210857314 | 85.1(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 207825534 | 67.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246 |
| Non-ducted, 2.5–3 tons | 82.8(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B11 of 14 models have all five ratings · AHRI 207825582 | 69.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247 |
| Non-ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B7 of 7 models have all five ratings · AHRI 207825585 | 44.5(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ACIQ | Friedrich |
|---|---|---|
| COP at 5°F | beats 93% · 2.57R4H5S30*K*AAA*Ducted, 2.5–3 tons | beats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 140%HVH837GKA2*Ducted, 2.5–3 tons | beats 100% · 105%FRP18AZ48AJVCDucted, 3.5–4.5 tons |
| HSPF2 | beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5–4.5 tons | beats 83% · 9.5FPHFR36A3ADucted, 2.5–3 tons |
| SEER2 | beats 99% · 24.6ES-27Z-M3BNon-ducted, 2.5–3 tons | beats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons |
| EER2 | beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tons | beats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5–4.5 tons | beats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5–3 tons |