Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ADP vs STEALTH heat pumps
Measured against models of the same size and duct type, ADP and STEALTH split the 6 ratings 3–3. ADP has 41 outdoor models, STEALTH has 42 outdoor models. ADP and STEALTH have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ADP
- STEALTH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ADP | STEALTH |
|---|---|---|
| Efficiency index | 52%median — | 57%median — |
| COP at 5°F | 46% (higher)median 1.90 | 45% (higher)median 1.93 |
| Capacity retention at 5°F | 73% (higher)median 83% | 61% (higher)median 80% |
| HSPF2 | 64%median 8.6 | 69%median 9.5 |
| SEER2 | 57%median 16.0 | 61%median 18.3 |
| EER2 | 30%median 10.0 | 45%median 10.5 |
| Heating capacity at 5°F | 70% (higher)median 27,000 Btu/h | 62% (higher)median 22,765 Btu/h |
| Outdoor models | 41 | 42 |
| AHRI certifications | 471 | 119 |
Share of models meeting each standard
| Standard | ADP | STEALTH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 53.7%22 models | 61.9%26 models |
| CEE 2026 Tier 1 (Split ASHP) | 53.7%22 models | 52.4%22 models |
| CEE Advanced Tier (Split ASHP) | 2.4%1 models | 2.4%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 73.2%30 models | 47.6%20 models |
| DOE Cold Climate Heat Pump Challenge | 2.4%1 models | 2.4%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 50%21 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ADP
- STEALTH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ADP | STEALTH |
|---|---|---|
| Ducted, up to 1.5 tons | 3 · index 46% | 8 · index 60% |
| Ducted, 2 tons | 12 · index 50% | 3 · index 69% |
| Ducted, 2.5–3 tons | 14 · index 52% | 11 · index 54% |
| Ducted, 3.5–4.5 tons | 11 · index 56% | 10 · index 54% |
| Ducted, 5 tons and up | 1 · index 61% | None |
| Non-ducted, up to 1.5 tons | None | 10 · index 58% |
| Non-ducted, 2 tons | None | 2 · index 50% |
| Non-ducted, 2.5–3 tons | None | 9 · index 59% |
| Non-ducted, 3.5–4.5 tons | None | 6 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ADPCold-climate score, best model | STEALTHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 62.3(50 is the typical model of its size class)DLCURAH18ABKwith ducted air handler H,GE31930+TD3 of 3 models qualify · AHRI 213613872 | 86.9(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM7 of 8 models qualify · AHRI 213433305 |
| Ducted, 2 tons | 75.3(50 is the typical model of its size class)4TXD2036A10NU**with ducted air handler F,PE*G3493011 of 11 models qualify · AHRI 212396553 | 79.4(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB3 of 3 models qualify · AHRI 212316167 |
| Ducted, 2.5–3 tons | 79.8(50 is the typical model of its size class)DIRM-36MAGICPRO20-OUwith ducted air handler HG8J936+TD13 of 15 models qualify · AHRI 212897484 | 79.9(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB6 of 11 models qualify · AHRI 212316191 |
| Ducted, 3.5–4.5 tons | 78.0(50 is the typical model of its size class)BOVA-60HDN1-M20Gwith indoor coil HE35948 and furnace BGH96M100D5A9 of 11 models qualify · AHRI 212361477 | 86.4(50 is the typical model of its size class) (higher)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB6 of 10 models qualify · AHRI 212316192 |
| Ducted, 5 tons and up | 74.1(50 is the typical model of its size class)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models qualify · AHRI 211289597 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 89.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC5 of 10 models qualify · AHRI 212316184 |
| Non-ducted, 2 tons | No models in this size class | 85.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB1 of 2 models qualify · AHRI 212316170 |
| Non-ducted, 2.5–3 tons | No models in this size class | 79.3(50 is the typical model of its size class)ACIQ-36Z-HH-M4B3 of 9 models qualify · AHRI 212316177 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB4 of 6 models qualify · AHRI 212316196 |
All-around best
| Size and duct type | ADPAll-around score, best model | STEALTHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 49.9(50 is the typical model of its size class)DLCURAH18ABKwith ducted air handler H,GE31930+TD3 of 3 models have all five ratings · AHRI 213613872 | 85.2(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB8 of 8 models have all five ratings · AHRI 212316164 |
| Ducted, 2 tons | 83.7(50 is the typical model of its size class) (higher)SL25XPV-024-230A**with indoor coil LP36/37R9 and furnace EL297UH070XV36B13 of 13 models have all five ratings · AHRI 213360216 | 80.1(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB3 of 3 models have all five ratings · AHRI 212316167 |
| Ducted, 2.5–3 tons | 77.4(50 is the typical model of its size class) (higher)SL25XPV-036-230A**with indoor coil L*35/36U9 and furnace EL297UH110XV48C13 of 13 models have all five ratings · AHRI 213360276 | 75.4(50 is the typical model of its size class)ES-27Z-M3B11 of 11 models have all five ratings · AHRI 212316210 |
| Ducted, 3.5–4.5 tons | 82.6(50 is the typical model of its size class) (higher)SL25XPV-048-230A**with indoor coil LH42/62W9 and furnace EL297UH110XV60C11 of 11 models have all five ratings · AHRI 213361090 | 82.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B9 of 9 models have all five ratings · AHRI 212316181 |
| Ducted, 5 tons and up | 60.6(50 is the typical model of its size class) (higher)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models have all five ratings · AHRI 211289597 | 41.7(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433299 |
| Non-ducted, up to 1.5 tons | No models in this size class | 92.0(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC10 of 10 models have all five ratings · AHRI 212316184 |
| Non-ducted, 2 tons | No models in this size class | 84.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB2 of 2 models have all five ratings · AHRI 212316160 |
| Non-ducted, 2.5–3 tons | No models in this size class | 82.8(50 is the typical model of its size class)ACIQ-36Z-HH-M4B7 of 9 models have all five ratings · AHRI 212316177 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 77.9(50 is the typical model of its size class)ACIQ-48Z-HH-M5B6 of 6 models have all five ratings · AHRI 212316180 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ADP | STEALTH |
|---|---|---|
| COP at 5°F | beats 90% · 2.50BOVA-60HDN1-M20GDucted, 3.5–4.5 tons | beats 91% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 91%AC060BXUPCHDucted, 5 tons and up | beats 95% · 113%ACIQ-06ZPL-HP230BNon-ducted, up to 1.5 tons |
| HSPF2 | beats 96% · 9.0AC060BXUPCHDucted, 5 tons and up | beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5–4.5 tons |
| SEER2 | beats 100% · 23.0SL25XPV-024-230A**Ducted, 2 tons | beats 99% · 24.6ES-27Z-M3BNon-ducted, 2.5–3 tons |
| EER2 | beats 100% · 14.5SL25XPV-024-230A**Ducted, 2 tons | beats 98% · 16.2ACIQ-09ZPL-HP230BNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 32,800 Btu/hWSEHV2436RA1-CAlso listed as WSEHV2436RA1-NDucted, 2 tons | beats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5–4.5 tons |