Skip to content

AI AIR CONDITIONING vs HAIER heat pumps

Measured against models of the same size and duct type, AI AIR CONDITIONING scores higher on 6 of the 6 ratings. AI AIR CONDITIONING has 48 outdoor models, HAIER has 48 outdoor models. AI AIR CONDITIONING and HAIER have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AI AIR CONDITIONING and HAIER on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AI AIR CONDITIONING scores higher on 6 of the 6 ratings.
  • AI AIR CONDITIONING
  • HAIER
  • Other ranked manufacturers
AI AIR C…HAIER

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAI AIR CONDITIONINGHAIER
Efficiency index60% (higher)median —43% (higher)median —
COP at 5°F49% (higher)median 1.9029% (higher)median 1.80
Capacity retention at 5°F57% (higher)median 72%46% (higher)median 71%
HSPF270% (higher)median 9.656% (higher)median 9.5
SEER268% (higher)median 21.046% (higher)median 20.0
EER256% (higher)median 12.039% (higher)median 12.0
Heating capacity at 5°F56% (higher)median 19,471 Btu/h49% (higher)median 15,050 Btu/h
Outdoor models4848
AHRI certifications7099

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAI AIR CONDITIONINGHAIER
CEE 2025 Tier 1 (Split ASHP)79.2%38 models54.2%26 models
CEE 2026 Tier 1 (Split ASHP)72.9%35 models54.2%26 models
CEE Advanced Tier (Split ASHP)0%0 models4.2%2 models
Xcel Energy Colorado cold-climate ASHP (2025)56.3%27 models45.8%22 models
DOE Cold Climate Heat Pump Challenge0%0 models4.2%2 models
ENERGY STAR Cold Climate56.3%27 models33.3%16 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • AI AIR CONDITIONING
  • HAIER
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAI AIR CONDITIONINGHAIER
Ducted, up to 1.5 tons4 · index 54%6 · index 36%
Ducted, 2 tons2 · index 59%5 · index 42%
Ducted, 2.5–3 tons8 · index 62%6 · index 38%
Ducted, 3.5–4.5 tons7 · index 60%5 · index 34%
Ducted, 5 tons and up1 · index 42%None
Non-ducted, up to 1.5 tons20 · index 64%25 · index 55%
Non-ducted, 2 tons4 · index 62%9 · index 46%
Non-ducted, 2.5–3 tons8 · index 58%6 · index 32%
Non-ducted, 3.5–4.5 tons4 · index 51%4 · index 15%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAI AIR CONDITIONINGCold-climate score, best modelHAIERCold-climate score, best model
Ducted, up to 1.5 tons60.4(50 is the typical model of its size class) (higher)AUO18-18N1-M3Hwith ducted air handler AUH2-18N1-BM3E3 of 4 models qualify · AHRI 21376992252.9(50 is the typical model of its size class)2U20EH2HD**4 of 6 models qualify · AHRI 210151026
Ducted, 2 tons66.5(50 is the typical model of its size class) (higher)AUO18-24N1-M3Hwith ducted air handler AUH2-24N1-BM3E2 of 2 models qualify · AHRI 21376992357.0(50 is the typical model of its size class)3U24EH2HD**2 of 5 models qualify · AHRI 210082199
Ducted, 2.5–3 tons80.4(50 is the typical model of its size class) (higher)A3MO22-27N1-M1H5 of 8 models qualify · AHRI 21376995662.0(50 is the typical model of its size class)4U36EH2HD**2 of 6 models qualify · AHRI 210151027
Ducted, 3.5–4.5 tons74.9(50 is the typical model of its size class) (higher)A5MO22-48N1-M1H4 of 7 models qualify · AHRI 21376996253.6(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD1 of 5 models qualify · AHRI 211729105
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons86.0(50 is the typical model of its size class)AO24-09N1-M1Hwith ductless indoor unit AW25-09N1-M112 of 20 models qualify · AHRI 21376993895.5(50 is the typical model of its size class) (higher)1U12EH2VHE*with ductless indoor unit AW12EH2VHD15 of 25 models qualify · AHRI 206389351
Non-ducted, 2 tons84.5(50 is the typical model of its size class) (higher)AO29-24N1-M1Hwith ductless indoor unit AW29-24N1-M13 of 4 models qualify · AHRI 21376995061.1(50 is the typical model of its size class)3U24EH2HD**4 of 9 models qualify · AHRI 210082198
Non-ducted, 2.5–3 tons87.0(50 is the typical model of its size class) (higher)A4MO22-36N1-M1H4 of 8 models qualify · AHRI 21376995867.0(50 is the typical model of its size class)4U36EH2HD**3 of 6 models qualify · AHRI 210082201
Non-ducted, 3.5–4.5 tons80.5(50 is the typical model of its size class) (higher)A5MO22-48N1-M1H2 of 4 models qualify · AHRI 21376996119.2(50 is the typical model of its size class)1U4248LP2HD**with ductless indoor unit USYL42UCDD1 of 4 models qualify · AHRI 211744605

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAI AIR CONDITIONINGAll-around score, best modelHAIERAll-around score, best model
Ducted, up to 1.5 tons63.4(50 is the typical model of its size class) (higher)AUO18-18N1-M3Hwith ducted air handler AUH2-18N1-BM3E4 of 4 models have all five ratings · AHRI 21376992244.7(50 is the typical model of its size class)1U09EH2HE**with ducted air handler USYM09UCDSA5 of 6 models have all five ratings · AHRI 212409472
Ducted, 2 tons65.8(50 is the typical model of its size class) (higher)AUO18-24N1-M3Hwith ducted air handler AUH2-24N1-BM3E2 of 2 models have all five ratings · AHRI 21376992353.8(50 is the typical model of its size class)3U24EH2HD**3 of 5 models have all five ratings · AHRI 210082199
Ducted, 2.5–3 tons83.7(50 is the typical model of its size class) (higher)A4MO22-36N1-M1H8 of 8 models have all five ratings · AHRI 21376995944.5(50 is the typical model of its size class)4U36EH2HD**4 of 6 models have all five ratings · AHRI 210151027
Ducted, 3.5–4.5 tons82.0(50 is the typical model of its size class) (higher)A5MO22-48N1-M1H7 of 7 models have all five ratings · AHRI 21376996238.5(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD4 of 5 models have all five ratings · AHRI 211729105
Ducted, 5 tons and up41.7(50 is the typical model of its size class)AUO17-60N1-M3with ducted air handler AUH2-60N1-DM3E1 of 1 models have all five ratings · AHRI 214296082No models in this size class
Non-ducted, up to 1.5 tons88.8(50 is the typical model of its size class)AO29-09N1-M1Hwith ductless indoor unit AW29-09N1-M120 of 20 models have all five ratings · AHRI 21376994795.2(50 is the typical model of its size class) (higher)1U09EH2VHE*with ductless indoor unit AW09EH2VHD22 of 25 models have all five ratings · AHRI 206445819
Non-ducted, 2 tons84.3(50 is the typical model of its size class) (higher)AO29-24N1-M1Hwith ductless indoor unit AW29-24N1-M14 of 4 models have all five ratings · AHRI 21376995059.8(50 is the typical model of its size class)3U24MS2HD**7 of 9 models have all five ratings · AHRI 207698998
Non-ducted, 2.5–3 tons76.8(50 is the typical model of its size class) (higher)A4MO22-36N1-M1H8 of 8 models have all five ratings · AHRI 21376995848.7(50 is the typical model of its size class)4U36EH2HD**5 of 6 models have all five ratings · AHRI 210082201
Non-ducted, 3.5–4.5 tons73.8(50 is the typical model of its size class) (higher)A5MO22-48N1-M1H4 of 4 models have all five ratings · AHRI 21376996118.3(50 is the typical model of its size class)5U42MS2HD**4 of 4 models have all five ratings · AHRI 210404027

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAI AIR CONDITIONINGHAIER
COP at 5°Fbeats 96% · 2.22AO24-24N1-M1HNon-ducted, 2 tonsbeats 93% · 2.311U12EH2VHE*Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 96% · 101%A3MO22-27N1-M1HDucted, 2.5–3 tonsbeats 97% · 120%1U09EH2VHE*Non-ducted, up to 1.5 tons
HSPF2beats 100% · 14.5AO29-12N1-M1HNon-ducted, up to 1.5 tonsbeats 99% · 14.01U09EH2VHE*Non-ducted, up to 1.5 tons
SEER2beats 99% · 29.0AO29-09N1-M1HNon-ducted, up to 1.5 tonsbeats 100% · 30.01U09EH2VHE*Non-ducted, up to 1.5 tons
EER2beats 99% · 16.5AO29-09N1-M1HNon-ducted, up to 1.5 tonsbeats 97% · 16.01U09EH2VHE*Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hA2MO22-18N1-M1HNon-ducted, up to 1.5 tonsbeats 94% · 18,500 Btu/h2U20EH2HD**Non-ducted, up to 1.5 tons

More comparisons