Skip to content

AireForce vs KERR heat pumps

Measured against models of the same size and duct type, KERR scores higher on 6 of the 6 ratings. AireForce has 23 outdoor models, KERR has 24 outdoor models. AireForce and KERR have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AireForce and KERR on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KERR scores higher on 6 of the 6 ratings.
  • AireForce
  • KERR
  • Other ranked manufacturers
AireForceKERR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAireForceKERR
Efficiency index45%median —66%median —
COP at 5°F32%median 1.8149%median 1.95
Capacity retention at 5°F65%median 77%78%median 91%
HSPF237%median 8.576%median 10.0
SEER240%median 17.568%median 20.0
EER243%median 11.058%median 11.9
Heating capacity at 5°F63%median 19,800 Btu/h75%median 25,000 Btu/h
Outdoor models2324
AHRI certifications5490

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAireForceKERR
CEE 2025 Tier 1 (Split ASHP)52.2%12 models83.3%20 models
CEE 2026 Tier 1 (Split ASHP)52.2%12 models83.3%20 models
CEE Advanced Tier (Split ASHP)0%0 models8.3%2 models
Xcel Energy Colorado cold-climate ASHP (2025)56.5%13 models79.2%19 models
DOE Cold Climate Heat Pump Challenge0%0 models8.3%2 models
ENERGY STAR Cold Climate34.8%8 models87.5%21 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • AireForce
  • KERR
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAireForceKERR
Ducted, up to 1.5 tons3 · index 31%6 · index 60%
Ducted, 2 tons3 · index 53%3 · index 71%
Ducted, 2.5–3 tons4 · index 52%5 · index 67%
Ducted, 3.5–4.5 tons3 · index 63%4 · index 63%
Non-ducted, up to 1.5 tons8 · index 28%7 · index 68%
Non-ducted, 2 tons2 · index 57%3 · index 79%
Non-ducted, 2.5–3 tons5 · index 60%6 · index 64%
Non-ducted, 3.5–4.5 tonsNone2 · index 65%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAireForceCold-climate score, best modelKERRCold-climate score, best model
Ducted, up to 1.5 tons35.6(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 3 models qualify · AHRI 21163519774.9(50 is the typical model of its size class) (higher)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models qualify · AHRI 210568255
Ducted, 2 tons50.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-11 of 2 models qualify · AHRI 21163519879.4(50 is the typical model of its size class) (higher)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models qualify · AHRI 206347321
Ducted, 2.5–3 tons55.3(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH**-36MSK4DH14 of 5 models qualify · AHRI 20672440579.9(50 is the typical model of its size class) (higher)A-KMH36QV-1A5 of 5 models qualify · AHRI 217169741
Ducted, 3.5–4.5 tons58.1(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 3 models qualify · AHRI 20672440674.9(50 is the typical model of its size class) (higher)A-KMH48PV-14 of 4 models qualify · AHRI 207657607
Non-ducted, up to 1.5 tons73.1(50 is the typical model of its size class)GXH18(5.3)FMK4DH-17 of 8 models qualify · AHRI 21163519289.3(50 is the typical model of its size class) (higher)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models qualify · AHRI 207657393
Non-ducted, 2 tons76.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models qualify · AHRI 21163519386.1(50 is the typical model of its size class) (higher)A-KMH24SV-1with ductless indoor unit C-VMH24CV-13 of 3 models qualify · AHRI 207657400
Non-ducted, 2.5–3 tons73.7(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models qualify · AHRI 21163519690.9(50 is the typical model of its size class) (higher)A-KMH36QV-1A3 of 6 models qualify · AHRI 217169740
Non-ducted, 3.5–4.5 tonsNo models in this size class76.2(50 is the typical model of its size class)A-KMH48PV-12 of 2 models qualify · AHRI 207657606

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAireForceAll-around score, best modelKERRAll-around score, best model
Ducted, up to 1.5 tons31.2(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 3 models have all five ratings · AHRI 21163519785.2(50 is the typical model of its size class) (higher)A-KMH09SV-1with ducted air handler B-KMH09DU-16 of 6 models have all five ratings · AHRI 210568255
Ducted, 2 tons60.8(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH24-**MSK4DH12 of 3 models have all five ratings · AHRI 20672440480.1(50 is the typical model of its size class) (higher)A-KMH24SU-1Awith ducted air handler B-KMH24DU-1Also listed as A-KMH24SV-13 of 3 models have all five ratings · AHRI 206347321
Ducted, 2.5–3 tons53.1(50 is the typical model of its size class)GXH30(8.8)FMK4DH-13 of 4 models have all five ratings · AHRI 21163519983.7(50 is the typical model of its size class) (higher)A-KMH36QV-1A5 of 5 models have all five ratings · AHRI 217169741
Ducted, 3.5–4.5 tons63.3(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 3 models have all five ratings · AHRI 20672440682.0(50 is the typical model of its size class) (higher)A-KMH48PV-14 of 4 models have all five ratings · AHRI 207657607
Non-ducted, up to 1.5 tons58.0(50 is the typical model of its size class)GXH18(5.3)FMK4DH-18 of 8 models have all five ratings · AHRI 21163519292.0(50 is the typical model of its size class) (higher)A-KMH06SV-1with ductless indoor unit B-KMH06SV-17 of 7 models have all five ratings · AHRI 207657393
Non-ducted, 2 tons71.5(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models have all five ratings · AHRI 21163519384.3(50 is the typical model of its size class) (higher)A-KMH24SV-1with ductless indoor unit B-KMH24SV-1Also listed as A-KMH24SU-13 of 3 models have all five ratings · AHRI 207657397
Non-ducted, 2.5–3 tons70.2(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models have all five ratings · AHRI 21163519686.4(50 is the typical model of its size class) (higher)A-KMH36QV-1A5 of 6 models have all five ratings · AHRI 217169740
Non-ducted, 3.5–4.5 tonsNo models in this size class77.9(50 is the typical model of its size class)A-KMH48PV-12 of 2 models have all five ratings · AHRI 207657606

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAireForceKERR
COP at 5°Fbeats 89% · 2.21GXH18(5.3)FMK4DH-1Non-ducted, up to 1.5 tonsbeats 91% · 2.21A-KMH24SV-1Also listed as A-KMH24SU-1Non-ducted, 2 tons
Capacity retention at 5°Fbeats 85% · 89%GXH30(8.8)FMK4DH-1Ducted, 2.5–3 tonsbeats 98% · 112%A-KCD36SA-1Ducted, 2.5–3 tons
HSPF2beats 82% · 10.0GXH30(8.8)FMK4DH-1Non-ducted, 2.5–3 tonsbeats 98% · 13.6A-KMH06SV-1Non-ducted, up to 1.5 tons
SEER2beats 83% · 24.0GXH12(3.5)LSK4DH2Non-ducted, up to 1.5 tonsbeats 99% · 20.9A-KMH48PV-1Ducted, 3.5–4.5 tons
EER2beats 84% · 12.5GXH30(8.8)FMK4DH-1Non-ducted, 2.5–3 tonsbeats 98% · 16.2A-KMH09SV-1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 86% · 14,500 Btu/hGXH18(5.3)LSK4DH2Non-ducted, up to 1.5 tonsbeats 99% · 42,000 Btu/hA-KCD36SA-1Ducted, 2.5–3 tons

More comparisons