Skip to content

AIRTEMP vs TUTTOKOOL heat pumps

Measured against models of the same size and duct type, AIRTEMP scores higher on 5 of the 6 ratings. AIRTEMP has 25 outdoor models, TUTTOKOOL has 25 outdoor models. AIRTEMP and TUTTOKOOL have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIRTEMP and TUTTOKOOL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AIRTEMP scores higher on 5 of the 6 ratings.
  • AIRTEMP
  • TUTTOKOOL
  • Other ranked manufacturers
AIRTEMPTUTTOKOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIRTEMPTUTTOKOOL
Efficiency index45% (higher)median —17% (higher)median —
COP at 5°F32% (higher)median 1.812% (higher)median 1.40
Capacity retention at 5°F65% (higher)median 77%4% (higher)median 36%
HSPF237% (higher)median 8.518% (higher)median 7.5
SEER238% (higher)median 17.014% (higher)median 14.3
EER244%median 11.058%median 11.5
Heating capacity at 5°F63% (higher)median 19,800 Btu/h5% (higher)median 13,300 Btu/h
Outdoor models2525
AHRI certifications58114

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIRTEMPTUTTOKOOL
CEE 2025 Tier 1 (Split ASHP)48%12 models0%0 models
CEE 2026 Tier 1 (Split ASHP)48%12 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)52%13 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate32%8 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • AIRTEMP
  • TUTTOKOOL
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIRTEMPTUTTOKOOL
Ducted, up to 1.5 tons2 · index 31%2 · index —
Ducted, 2 tons3 · index 53%4 · index 12%
Ducted, 2.5–3 tons6 · index 52%7 · index 16%
Ducted, 3.5–4.5 tons4 · index 63%10 · index 20%
Ducted, 5 tons and upNone2 · index 19%
Non-ducted, up to 1.5 tons8 · index 28%None
Non-ducted, 2 tons2 · index 57%None
Non-ducted, 2.5–3 tons5 · index 60%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIRTEMPCold-climate score, best modelTUTTOKOOLCold-climate score, best model
Ducted, up to 1.5 tons35.6(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models qualify · AHRI 210276818None on this board (0 of 2 models qualify)
Ducted, 2 tons50.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-11 of 2 models qualify · AHRI 210276819None on this board (0 of 4 models qualify)
Ducted, 2.5–3 tons55.3(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH**-36MSK4DH14 of 7 models qualify · AHRI 206724409None on this board (0 of 7 models qualify)
Ducted, 3.5–4.5 tons58.1(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models qualify · AHRI 206724410None on this board (0 of 10 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons73.1(50 is the typical model of its size class)GXH18(5.3)FMK4DH-17 of 8 models qualify · AHRI 210276805No models in this size class
Non-ducted, 2 tons76.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models qualify · AHRI 210276806No models in this size class
Non-ducted, 2.5–3 tons73.7(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models qualify · AHRI 210276804No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIRTEMPAll-around score, best modelTUTTOKOOLAll-around score, best model
Ducted, up to 1.5 tons31.2(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models have all five ratings · AHRI 210276818None on this board (0 of 2 models have all five ratings)
Ducted, 2 tons60.8(50 is the typical model of its size class) (higher)GXH24-36MSK4DHwith ducted air handler GMH24-**MSK4DH12 of 3 models have all five ratings · AHRI 20672440812.4(50 is the typical model of its size class)APH3024E100A2 of 4 models have all five ratings · AHRI 214717114
Ducted, 2.5–3 tons53.1(50 is the typical model of its size class) (higher)GXH30(8.8)FMK4DH-13 of 6 models have all five ratings · AHRI 21027682017.3(50 is the typical model of its size class)APH3036E100A3 of 7 models have all five ratings · AHRI 214717150
Ducted, 3.5–4.5 tons63.3(50 is the typical model of its size class) (higher)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models have all five ratings · AHRI 20672441021.5(50 is the typical model of its size class)APH3048E100A3 of 10 models have all five ratings · AHRI 214717148
Ducted, 5 tons and upNo models in this size class19.3(50 is the typical model of its size class)APH3060E100AAlso listed as APHM3060100A2 of 2 models have all five ratings · AHRI 214717149
Non-ducted, up to 1.5 tons58.0(50 is the typical model of its size class)GXH18(5.3)FMK4DH-18 of 8 models have all five ratings · AHRI 210276805No models in this size class
Non-ducted, 2 tons71.5(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models have all five ratings · AHRI 210276806No models in this size class
Non-ducted, 2.5–3 tons70.2(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models have all five ratings · AHRI 210276804No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIRTEMPTUTTOKOOL
COP at 5°Fbeats 89% · 2.21GXH18(5.3)FMK4DH-1Non-ducted, up to 1.5 tonsbeats 4% · 1.40APH3060E100AAlso listed as APHM3060100ADucted, 5 tons and up
Capacity retention at 5°Fbeats 85% · 89%GXH30(8.8)FMK4DH-1Ducted, 2.5–3 tonsbeats 5% · 38%APH3060E100AAlso listed as APHM3060100ADucted, 5 tons and up
HSPF2beats 82% · 10.0GXH36(10.6)FMK4DH-1Non-ducted, 2.5–3 tonsbeats 39% · 7.8AHP5042E1000ADucted, 3.5–4.5 tons
SEER2beats 83% · 24.0GXH12(3.5)LSK4DH2Non-ducted, up to 1.5 tonsbeats 46% · 16.0AHP5030E1000ADucted, 2.5–3 tons
EER2beats 84% · 12.5GXH30(8.8)FMK4DH-1Non-ducted, 2.5–3 tonsbeats 82% · 12.0AHP5042E1000ADucted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 86% · 14,500 Btu/hGXH18(5.3)LSK4DH2Non-ducted, up to 1.5 tonsbeats 11% · 21,600 Btu/hAPH3060E100AAlso listed as APHM3060100ADucted, 5 tons and up

More comparisons