Skip to content

APLUS vs CONTINENTAL heat pumps

Measured against models of the same size and duct type, CONTINENTAL scores higher on 3 of the 6 ratings. APLUS has 5 outdoor models, CONTINENTAL has 12 outdoor models. APLUS and CONTINENTAL have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
APLUS and CONTINENTAL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CONTINENTAL scores higher on 3 of the 6 ratings.
  • APLUS
  • CONTINENTAL
  • Other ranked manufacturers
APLUSCONTINEN…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAPLUSCONTINENTAL
Efficiency index—median —67%median —
COP at 5°F—median —47%median 1.83
Capacity retention at 5°F—median —74%median 88%
HSPF221%median 7.573%median 9.8
SEER213%median 14.372%median 21.3
EER251%median 11.568%median 12.5
Heating capacity at 5°F—median —72%median 22,000 Btu/h
Outdoor models512
AHRI certifications959

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAPLUSCONTINENTAL
CEE 2025 Tier 1 (Split ASHP)0%0 models100%12 models
CEE 2026 Tier 1 (Split ASHP)0%0 models100%12 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models100%12 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models83.3%10 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • APLUS
  • CONTINENTAL
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAPLUSCONTINENTAL
Ducted, up to 1.5 tons1 · index —None
Ducted, 2 tons2 · index —2 · index 50%
Ducted, 2.5–3 tons2 · index —1 · index 74%
Ducted, 3.5–4.5 tonsNone2 · index 63%
Non-ducted, up to 1.5 tonsNone4 · index 73%
Non-ducted, 2 tonsNone2 · index 76%
Non-ducted, 2.5–3 tonsNone2 · index 67%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAPLUSCold-climate score, best modelCONTINENTALCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)No models in this size class
Ducted, 2 tonsNone on this board (0 of 2 models qualify)No models in this size class
Ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)65.0(50 is the typical model of its size class)CDHAM-28-O3 of 3 models qualify · AHRI 213386542
Ducted, 3.5–4.5 tonsNo models in this size class58.1(50 is the typical model of its size class)CS18HV48A60with ducted air handler CPFX48AAlso listed as WSEHV4860RA1-C2 of 2 models qualify · AHRI 207335558
Non-ducted, up to 1.5 tonsNo models in this size class77.8(50 is the typical model of its size class)CDHAS22-12-Owith ductless indoor unit CDHAS22-12-I4 of 4 models qualify · AHRI 213386538
Non-ducted, 2 tonsNo models in this size class84.5(50 is the typical model of its size class)CDHAS26-24-Owith ductless indoor unit CDHAS26-24-I2 of 2 models qualify · AHRI 213386537
Non-ducted, 2.5–3 tonsNo models in this size class73.4(50 is the typical model of its size class)CDHAM-36-O2 of 2 models qualify · AHRI 213386544

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAPLUSAll-around score, best modelCONTINENTALAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Ducted, 2 tonsNone on this board (0 of 2 models have all five ratings)60.8(50 is the typical model of its size class)CS18HV24A36with ducted air handler CPFX24AAlso listed as WSEHV2436RA1-C2 of 2 models have all five ratings · AHRI 207335556
Ducted, 2.5–3 tonsNone on this board (0 of 2 models have all five ratings)73.8(50 is the typical model of its size class)CDHAM-28-O1 of 1 models have all five ratings · AHRI 213386542
Ducted, 3.5–4.5 tonsNo models in this size class63.3(50 is the typical model of its size class)CS18HV48A60with ducted air handler CPFX48AAlso listed as WSEHV4860RA1-C2 of 2 models have all five ratings · AHRI 207335558
Non-ducted, up to 1.5 tonsNo models in this size class78.7(50 is the typical model of its size class)CDHAS22-18-Owith ductless indoor unit CDHAS22-18-I4 of 4 models have all five ratings · AHRI 213386540
Non-ducted, 2 tonsNo models in this size class84.3(50 is the typical model of its size class)CDHAS26-24-Owith ductless indoor unit CDHAS26-24-I2 of 2 models have all five ratings · AHRI 213386537
Non-ducted, 2.5–3 tonsNo models in this size class70.8(50 is the typical model of its size class)CDHAM-36-O2 of 2 models have all five ratings · AHRI 213386544

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAPLUSCONTINENTAL
COP at 5°F—beats 96% · 2.22CDHAS22-24-ONon-ducted, 2 tons
Capacity retention at 5°F—beats 89% · 99%CDHAM-36-ONon-ducted, 2.5–3 tons
HSPF2beats 21% · 7.5ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tonsbeats 93% · 11.4CDHAS26-24-ONon-ducted, 2 tons
SEER2beats 13% · 14.3ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tonsbeats 92% · 20.0CDHAM-28-ODucted, 2.5–3 tons
EER2beats 57% · 11.5ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tonsbeats 85% · 14.0CDHAS26-12-ONon-ducted, up to 1.5 tons
Heating capacity at 5°F—beats 94% · 36,600 Btu/hCDHAM-36-ONon-ducted, 2.5–3 tons

More comparisons