Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Breeze33 vs Innovair heat pumps
Measured against models of the same size and duct type, Breeze33 scores higher on 4 of the 6 ratings. Breeze33 has 45 outdoor models, Innovair has 44 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Breeze33
- Innovair
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Breeze33 | Innovair |
|---|---|---|
| Efficiency index | 62% (higher)median — · 5th ranked | 56% (higher)median — · 12th ranked |
| COP at 5°F | 53% (higher)median 2.00 · 15th ranked | 51% (higher)median 1.91 · 17th ranked |
| Capacity retention at 5°F | 60%median 79% · 9th ranked | 64%median 82% · 6th ranked |
| HSPF2 | 68% (higher)median 9.5 · 5th ranked | 53% (higher)median 8.8 · 13th ranked |
| SEER2 | 60% (higher)median 17.6 · 8th ranked | 50% (higher)median 17.0 · 12th ranked |
| EER2 | 59% (higher)median 12.0 · 5th ranked | 42% (higher)median 10.6 · 25th ranked |
| Heating capacity at 5°F | 56%median 19,300 Btu/h · 10th ranked | 64%median 21,555 Btu/h · 4th ranked |
| Outdoor models | 45 | 44 |
| AHRI certifications | 1,861 | 91 |
Share of models meeting each standard
| Standard | Breeze33 | Innovair |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7%30 models | 52.3%23 models |
| CEE 2026 Tier 1 (Split ASHP) | 64.4%29 models | 47.7%21 models |
| CEE Advanced Tier (Split ASHP) | 4.4%2 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 44.4%20 models | 47.7%21 models |
| DOE Cold Climate Heat Pump Challenge | 4.4%2 models | 0%0 models |
| ENERGY STAR Cold Climate | 46.7%21 models | 52.3%23 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Breeze33
- Innovair
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Breeze33 | Innovair |
|---|---|---|
| Ducted, up to 1.5 tons | 10 · index 65% | 5 · index 53% |
| Ducted, 2 tons | 4 · index 64% | 5 · index 63% |
| Ducted, 2.5–3 tons | 11 · index 64% | 7 · index 51% |
| Ducted, 3.5–4.5 tons | 9 · index 58% | 6 · index 53% |
| Ducted, 5 tons and up | None | 1 · index 42% |
| Non-ducted, up to 1.5 tons | 12 · index 62% | 11 · index 68% |
| Non-ducted, 2 tons | 3 · index 56% | 5 · index 68% |
| Non-ducted, 2.5–3 tons | 11 · index 61% | 7 · index 44% |
| Non-ducted, 3.5–4.5 tons | 3 · index 58% | 1 · index 45% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Breeze33Cold-climate score, best model | InnovairCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)BZ33-INV18OUT2-Jwith ducted air handler BZ33-WMAHU18-J9 of 10 models qualify · AHRI 214389567 | 86.9(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class) (higher)HSZ24H424ZMOwith ducted air handler D24H424ZMI3 of 4 models qualify · AHRI 211277594 | 75.6(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class) (higher)BZ33-HYP36OUT2-G2-Pwith ducted air handler BZ33-DIDU36-P5 of 11 models qualify · AHRI 215338140 | 78.6(50 is the typical model of its size class)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class) (higher)BZ33-HYP48OUT2-G2-Pwith ducted air handler BZ33-DIDU48-P4 of 9 models qualify · AHRI 215338141 | 73.8(50 is the typical model of its size class)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class) (higher)BZ33-HYP06OUT2-G2-Pwith ductless indoor unit BZ33-HYP06WALL2-G2-P8 of 12 models qualify · AHRI 207862069 | 80.1(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models qualify · AHRI 206330207 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class) (higher)BZ33-HYP24OUT2-G2-Pwith ductless indoor unit BZ33-CASS24-G2-PAlso listed as HSZ24H424ZMO2 of 3 models qualify · AHRI 207862078 | 68.5(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class) (higher)BZ33-HYP364Z2-G2-P4 of 11 models qualify · AHRI 207862104 | 64.0(50 is the typical model of its size class)VOM36H7R4P71 of 7 models qualify · AHRI 207821954 |
| Non-ducted, 3.5–4.5 tons | 76.2(50 is the typical model of its size class) (higher)BZ33-HYP485Z2-G2-P2 of 3 models qualify · AHRI 207862107 | 41.9(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958 |
All-around best
| Size and duct type | Breeze33All-around score, best model | InnovairAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.2(50 is the typical model of its size class) (higher)BZ33-HYP09OUT2-G2-Pwith ducted air handler BZ33-DIDU9-PAlso listed as HSZ9H424ZMO10 of 10 models have all five ratings · AHRI 207862079 | 82.8(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 213255597 |
| Ducted, 2 tons | 80.1(50 is the typical model of its size class) (higher)HSZ24H424ZMOwith ducted air handler D24H424ZMI4 of 4 models have all five ratings · AHRI 211277594 | 71.6(50 is the typical model of its size class)VOM24H7R3P75 of 5 models have all five ratings · AHRI 207821950 |
| Ducted, 2.5–3 tons | 75.4(50 is the typical model of its size class)BZ33-HP273Z2-G2-P11 of 11 models have all five ratings · AHRI 207862090 | 78.6(50 is the typical model of its size class) (higher)VOM36H7R4P77 of 7 models have all five ratings · AHRI 207821953 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class) (higher)BZ33-HYP485Z2-G2-P8 of 8 models have all five ratings · AHRI 207862108 | 60.7(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 207821956 |
| Ducted, 5 tons and up | 67.6(50 is the typical model of its size class) (higher)4HP17L60P-**Awith indoor coil 7EC60CX-0*+TDR and furnace 80G2UH110CE201 of 1 models have all five ratings · AHRI 214709273 | 41.7(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 208106863 |
| Non-ducted, up to 1.5 tons | 92.0(50 is the typical model of its size class) (higher)BZ33-HYP06OUT2-G2-Pwith ductless indoor unit BZ33-HYP06WALL2-G2-P12 of 12 models have all five ratings · AHRI 207862069 | 88.7(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models have all five ratings · AHRI 206330207 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class) (higher)BZ33-HYP24OUT2-G2-Pwith ductless indoor unit BZ33-HYP24WALL2-G2-P3 of 3 models have all five ratings · AHRI 207862073 | 76.3(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models have all five ratings · AHRI 206330210 |
| Non-ducted, 2.5–3 tons | 82.8(50 is the typical model of its size class) (higher)BZ33-HYP364Z2-G2-P8 of 11 models have all five ratings · AHRI 207862104 | 69.5(50 is the typical model of its size class)VOM36H7R4P75 of 7 models have all five ratings · AHRI 207821954 |
| Non-ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class) (higher)BZ33-HYP485Z2-G2-P3 of 3 models have all five ratings · AHRI 207862107 | 44.5(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Breeze33 | Innovair |
|---|---|---|
| COP at 5°F | beats 92% · 2.624HP17L60P-**ADucted, 3.5–4.5 tons | beats 91% · 2.37VEA36H2V18Ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 97% · 97%BZ33-HYP48OUT2-G2-PDucted, 3.5–4.5 tons | beats 99% · 144%EIN10H2V32(O)Non-ducted, up to 1.5 tons |
| HSPF2 | beats 99% · 10.3BZ33-HYP48OUT2-G2-PDucted, 3.5–4.5 tons | beats 93% · 10.8SHV18H2R20Ducted, up to 1.5 tons |
| SEER2 | beats 99% · 24.6BZ33-HP273Z2-G2-PNon-ducted, 2.5–3 tons | beats 96% · 21.0VOM24H7R3P7Ducted, 2 tons |
| EER2 | beats 100% · 14.04HP17L36P-**ADucted, 2.5–3 tons | beats 99% · 16.6EIN10H2V32(O)Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 98% · 41,000 Btu/hBZ33-HYP36OUT2-G2-PNon-ducted, 2.5–3 tons | beats 96% · 20,000 Btu/hEIN18H2V32(O)Non-ducted, up to 1.5 tons |