Skip to content

Carrier vs Ephoca heat pumps

Measured against models of the same size and duct type, Carrier scores higher on 4 of the 6 ratings. Carrier has 701 outdoor models, Ephoca has 30 outdoor models. Ephoca has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Ephoca on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Carrier scores higher on 4 of the 6 ratings.
  • Carrier
  • Ephoca
  • Other ranked manufacturers
CarrierEphoca

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierEphoca
Efficiency index47% (higher)median — · 23rd ranked20% (higher)median —
COP at 5°F58% (higher)median 2.00 · 8th ranked4% (higher)median 1.72
Capacity retention at 5°F32%median 53% · 27th ranked48%median 73%
HSPF238%median 7.7 · 21st ranked38%median 9.2
SEER245% (higher)median 15.5 · 20th ranked7% (higher)median 13.9
EER259% (higher)median 11.5 · 6th ranked14% (higher)median 10.6
Heating capacity at 5°F35% (higher)median 18,300 Btu/h · 27th ranked5% (higher)median 6,200 Btu/h
Outdoor models70130
AHRI certifications367,10130

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierEphoca
CEE 2025 Tier 1 (Split ASHP)28.5%200 models0%0 models
CEE 2026 Tier 1 (Split ASHP)25.5%179 models0%0 models
CEE Advanced Tier (Split ASHP)2%14 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)17.1%120 models0%0 models
DOE Cold Climate Heat Pump Challenge2%14 models0%0 models
ENERGY STAR Cold Climate8.8%62 models13.3%4 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • Carrier
  • Ephoca
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierEphoca
Ducted, up to 1.5 tons34 · index 48%26 · index 20%
Ducted, 2 tons100 · index 47%None
Ducted, 2.5–3 tons195 · index 47%None
Ducted, 3.5–4.5 tons256 · index 43%None
Ducted, 5 tons and up67 · index 60%None
Non-ducted, up to 1.5 tons42 · index 55%4 · index 25%
Non-ducted, 2 tons9 · index 53%None
Non-ducted, 2.5–3 tons31 · index 52%None
Non-ducted, 3.5–4.5 tons17 · index 48%None
Non-ducted, 5 tons and up1 · index 86%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelEphocaCold-climate score, best model
Ducted, up to 1.5 tons81.3(50 is the typical model of its size class) (higher)38MARBQ18AA3with ducted air handler 40MBDAQ18XH3Also sold as Arcoaire DLCSRBH18AAK21 of 33 models qualify · AHRI 21113291841.4(50 is the typical model of its size class)AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 more26 of 26 models qualify · AHRI 213607332
Ducted, 2 tons95.9(50 is the typical model of its size class)38MURAQ24AB3*with indoor coil H,PG7J936 and furnace 927TA48060V1735 of 99 models qualify · AHRI 216761973No models in this size class
Ducted, 2.5–3 tons96.4(50 is the typical model of its size class)38MURAQ36AB3*with indoor coil H,PG48936 and furnace 927TA60080V2143 of 197 models qualify · AHRI 216761988No models in this size class
Ducted, 3.5–4.5 tons87.7(50 is the typical model of its size class)MCY-MAP0487HS-UL*26 of 256 models qualify · AHRI 213350254No models in this size class
Ducted, 5 tons and up91.5(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 67 models qualify · AHRI 213350251No models in this size class
Non-ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA324 of 42 models qualify · AHRI 20782664432.8(50 is the typical model of its size class)APP10*4*1with ductless indoor unit APP10*4*1Also listed as APP10*4*2, APK10*4*24 of 4 models qualify · AHRI 213607324
Non-ducted, 2 tons86.1(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as Arcoaire DLCSRBH24AAK5 of 9 models qualify · AHRI 207683292No models in this size class
Non-ducted, 2.5–3 tons85.9(50 is the typical model of its size class)MCY-MAP0367HS-UL*7 of 31 models qualify · AHRI 213350255No models in this size class
Non-ducted, 3.5–4.5 tons82.0(50 is the typical model of its size class)MCY-MAP0487HS-UL*11 of 17 models qualify · AHRI 213350250No models in this size class
Non-ducted, 5 tons and up89.2(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models qualify · AHRI 213350252No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelEphocaAll-around score, best model
Ducted, up to 1.5 tons85.2(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as Arcoaire DLCSRBH09AAK32 of 33 models have all five ratings · AHRI 20635032828.9(50 is the typical model of its size class)AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 more26 of 26 models have all five ratings · AHRI 213607332
Ducted, 2 tons88.8(50 is the typical model of its size class)25VNA424A*031*with indoor coil CAP**3721AL*+UI and furnace 58TN*A090C17**16Also sold as Bryant Heating and Cooling Systems 284ANV024*0**B90 of 92 models have all five ratings · AHRI 210533008No models in this size class
Ducted, 2.5–3 tons91.0(50 is the typical model of its size class)MCY-MAP0367HS-UL162 of 203 models have all five ratings · AHRI 10049878No models in this size class
Ducted, 3.5–4.5 tons92.1(50 is the typical model of its size class)25VNA448A*031*with ducted air handler FE4BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 284ANV048*0**B201 of 253 models have all five ratings · AHRI 213361591No models in this size class
Ducted, 5 tons and up91.6(50 is the typical model of its size class)25VNA460A*031*with ducted air handler FE4BNBD60L*+UI40 of 71 models have all five ratings · AHRI 213361593No models in this size class
Non-ducted, up to 1.5 tons93.6(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA342 of 42 models have all five ratings · AHRI 20782664425.1(50 is the typical model of its size class)APP10*4*1with ductless indoor unit APP10*4*1Also listed as APP10*4*2, APK10*4*24 of 4 models have all five ratings · AHRI 213607324
Non-ducted, 2 tons84.3(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit 40MAHBQ24XA3Also sold as Arcoaire DLCSRBH24AAK9 of 9 models have all five ratings · AHRI 206348138No models in this size class
Non-ducted, 2.5–3 tons90.0(50 is the typical model of its size class)RAV-SP302AT2P-ULwith ductless indoor unit RAV-SM302UTP-UL27 of 31 models have all five ratings · AHRI 208447324No models in this size class
Non-ducted, 3.5–4.5 tons87.5(50 is the typical model of its size class)MCY-MAP0487HS-UL*17 of 17 models have all five ratings · AHRI 213350250No models in this size class
Non-ducted, 5 tons and up85.8(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models have all five ratings · AHRI 213350252No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierEphoca
COP at 5°Fbeats 100% · 2.70MCY-MAP0367HS-UL*Non-ducted, 2.5–3 tonsbeats 6% · 1.75APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 160%WDLCURAH18ABKDucted, up to 1.5 tonsbeats 68% · 81%APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tons
HSPF2beats 100% · 15.038MPRBQ09AA3Also sold as Arcoaire DLCPRBH09AAKNon-ducted, up to 1.5 tonsbeats 73% · 9.9AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 moreDucted, up to 1.5 tons
SEER2beats 100% · 23.1MCY-MAP0607HS-UL*Non-ducted, 5 tons and upbeats 9% · 14.4AVP10*4*1Also listed as AVP10*4*2, AVE10*4*2, AVK10*4*2, AXP10*4*1 and 4 moreDucted, up to 1.5 tons
EER2beats 100% · 13.5T4H5S42*K*AAA*Ducted, 3.5–4.5 tonsbeats 34% · 11.2APP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 96,220 Btu/h38MURAQ60AB3*Also sold as Grandaire WDLCURAH60ABKDucted, 3.5–4.5 tonsbeats 11% · 6,700 Btu/hAPP10*4*1Also listed as APP10*4*2, APK10*4*2Non-ducted, up to 1.5 tons

More comparisons