Skip to content

Clima Smart vs Convectair heat pumps

Measured against models of the same size and duct type, Convectair scores higher on 4 of the 6 ratings. Clima Smart has 4 outdoor models, Convectair has 16 outdoor models. Clima Smart and Convectair have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Clima Smart and Convectair on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Convectair scores higher on 4 of the 6 ratings.
  • Clima Smart
  • Convectair
  • Other ranked manufacturers
Clima Sm…Convecta…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingClima SmartConvectair
Efficiency index61%median —62%median —
COP at 5°F81% (higher)median 2.1943% (higher)median 1.87
Capacity retention at 5°F50%median 72%70%median 89%
HSPF247%median 9.069%median 10.2
SEER262%median 22.063%median 21.7
EER264% (higher)median 12.862% (higher)median 12.5
Heating capacity at 5°F51%median 10,885 Btu/h68%median 15,750 Btu/h
Outdoor models416
AHRI certifications424

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardClima SmartConvectair
CEE 2025 Tier 1 (Split ASHP)100%4 models75%12 models
CEE 2026 Tier 1 (Split ASHP)100%4 models75%12 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)75%3 models75%12 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • Clima Smart
  • Convectair
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeClima SmartConvectair
Ducted, up to 1.5 tonsNone1 · index 59%
Ducted, 2.5–3 tonsNone2 · index 73%
Ducted, 3.5–4.5 tonsNone1 · index 82%
Non-ducted, up to 1.5 tons3 · index 64%10 · index 55%
Non-ducted, 2 tons1 · index 53%3 · index 52%
Non-ducted, 2.5–3 tonsNone2 · index 78%
Non-ducted, 3.5–4.5 tonsNone1 · index 78%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeClima SmartCold-climate score, best modelConvectairCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class50.4(50 is the typical model of its size class)8222-C18-O1 of 1 models qualify · AHRI 207590847
Ducted, 2.5–3 tonsNo models in this size class66.7(50 is the typical model of its size class)8322-C27-O2 of 2 models qualify · AHRI 207590850
Ducted, 3.5–4.5 tonsNo models in this size class74.9(50 is the typical model of its size class)8522-C48-O1 of 1 models qualify · AHRI 207590853
Non-ducted, up to 1.5 tons68.8(50 is the typical model of its size class)MCH12-CS-S23-230V-Owith ductless indoor unit MCH12-CS-S23-230V-I3 of 3 models qualify · AHRI 21314899676.2(50 is the typical model of its size class) (higher)8028-C09-Owith ductless indoor unit 8028-C09-I8 of 10 models qualify · AHRI 207709204
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)84.5(50 is the typical model of its size class)8028-C24-Owith ductless indoor unit 8028-C24-I2 of 3 models qualify · AHRI 207709207
Non-ducted, 2.5–3 tonsNo models in this size class79.3(50 is the typical model of its size class)8422-C36-O2 of 2 models qualify · AHRI 207657622
Non-ducted, 3.5–4.5 tonsNo models in this size class76.2(50 is the typical model of its size class)8522-C48-O1 of 1 models qualify · AHRI 207590852

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeClima SmartAll-around score, best modelConvectairAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class58.6(50 is the typical model of its size class)8222-C18-O1 of 1 models have all five ratings · AHRI 207590847
Ducted, 2.5–3 tonsNo models in this size class74.6(50 is the typical model of its size class)8322-C27-O2 of 2 models have all five ratings · AHRI 207590850
Ducted, 3.5–4.5 tonsNo models in this size class82.0(50 is the typical model of its size class)8522-C48-O1 of 1 models have all five ratings · AHRI 207590853
Non-ducted, up to 1.5 tons70.8(50 is the typical model of its size class)MCH12-CS-S23-230V-Owith ductless indoor unit MCH12-CS-S23-230V-I3 of 3 models have all five ratings · AHRI 21314899687.0(50 is the typical model of its size class) (higher)8028-C09-Owith ductless indoor unit 8028-C09-I10 of 10 models have all five ratings · AHRI 207709204
Non-ducted, 2 tons53.0(50 is the typical model of its size class)MCH24-CS-S23-Owith ductless indoor unit MCH24-CS-S23-I1 of 1 models have all five ratings · AHRI 21125710684.3(50 is the typical model of its size class) (higher)8028-C24-Owith ductless indoor unit 8028-C24-I3 of 3 models have all five ratings · AHRI 207709207
Non-ducted, 2.5–3 tonsNo models in this size class82.8(50 is the typical model of its size class)8422-C36-O2 of 2 models have all five ratings · AHRI 207657622
Non-ducted, 3.5–4.5 tonsNo models in this size class77.9(50 is the typical model of its size class)8522-C48-O1 of 1 models have all five ratings · AHRI 207590852

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingClima SmartConvectair
COP at 5°Fbeats 89% · 2.21MCH18-CS-S23-ONon-ducted, up to 1.5 tonsbeats 91% · 2.218028-C24-ONon-ducted, 2 tons
Capacity retention at 5°Fbeats 61% · 76%MCH12-CS-S23-230V-ONon-ducted, up to 1.5 tonsbeats 85% · 100%8222-C18-ODucted, up to 1.5 tons
HSPF2beats 57% · 9.5MCH12-CS-S23-230V-ONon-ducted, up to 1.5 tonsbeats 95% · 10.68322-C27-ONon-ducted, 2.5–3 tons
SEER2beats 73% · 23.0MCH12-CS-S23-230V-ONon-ducted, up to 1.5 tonsbeats 99% · 20.98522-C48-ODucted, 3.5–4.5 tons
EER2beats 68% · 13.0MCH18-CS-S23-ONon-ducted, up to 1.5 tonsbeats 98% · 16.28028-C09-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 73% · 12,600 Btu/hMCH18-CS-S23-ONon-ducted, up to 1.5 tonsbeats 96% · 20,000 Btu/h8222-C18-ONon-ducted, up to 1.5 tons

More comparisons