Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Cooper&Hunter vs ECO-AIR heat pumps
Measured against models of the same size and duct type, ECO-AIR scores higher on 4 of the 6 ratings. Cooper&Hunter has 57 outdoor models, ECO-AIR has 58 outdoor models. ECO-AIR has no QMID on file and is not ranked. They share hardware: 53 equipment families appear under both names.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Cooper&Hunter
- ECO-AIR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Cooper&Hunter | ECO-AIR |
|---|---|---|
| Efficiency index | 57% (higher)median — · 11th ranked | 56% (higher)median — |
| COP at 5°F | 55% (higher)median 2.00 · 13th ranked | 51% (higher)median 1.98 |
| Capacity retention at 5°F | 56% (higher)median 70% · 12th ranked | 53% (higher)median 68% |
| HSPF2 | 64%median 9.4 · 8th ranked | 69%median 9.4 |
| SEER2 | 56%median 19.8 · 10th ranked | 62%median 19.3 |
| EER2 | 45%median 10.5 · 22nd ranked | 47%median 10.9 |
| Heating capacity at 5°F | 53%median 17,500 Btu/h · 15th ranked | 56%median 20,000 Btu/h |
| Outdoor models | 57 | 58 |
| AHRI certifications | 408 | 142 |
Share of models meeting each standard
| Standard | Cooper&Hunter | ECO-AIR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.9%33 models | 62.1%36 models |
| CEE 2026 Tier 1 (Split ASHP) | 56.1%32 models | 58.6%34 models |
| CEE Advanced Tier (Split ASHP) | 1.8%1 models | 1.7%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.6%26 models | 44.8%26 models |
| DOE Cold Climate Heat Pump Challenge | 1.8%1 models | 1.7%1 models |
| ENERGY STAR Cold Climate | 42.1%24 models | 50%29 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Cooper&Hunter
- ECO-AIR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Cooper&Hunter | ECO-AIR |
|---|---|---|
| Ducted, up to 1.5 tons | 8 · index 67% | 12 · index 61% |
| Ducted, 2 tons | 2 · index 82% | 4 · index 70% |
| Ducted, 2.5–3 tons | 10 · index 56% | 15 · index 53% |
| Ducted, 3.5–4.5 tons | 10 · index 58% | 10 · index 56% |
| Ducted, 5 tons and up | 3 · index 55% | 2 · index 49% |
| Non-ducted, up to 1.5 tons | 24 · index 56% | 18 · index 55% |
| Non-ducted, 2 tons | 5 · index 47% | 5 · index 53% |
| Non-ducted, 2.5–3 tons | 13 · index 59% | 10 · index 58% |
| Non-ducted, 3.5–4.5 tons | 11 · index 49% | 6 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | Cooper&HunterCold-climate score, best model | ECO-AIRCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI7 of 8 models qualify · AHRI 207742328 | 86.9(50 is the typical model of its size class) (higher)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E9 of 12 models qualify · AHRI 213307908 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models qualify · AHRI 207742325 | 80.3(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models qualify · AHRI 211644052 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)CH-HYP36LCUOwith ducted air handler CH-36LCDTU/IAlso listed as CH-NHPR36LCU-230VO4 of 10 models qualify · AHRI 205901586 | 79.9(50 is the typical model of its size class)MOE30U-36HFN1-M(GA)with ducted air handler MTI-36HWFN1-M7 of 15 models qualify · AHRI 211644066 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)CH-HYP48LCUOwith ducted air handler CH-48LCDTU/IAlso listed as CH-NHPR48LCU-230VO5 of 10 models qualify · AHRI 205263864 | 86.4(50 is the typical model of its size class)MOE30U-48HFN1-M-[X](GA)with ducted air handler MTI-48HWFN1-M7 of 11 models qualify · AHRI 211644067 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI14 of 24 models qualify · AHRI 207740500 | 89.3(50 is the typical model of its size class)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W9 of 18 models qualify · AHRI 208121863 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-N24MSPHCT-230VI3 of 5 models qualify · AHRI 207742335 | 86.1(50 is the typical model of its size class)MOD30-24HFN1-MU0Wwith ductless indoor unit MCD1-24HRFN1-MT0W(GA)2 of 5 models qualify · AHRI 211644071 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)CH-HPR36M-230VO4 of 13 models qualify · AHRI 207742379 | 87.0(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X4 of 10 models qualify · AHRI 213307915 |
| Non-ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class) (higher)CH-NHPR60LCU-230VOwith ductless indoor unit CH-60LCFC/I5 of 11 models qualify · AHRI 211246027 | 76.2(50 is the typical model of its size class)M5OG-48HFN1-M-[X]3 of 6 models qualify · AHRI 209319647 |
All-around best
| Size and duct type | Cooper&HunterAll-around score, best model | ECO-AIRAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.2(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI8 of 8 models have all five ratings · AHRI 207742328 | 85.2(50 is the typical model of its size class)MOX330-09HFN1-MY5Wwith ducted air handler MTIU-09HWFN1-M12 of 12 models have all five ratings · AHRI 211644062 |
| Ducted, 2 tons | 83.8(50 is the typical model of its size class)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models have all five ratings · AHRI 207742325 | 83.8(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models have all five ratings · AHRI 211644052 |
| Ducted, 2.5–3 tons | 75.4(50 is the typical model of its size class)CH-28MES-230VO8 of 10 models have all five ratings · AHRI 207742365 | 83.7(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X15 of 15 models have all five ratings · AHRI 213307916 |
| Ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class)CH-HPR48M-230VO8 of 10 models have all five ratings · AHRI 207742382 | 82.0(50 is the typical model of its size class)M5OG-48HFN1-M-[X]11 of 11 models have all five ratings · AHRI 209319648 |
| Ducted, 5 tons and up | 57.1(50 is the typical model of its size class)CH-N60LCU-230VOwith ducted air handler CH-60LCDTU/I3 of 3 models have all five ratings · AHRI 207742344 | 57.1(50 is the typical model of its size class)MOE30U-60HFN1-M(GA)(X)with ducted air handler MHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 211644055 |
| Non-ducted, up to 1.5 tons | 92.0(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI24 of 24 models have all five ratings · AHRI 207740500 | 92.0(50 is the typical model of its size class)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W18 of 18 models have all five ratings · AHRI 208121863 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-24MASTWM-230VI5 of 5 models have all five ratings · AHRI 207740504 | 84.3(50 is the typical model of its size class)MOD30-24HFN1-MU0Wwith ductless indoor unit MSEPD-24HRFN1-MU0W5 of 5 models have all five ratings · AHRI 208121867 |
| Non-ducted, 2.5–3 tons | 82.8(50 is the typical model of its size class)CH-HPR36M-230VO9 of 13 models have all five ratings · AHRI 207742379 | 82.8(50 is the typical model of its size class)M4OI-36HFN1-M10 of 10 models have all five ratings · AHRI 209319644 |
| Non-ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class)CH-HPR48M-230VO8 of 11 models have all five ratings · AHRI 207742381 | 77.9(50 is the typical model of its size class)M5OG-48HFN1-M-[X]6 of 6 models have all five ratings · AHRI 209319647 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Cooper&Hunter | ECO-AIR |
|---|---|---|
| COP at 5°F | beats 98% · 2.45CH-ES12-230VONon-ducted, up to 1.5 tons | beats 98% · 2.45MOX230-12HFN1-MV5WNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 97%CH-NHPR48LCU-230VODucted, 3.5–4.5 tons | beats 97% · 111%MOX430U-18HFN1-MDucted, up to 1.5 tons |
| HSPF2 | beats 99% · 10.3CH-HYP48LCUOAlso listed as CH-NHPR48LCU-230VODucted, 3.5–4.5 tons | beats 99% · 10.3MOE30U-48HFN1-M-[X](GA)Ducted, 3.5–4.5 tons |
| SEER2 | beats 99% · 24.6CH-28MES-230VONon-ducted, 2.5–3 tons | beats 99% · 24.6M3OJ-27HFN1-MNon-ducted, 2.5–3 tons |
| EER2 | beats 98% · 16.2CH-HPR09-230VONon-ducted, up to 1.5 tons | beats 98% · 16.2MOX330-09HFN1-MY5WNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 57,600 Btu/hCH-NHPR60LCU-230VODucted, 3.5–4.5 tons | beats 98% · 41,000 Btu/hMOE30U-36HFN1-M(GA)Non-ducted, 2.5–3 tons |