Skip to content

First Co. vs TK'S heat pumps

Measured against models of the same size and duct type, TK'S scores higher on 6 of the 6 ratings. First Co. has 16 outdoor models, TK'S has 15 outdoor models. First Co. and TK'S have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
First Co. and TK'S on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, TK'S scores higher on 6 of the 6 ratings.
  • First Co.
  • TK'S
  • Other ranked manufacturers
First Co.TK'S

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFirst Co.TK'S
Efficiency index7%median —48%median —
COP at 5°F16%median 1.6034%median 1.83
Capacity retention at 5°F9%median 46%31%median 65%
HSPF22%median 6.358%median 9.1
SEER21%median 11.964%median 21.1
EER210%median 10.047%median 10.8
Heating capacity at 5°F9%median 8,000 Btu/h38%median 12,600 Btu/h
Outdoor models1615
AHRI certifications3429

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFirst Co.TK'S
CEE 2025 Tier 1 (Split ASHP)0%0 models66.7%10 models
CEE 2026 Tier 1 (Split ASHP)0%0 models46.7%7 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models20%3 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 1 groups where both have models
  • First Co.
  • TK'S
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFirst Co.TK'S
Ducted, up to 1.5 tons8 · index 6%2 · index 59%
Ducted, 2 tons8 · index 8%None
Ducted, 2.5–3 tonsNone3 · index 62%
Ducted, 3.5–4.5 tonsNone2 · index 64%
Non-ducted, up to 1.5 tonsNone8 · index 40%
Non-ducted, 2 tonsNone1 · index 16%
Non-ducted, 2.5–3 tonsNone4 · index 50%
Non-ducted, 3.5–4.5 tonsNone2 · index 48%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFirst Co.Cold-climate score, best modelTK'SCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 8 models qualify)52.0(50 is the typical model of its size class)T2C-18HFN1Also listed as T2C-18HFN12 of 2 models qualify · AHRI 207742406
Ducted, 2 tonsNone on this board (0 of 8 models qualify)No models in this size class
Ducted, 2.5–3 tonsNo models in this size class57.4(50 is the typical model of its size class)T3C-30HFN1*1 of 3 models qualify · AHRI 212528010
Ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 8 models qualify)
Non-ducted, 2 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, 2.5–3 tonsNo models in this size class49.3(50 is the typical model of its size class)T3C-30HFN1*1 of 4 models qualify · AHRI 212528009
Non-ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFirst Co.All-around score, best modelTK'SAll-around score, best model
Ducted, up to 1.5 tons11.5(50 is the typical model of its size class)EHE18***B7 of 8 models have all five ratings · AHRI 21336956159.4(50 is the typical model of its size class) (higher)T2C-18HFN1Also listed as T2C-18HFN12 of 2 models have all five ratings · AHRI 207742406
Ducted, 2 tons18.0(50 is the typical model of its size class)EHE24***B6 of 8 models have all five ratings · AHRI 213369562No models in this size class
Ducted, 2.5–3 tonsNo models in this size class71.5(50 is the typical model of its size class)T3C-30HFN1*3 of 3 models have all five ratings · AHRI 212528010
Ducted, 3.5–4.5 tonsNo models in this size class63.5(50 is the typical model of its size class)T5C-48HFN1Also listed as T5C-48HFN12 of 2 models have all five ratings · AHRI 207742412
Non-ducted, up to 1.5 tonsNo models in this size class52.0(50 is the typical model of its size class)T2C-18HFN1Also listed as T2C-18HFN18 of 8 models have all five ratings · AHRI 207742405
Non-ducted, 2 tonsNo models in this size class15.9(50 is the typical model of its size class)TWS-24HRDN1with ductless indoor unit TWS-24HRDN11 of 1 models have all five ratings · AHRI 205807089
Non-ducted, 2.5–3 tonsNo models in this size class66.7(50 is the typical model of its size class)T3C-30HFN1*4 of 4 models have all five ratings · AHRI 212528009
Non-ducted, 3.5–4.5 tonsNo models in this size class48.3(50 is the typical model of its size class)T5C-48HFN1Also listed as T5C-48HFN12 of 2 models have all five ratings · AHRI 207742411

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFirst Co.TK'S
COP at 5°Fbeats 64% · 2.08EHE30***BDucted, 2 tonsbeats 86% · 2.18TWS-18HRDN1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 20% · 55%EHE30***BDucted, 2 tonsbeats 55% · 71%T3C-30HFN1*Ducted, 2.5–3 tons
HSPF2beats 14% · 7.224WHHPDucted, 2 tonsbeats 95% · 9.7T5C-48HFN1Also listed as T5C-48HFN1Ducted, 3.5–4.5 tons
SEER2beats 11% · 13.519WHHPDucted, 2 tonsbeats 98% · 21.0T3C-30HFN1*Ducted, 2.5–3 tons
EER2beats 78% · 12.419WHHPDucted, 2 tonsbeats 75% · 12.2T3C-30HFN1*Non-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 30% · 14,000 Btu/hEHE30***BDucted, 2 tonsbeats 75% · 12,900 Btu/hT2C-18HFN1Also listed as T2C-18HFN1Non-ducted, up to 1.5 tons

More comparisons