Skip to content

Fujitsu vs TCL heat pumps

Measured against models of the same size and duct type, Fujitsu scores higher on 6 of the 6 ratings. Fujitsu has 164 outdoor models, TCL has 52 outdoor models. TCL has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Fujitsu and TCL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Fujitsu scores higher on 6 of the 6 ratings.
  • Fujitsu
  • TCL
  • Other ranked manufacturers
FujitsuTCL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFujitsuTCL
Efficiency index58% (higher)median — · 9th ranked43% (higher)median —
COP at 5°F70% (higher)median 2.10 · 2nd ranked48% (higher)median 1.90
Capacity retention at 5°F65% (higher)median 81% · 3rd ranked43% (higher)median 70%
HSPF253% (higher)median 8.5 · 12th ranked31% (higher)median 8.5
SEER246% (higher)median 16.6 · 19th ranked38% (higher)median 19.0
EER249% (higher)median 11.5 · 17th ranked30% (higher)median 10.0
Heating capacity at 5°F62% (higher)median 20,800 Btu/h · 5th ranked50% (higher)median 16,720 Btu/h
Outdoor models16452
AHRI certifications765229

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFujitsuTCL
CEE 2025 Tier 1 (Split ASHP)38.4%63 models42.3%22 models
CEE 2026 Tier 1 (Split ASHP)37.8%62 models38.5%20 models
CEE Advanced Tier (Split ASHP)6.1%10 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)34.1%56 models36.5%19 models
DOE Cold Climate Heat Pump Challenge6.1%10 models0%0 models
ENERGY STAR Cold Climate28%46 models23.1%12 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • Fujitsu
  • TCL
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFujitsuTCL
Ducted, up to 1.5 tons15 · index 39%1 · index 31%
Ducted, 2 tons14 · index 53%5 · index 53%
Ducted, 2.5–3 tons36 · index 54%4 · index 49%
Ducted, 3.5–4.5 tons42 · index 51%3 · index 55%
Ducted, 5 tons and up12 · index 64%None
Non-ducted, up to 1.5 tons44 · index 74%23 · index 38%
Non-ducted, 2 tons9 · index 65%8 · index 47%
Non-ducted, 2.5–3 tons14 · index 59%8 · index 35%
Non-ducted, 3.5–4.5 tons5 · index 46%None
Non-ducted, 5 tons and up1 · index 18%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFujitsuCold-climate score, best modelTCLCold-climate score, best model
Ducted, up to 1.5 tons83.5(50 is the typical model of its size class) (higher)AOUH12LUAS1with ducted air handler ARUH12LUAS5 of 15 models qualify · AHRI 20733430156.1(50 is the typical model of its size class)THH18HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 1 models qualify · AHRI 212400611
Ducted, 2 tons75.4(50 is the typical model of its size class) (higher)AOU24RLXFZH6 of 14 models qualify · AHRI 803374255.3(50 is the typical model of its size class)THH24HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 2 models qualify · AHRI 212390892
Ducted, 2.5–3 tons86.6(50 is the typical model of its size class) (higher)AOUH30LUAS1with ducted air handler ARUH30LUAS12 of 36 models qualify · AHRI 21107883766.7(50 is the typical model of its size class)TCU-36D7HEWA/DV2Owith ducted air handler TCU-36D7HWA/DV2I6 of 6 models qualify · AHRI 207827230
Ducted, 3.5–4.5 tons83.5(50 is the typical model of its size class) (higher)AOU42RGLXwith ducted air handler ARU42RGLX7 of 42 models qualify · AHRI 20253755062.3(50 is the typical model of its size class)TCE-60HA/DV2Owith ducted air handler TCE-60D7HWA/DV2I4 of 4 models qualify · AHRI 201864499
Ducted, 5 tons and upNone on this board (0 of 12 models qualify)No models in this size class
Non-ducted, up to 1.5 tons96.9(50 is the typical model of its size class) (higher)AOUG12LZAS1with ductless indoor unit ASUG12LZAS28 of 44 models qualify · AHRI 20474006868.8(50 is the typical model of its size class)TSC-12HA2/I3TI23with ductless indoor unit TSC-12HA2/I3TI23-I10 of 23 models qualify · AHRI 207688890
Non-ducted, 2 tons89.0(50 is the typical model of its size class)AOUH24LMAS1with ductless indoor unit ASUH24LMAS6 of 9 models qualify · AHRI 206913028None on this board (0 of 8 models qualify)
Non-ducted, 2.5–3 tons90.6(50 is the typical model of its size class)AOU30RLXEHwith ductless indoor unit ASU30RLE11 of 14 models qualify · AHRI 8912454None on this board (0 of 8 models qualify)
Non-ducted, 3.5–4.5 tons75.3(50 is the typical model of its size class)AOU42RGLXwith ductless indoor unit AUU42RGLX2 of 5 models qualify · AHRI 202195867No models in this size class
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFujitsuAll-around score, best modelTCLAll-around score, best model
Ducted, up to 1.5 tons82.7(50 is the typical model of its size class) (higher)AOUH12LUAS1with ducted air handler ARUH12LUAS9 of 15 models have all five ratings · AHRI 20733430130.7(50 is the typical model of its size class)THH18HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 1 models have all five ratings · AHRI 212400611
Ducted, 2 tons80.6(50 is the typical model of its size class) (higher)FOP1824MJAZCAwith indoor coil FCCA2421HZEA and furnace FF97MV306017DHS*A11 of 14 models have all five ratings · AHRI 20988002476.7(50 is the typical model of its size class)TCU-36D7HEWA/DV2Owith ducted air handler TCU-24D7HWA/DV2I4 of 4 models have all five ratings · AHRI 207827229
Ducted, 2.5–3 tons87.2(50 is the typical model of its size class) (higher)FOP1836MJAZCAwith indoor coil FCCA6021SZEA and furnace FF75173LT80X22 of 36 models have all five ratings · AHRI 21086891167.3(50 is the typical model of its size class)TCE-60HA/DV2Owith ducted air handler TCU-36D7HWA/DV2I6 of 6 models have all five ratings · AHRI 211869249
Ducted, 3.5–4.5 tons81.5(50 is the typical model of its size class) (higher)FOP1848MJAZCA1with ducted air handler FHRAVM6021SJZECA23 of 42 models have all five ratings · AHRI 20858741374.0(50 is the typical model of its size class)TCU-60D7HEWA/DV2Owith ducted air handler TCU-48D7HWA/DV2I2 of 2 models have all five ratings · AHRI 207827118
Ducted, 5 tons and up70.2(50 is the typical model of its size class)FOP1560TJAZNAwith indoor coil FCCN6024SZTA and furnace FF97MV510021DHS*A3 of 12 models have all five ratings · AHRI 212507664No models in this size class
Non-ducted, up to 1.5 tons96.2(50 is the typical model of its size class) (higher)AOUG12LZAS1with ductless indoor unit ASUG12LZAS29 of 44 models have all five ratings · AHRI 20474006870.8(50 is the typical model of its size class)TSC-12HA2/I3TI23with ductless indoor unit TSC-12HA2/I3TI23-I14 of 23 models have all five ratings · AHRI 207688890
Non-ducted, 2 tons86.5(50 is the typical model of its size class) (higher)AOUH24LUAS1with ductless indoor unit AUUH24LUAS7 of 9 models have all five ratings · AHRI 21107883161.7(50 is the typical model of its size class)TUM-27HA2/I2I21-21ES3 of 8 models have all five ratings · AHRI 209424844
Non-ducted, 2.5–3 tons79.2(50 is the typical model of its size class) (higher)AOU36RLXFZH12 of 14 models have all five ratings · AHRI 890861565.0(50 is the typical model of its size class)TUM-36HA2/I2I21-21ES5 of 8 models have all five ratings · AHRI 209424845
Non-ducted, 3.5–4.5 tons65.1(50 is the typical model of its size class)AOU42RGLXwith ductless indoor unit AUU42RGLX5 of 5 models have all five ratings · AHRI 202195867No models in this size class
Non-ducted, 5 tons and up17.7(50 is the typical model of its size class)AOU60RLAVM41 of 1 models have all five ratings · AHRI 206347299No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFujitsuTCL
COP at 5°Fbeats 100% · 2.91AOU48RLAVS4Non-ducted, 3.5–4.5 tonsbeats 98% · 2.27TUM-27HA2/I2I21-21ESNon-ducted, 2 tons
Capacity retention at 5°Fbeats 100% · 158%AOU9RLFFNon-ducted, up to 1.5 tonsbeats 100% · 142%THH24HAI2NAF2U23Ducted, 2 tons
HSPF2beats 98% · 13.4AOUG09LZAS1Non-ducted, up to 1.5 tonsbeats 73% · 9.2TCU-60D7HEWA/DV2ODucted, 2.5–3 tons
SEER2beats 100% · 33.1AOUG09LZAS1Non-ducted, up to 1.5 tonsbeats 94% · 20.0TCU-36D7HEWA/DV2ODucted, 2 tons
EER2beats 100% · 18.0AOUG09LZAS1Non-ducted, up to 1.5 tonsbeats 95% · 13.0TCU-36D7HEWA/DV2ODucted, 2 tons
Heating capacity at 5°Fbeats 100% · 43,500 Btu/hFOP1836MJAZCADucted, 2.5–3 tonsbeats 100% · 34,000 Btu/hTHH18HAI2NAF2U23Ducted, up to 1.5 tons

More comparisons