Skip to content

HAIER vs JANITROL heat pumps

Measured against models of the same size and duct type, HAIER scores higher on 4 of the 6 ratings. HAIER has 48 outdoor models, JANITROL has 47 outdoor models. HAIER and JANITROL have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
HAIER and JANITROL on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HAIER scores higher on 4 of the 6 ratings.
  • HAIER
  • JANITROL
  • Other ranked manufacturers
HAIERJANITROL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHAIERJANITROL
Efficiency index43% (higher)median —39% (higher)median —
COP at 5°F29%median 1.8040%median 1.92
Capacity retention at 5°F46% (higher)median 71%13% (higher)median 46%
HSPF256% (higher)median 9.521% (higher)median 7.0
SEER246% (higher)median 20.030% (higher)median 15.2
EER239%median 12.067%median 11.4
Heating capacity at 5°F49% (higher)median 15,050 Btu/h13% (higher)median 15,200 Btu/h
Outdoor models4847
AHRI certifications993,377

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHAIERJANITROL
CEE 2025 Tier 1 (Split ASHP)54.2%26 models6.4%3 models
CEE 2026 Tier 1 (Split ASHP)54.2%26 models2.1%1 models
CEE Advanced Tier (Split ASHP)4.2%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)45.8%22 models0%0 models
DOE Cold Climate Heat Pump Challenge4.2%2 models0%0 models
ENERGY STAR Cold Climate33.3%16 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • HAIER
  • JANITROL
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHAIERJANITROL
Ducted, up to 1.5 tons6 · index 36%3 · index 39%
Ducted, 2 tons5 · index 42%8 · index 37%
Ducted, 2.5–3 tons6 · index 38%15 · index 39%
Ducted, 3.5–4.5 tons5 · index 34%19 · index 42%
Ducted, 5 tons and upNone2 · index 36%
Non-ducted, up to 1.5 tons25 · index 55%None
Non-ducted, 2 tons9 · index 46%None
Non-ducted, 2.5–3 tons6 · index 32%None
Non-ducted, 3.5–4.5 tons4 · index 15%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHAIERCold-climate score, best modelJANITROLCold-climate score, best model
Ducted, up to 1.5 tons52.9(50 is the typical model of its size class)2U20EH2HD**4 of 6 models qualify · AHRI 210151026None on this board (0 of 3 models qualify)
Ducted, 2 tons57.0(50 is the typical model of its size class)3U24EH2HD**2 of 5 models qualify · AHRI 210082199None on this board (0 of 8 models qualify)
Ducted, 2.5–3 tons62.0(50 is the typical model of its size class)4U36EH2HD**2 of 6 models qualify · AHRI 210151027None on this board (0 of 15 models qualify)
Ducted, 3.5–4.5 tons53.6(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD1 of 5 models qualify · AHRI 211729105None on this board (0 of 19 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons95.5(50 is the typical model of its size class)1U12EH2VHE*with ductless indoor unit AW12EH2VHD15 of 25 models qualify · AHRI 206389351No models in this size class
Non-ducted, 2 tons61.1(50 is the typical model of its size class)3U24EH2HD**4 of 9 models qualify · AHRI 210082198No models in this size class
Non-ducted, 2.5–3 tons67.0(50 is the typical model of its size class)4U36EH2HD**3 of 6 models qualify · AHRI 210082201No models in this size class
Non-ducted, 3.5–4.5 tons19.2(50 is the typical model of its size class)1U4248LP2HD**with ductless indoor unit USYL42UCDD1 of 4 models qualify · AHRI 211744605No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHAIERAll-around score, best modelJANITROLAll-around score, best model
Ducted, up to 1.5 tons44.7(50 is the typical model of its size class) (higher)1U09EH2HE**with ducted air handler USYM09UCDSA5 of 6 models have all five ratings · AHRI 21240947240.0(50 is the typical model of its size class)GSZB401810A*with ducted air handler CAPTA3626*4A*+MBVC1201**-1AAlso listed as GSZM401810A3 of 3 models have all five ratings · AHRI 212836160
Ducted, 2 tons53.8(50 is the typical model of its size class)3U24EH2HD**3 of 5 models have all five ratings · AHRI 21008219959.1(50 is the typical model of its size class) (higher)GSZC702410A*with ducted air handler AMVT30BP1400A6 of 8 models have all five ratings · AHRI 211945057
Ducted, 2.5–3 tons44.5(50 is the typical model of its size class)4U36EH2HD**4 of 6 models have all five ratings · AHRI 21015102764.2(50 is the typical model of its size class) (higher)GSZC703610A*with ducted air handler CAPTA4230*4A*+MBVC2001**-1A11 of 15 models have all five ratings · AHRI 211945087
Ducted, 3.5–4.5 tons38.5(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD4 of 5 models have all five ratings · AHRI 21172910568.2(50 is the typical model of its size class) (higher)GSZC704810A*with ducted air handler CAPT4961*4A*+MBVC2001**-1A10 of 19 models have all five ratings · AHRI 211945125
Ducted, 5 tons and upNo models in this size class51.5(50 is the typical model of its size class)GPHH56041A*2 of 2 models have all five ratings · AHRI 211944535
Non-ducted, up to 1.5 tons95.2(50 is the typical model of its size class)1U09EH2VHE*with ductless indoor unit AW09EH2VHD22 of 25 models have all five ratings · AHRI 206445819No models in this size class
Non-ducted, 2 tons59.8(50 is the typical model of its size class)3U24MS2HD**7 of 9 models have all five ratings · AHRI 207698998No models in this size class
Non-ducted, 2.5–3 tons48.7(50 is the typical model of its size class)4U36EH2HD**5 of 6 models have all five ratings · AHRI 210082201No models in this size class
Non-ducted, 3.5–4.5 tons18.3(50 is the typical model of its size class)5U42MS2HD**4 of 4 models have all five ratings · AHRI 210404027No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHAIERJANITROL
COP at 5°Fbeats 93% · 2.311U12EH2VHE*Non-ducted, up to 1.5 tonsbeats 94% · 2.51GPHH56041A*Ducted, 5 tons and up
Capacity retention at 5°Fbeats 97% · 120%1U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 38% · 60%GSZC706010A*Ducted, 3.5–4.5 tons
HSPF2beats 99% · 14.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 55% · 8.2GSZC704810A*Ducted, 3.5–4.5 tons
SEER2beats 100% · 30.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 81% · 17.2GSZC704810A*Ducted, 3.5–4.5 tons
EER2beats 97% · 16.01U09EH2VHE*Non-ducted, up to 1.5 tonsbeats 92% · 12.5GSZB404810A*Ducted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 94% · 18,500 Btu/h2U20EH2HD**Non-ducted, up to 1.5 tonsbeats 40% · 30,600 Btu/hGSZC706010A*Ducted, 3.5–4.5 tons

More comparisons