Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Hisense vs TCL heat pumps
Measured against models of the same size and duct type, Hisense scores higher on 4 of the 6 ratings. Hisense has 159 outdoor models, TCL has 52 outdoor models. TCL has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Hisense
- TCL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Hisense | TCL |
|---|---|---|
| Efficiency index | 57% (higher)median — · 10th ranked | 43% (higher)median — |
| COP at 5°F | 40%median 1.80 · 26th ranked | 48%median 1.90 |
| Capacity retention at 5°F | 55% (higher)median 72% · 16th ranked | 43% (higher)median 70% |
| HSPF2 | 42% (higher)median 9.0 · 20th ranked | 31% (higher)median 8.5 |
| SEER2 | 50% (higher)median 20.5 · 15th ranked | 38% (higher)median 19.0 |
| EER2 | 56% (higher)median 12.5 · 13th ranked | 30% (higher)median 10.0 |
| Heating capacity at 5°F | 45%median 9,600 Btu/h · 20th ranked | 50%median 16,720 Btu/h |
| Outdoor models | 159 | 52 |
| AHRI certifications | 369 | 229 |
Share of models meeting each standard
| Standard | Hisense | TCL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 64.8%103 models | 42.3%22 models |
| CEE 2026 Tier 1 (Split ASHP) | 64.8%103 models | 38.5%20 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 59.1%94 models | 36.5%19 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 47.2%75 models | 23.1%12 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Hisense
- TCL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Hisense | TCL |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 46% | 1 · index 31% |
| Ducted, 2 tons | 3 · index 57% | 5 · index 53% |
| Ducted, 2.5–3 tons | 5 · index 65% | 4 · index 49% |
| Ducted, 3.5–4.5 tons | 6 · index 58% | 3 · index 55% |
| Non-ducted, up to 1.5 tons | 114 · index 59% | 23 · index 38% |
| Non-ducted, 2 tons | 24 · index 53% | 8 · index 47% |
| Non-ducted, 2.5–3 tons | 10 · index 63% | 8 · index 35% |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | HisenseCold-climate score, best model | TCLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)AUW-09U3SSwith ducted air handler ADT-09UX3SBL4 of 4 models qualify · AHRI 204835479 | 56.1(50 is the typical model of its size class) (higher)THH18HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 1 models qualify · AHRI 212400611 |
| Ducted, 2 tons | 65.6(50 is the typical model of its size class) (higher)AUWR-24U3SF2with ducted air handler A(E,F)M304+TDR4 of 4 models qualify · AHRI 214447344 | 55.3(50 is the typical model of its size class)THH24HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 2 models qualify · AHRI 212390892 |
| Ducted, 2.5–3 tons | 78.9(50 is the typical model of its size class) (higher)AUWR-36U3SAwith ducted air handler HE35936+TD5 of 5 models qualify · AHRI 215333846 | 66.7(50 is the typical model of its size class)TCU-36D7HEWA/DV2Owith ducted air handler TCU-36D7HWA/DV2I6 of 6 models qualify · AHRI 207827230 |
| Ducted, 3.5–4.5 tons | 74.5(50 is the typical model of its size class) (higher)AUWR-60U3SP2with ducted air handler L(E,G)M60I44 of 6 models qualify · AHRI 213896272 | 62.3(50 is the typical model of its size class)TCE-60HA/DV2Owith ducted air handler TCE-60D7HWA/DV2I4 of 4 models qualify · AHRI 201864499 |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class) (higher)AUW-09U3SSwith ductless indoor unit ACT-09UR3SCA72 of 114 models qualify · AHRI 204835478 | 68.8(50 is the typical model of its size class)TSC-12HA2/I3TI23with ductless indoor unit TSC-12HA2/I3TI23-I10 of 23 models qualify · AHRI 207688890 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class)AUW-24U3SAwith ductless indoor unit ACT-24UR3SGB14 of 24 models qualify · AHRI 203167189 | None on this board (0 of 8 models qualify) |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class)AUW-36U3ST1with ductless indoor unit AUC-36UR3SHB12 of 10 models qualify · AHRI 205141567 | None on this board (0 of 8 models qualify) |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class)AMW5-42U3STA1 of 1 models qualify · AHRI 205123813 | No models in this size class |
All-around best
| Size and duct type | HisenseAll-around score, best model | TCLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 57.7(50 is the typical model of its size class) (higher)AUW-09U3SSwith ducted air handler ADT-09UX3SBL4 of 4 models have all five ratings · AHRI 204835479 | 30.7(50 is the typical model of its size class)THH18HAI2NAF2U23with ducted air handler 4TXCB003DS31 of 1 models have all five ratings · AHRI 212400611 |
| Ducted, 2 tons | 71.6(50 is the typical model of its size class)AMW3-24U3SAA4 of 4 models have all five ratings · AHRI 203446790 | 76.7(50 is the typical model of its size class) (higher)TCU-36D7HEWA/DV2Owith ducted air handler TCU-24D7HWA/DV2I4 of 4 models have all five ratings · AHRI 207827229 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class) (higher)AMW4-36U3STA5 of 5 models have all five ratings · AHRI 203459336 | 67.3(50 is the typical model of its size class)TCE-60HA/DV2Owith ducted air handler TCU-36D7HWA/DV2I6 of 6 models have all five ratings · AHRI 211869249 |
| Ducted, 3.5–4.5 tons | 65.5(50 is the typical model of its size class)AUWR-48U3SPwith ducted air handler DC61A44-245R6 of 6 models have all five ratings · AHRI 213411088 | 74.0(50 is the typical model of its size class) (higher)TCU-60D7HEWA/DV2Owith ducted air handler TCU-48D7HWA/DV2I2 of 2 models have all five ratings · AHRI 207827118 |
| Non-ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)AS-09UW3SXE00with ductless indoor unit AS-09UW3SXE**0082 of 114 models have all five ratings · AHRI 201981253 | 70.8(50 is the typical model of its size class)TSC-12HA2/I3TI23with ductless indoor unit TSC-12HA2/I3TI23-I14 of 23 models have all five ratings · AHRI 207688890 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class) (higher)AMW3-24U3SAAwith ductless indoor unit AST-07UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**0014 of 24 models have all five ratings · AHRI 202864314 | 61.7(50 is the typical model of its size class)TUM-27HA2/I2I21-21ES3 of 8 models have all five ratings · AHRI 209424844 |
| Non-ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class) (higher)AMW4-36U3STAwith ductless indoor unit AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**00+AST-09UW3SVE**002 of 10 models have all five ratings · AHRI 202911535 | 65.0(50 is the typical model of its size class)TUM-36HA2/I2I21-21ES5 of 8 models have all five ratings · AHRI 209424845 |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)AMW5-42U3STA1 of 1 models have all five ratings · AHRI 205123812 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Hisense | TCL |
|---|---|---|
| COP at 5°F | beats 97% · 2.80AUWR-24U3SF2Ducted, up to 1.5 tons | beats 98% · 2.27TUM-27HA2/I2I21-21ESNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 99% · 113%AMW4-36U3STANon-ducted, 2.5–3 tons | beats 100% · 142%THH24HAI2NAF2U23Ducted, 2 tons |
| HSPF2 | beats 83% · 9.5AUW-36U3ST1Ducted, 2.5–3 tons | beats 73% · 9.2TCU-60D7HEWA/DV2ODucted, 2.5–3 tons |
| SEER2 | beats 96% · 27.5AS-09UR3SXE00Also listed as AS-09UW3SXE00B, AS-09UW3SXETG00G, AS-09UW3SXETG00P, AS-09UW3SXETG00Non-ducted, up to 1.5 tons | beats 94% · 20.0TCU-36D7HEWA/DV2ODucted, 2 tons |
| EER2 | beats 93% · 15.5AS-09UR3SXE00Also listed as AS-09UW3SXE00B, AS-09UW3SXETG00G, AS-09UW3SXETG00P, AS-09UW3SXETG00Non-ducted, up to 1.5 tons | beats 95% · 13.0TCU-36D7HEWA/DV2ODucted, 2 tons |
| Heating capacity at 5°F | beats 98% · 31,000 Btu/hAUWR-24U3SF2Ducted, 2 tons | beats 100% · 34,000 Btu/hTHH18HAI2NAF2U23Ducted, up to 1.5 tons |