Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Innovair vs RUSSELL heat pumps
Measured against models of the same size and duct type, Innovair scores higher on 4 of the 6 ratings. Innovair has 44 outdoor models, RUSSELL has 60 outdoor models. RUSSELL has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Innovair
- RUSSELL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Innovair | RUSSELL |
|---|---|---|
| Efficiency index | 56% (higher)median — · 12th ranked | 49% (higher)median — |
| COP at 5°F | 51%median 1.91 · 17th ranked | 80%median 2.20 |
| Capacity retention at 5°F | 64% (higher)median 82% · 6th ranked | 43% (higher)median 57% |
| HSPF2 | 53% (higher)median 8.8 · 13th ranked | 25% (higher)median 7.2 |
| SEER2 | 50% (higher)median 17.0 · 12th ranked | 32% (higher)median 14.3 |
| EER2 | 42%median 10.6 · 25th ranked | 42%median 10.6 |
| Heating capacity at 5°F | 64% (higher)median 21,555 Btu/h · 4th ranked | 42% (higher)median 24,200 Btu/h |
| Outdoor models | 44 | 60 |
| AHRI certifications | 91 | 1,231 |
Share of models meeting each standard
| Standard | Innovair | RUSSELL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 52.3%23 models | 16.7%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 47.7%21 models | 16.7%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 3.3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 47.7%21 models | 13.3%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 3.3%2 models |
| ENERGY STAR Cold Climate | 52.3%23 models | 21.7%13 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Innovair
- RUSSELL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Innovair | RUSSELL |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 53% | 2 · index 27% |
| Ducted, 2 tons | 5 · index 63% | 7 · index 52% |
| Ducted, 2.5–3 tons | 7 · index 51% | 17 · index 52% |
| Ducted, 3.5–4.5 tons | 6 · index 53% | 26 · index 50% |
| Ducted, 5 tons and up | 1 · index 42% | 8 · index 70% |
| Non-ducted, up to 1.5 tons | 11 · index 68% | None |
| Non-ducted, 2 tons | 5 · index 68% | None |
| Non-ducted, 2.5–3 tons | 7 · index 44% | None |
| Non-ducted, 3.5–4.5 tons | 1 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | InnovairCold-climate score, best model | RUSSELLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597 | None on this board (0 of 2 models qualify) |
| Ducted, 2 tons | 75.6(50 is the typical model of its size class) (higher)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430 | 74.7(50 is the typical model of its size class)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU2 of 7 models qualify · AHRI 213372369 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476 | 80.6(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACA2 of 17 models qualify · AHRI 210106900 |
| Ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157 | 76.3(50 is the typical model of its size class) (higher)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S962V1005A21M4S4 of 26 models qualify · AHRI 210106968 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | None on this board (0 of 8 models qualify) |
| Non-ducted, up to 1.5 tons | 80.1(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models qualify · AHRI 206330207 | No models in this size class |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210 | No models in this size class |
| Non-ducted, 2.5–3 tons | 64.0(50 is the typical model of its size class)VOM36H7R4P71 of 7 models qualify · AHRI 207821954 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958 | No models in this size class |
All-around best
| Size and duct type | InnovairAll-around score, best model | RUSSELLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.8(50 is the typical model of its size class) (higher)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 213255597 | 34.5(50 is the typical model of its size class)SP15AZ18AJ2Nwith ducted air handler SH2CZ2417STANN2 of 2 models have all five ratings · AHRI 211627516 |
| Ducted, 2 tons | 71.6(50 is the typical model of its size class)VOM24H7R3P75 of 5 models have all five ratings · AHRI 207821950 | 83.6(50 is the typical model of its size class) (higher)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU4 of 7 models have all five ratings · AHRI 213372369 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)VOM36H7R4P77 of 7 models have all five ratings · AHRI 207821953 | 87.2(50 is the typical model of its size class) (higher)SP18AZ36AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z6 of 17 models have all five ratings · AHRI 210589394 |
| Ducted, 3.5–4.5 tons | 60.7(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 207821956 | 80.3(50 is the typical model of its size class) (higher)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z9 of 26 models have all five ratings · AHRI 210589350 |
| Ducted, 5 tons and up | 41.7(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 208106863 | 70.2(50 is the typical model of its size class) (higher)SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHS1 of 8 models have all five ratings · AHRI 212387320 |
| Non-ducted, up to 1.5 tons | 88.7(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 11 models have all five ratings · AHRI 206330207 | No models in this size class |
| Non-ducted, 2 tons | 76.3(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models have all five ratings · AHRI 206330210 | No models in this size class |
| Non-ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class)VOM36H7R4P75 of 7 models have all five ratings · AHRI 207821954 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 44.5(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Innovair | RUSSELL |
|---|---|---|
| COP at 5°F | beats 91% · 2.37VEA36H2V18Ducted, 2.5–3 tons | beats 98% · 2.60SP15AZ60AJ2NDucted, 5 tons and up |
| Capacity retention at 5°F | beats 99% · 144%EIN10H2V32(O)Non-ducted, up to 1.5 tons | beats 100% · 105%SP18AZ48AJVCDucted, 3.5–4.5 tons |
| HSPF2 | beats 93% · 10.8SHV18H2R20Ducted, up to 1.5 tons | beats 75% · 9.5RD17AZ24AJ3NDucted, 2 tons |
| SEER2 | beats 96% · 21.0VOM24H7R3P7Ducted, 2 tons | beats 94% · 20.0SP18AZ24AJVCDucted, 2 tons |
| EER2 | beats 99% · 16.6EIN10H2V32(O)Non-ducted, up to 1.5 tons | beats 91% · 12.5SP18AZ36AJVCDucted, 2.5–3 tons |
| Heating capacity at 5°F | beats 96% · 20,000 Btu/hEIN18H2V32(O)Non-ducted, up to 1.5 tons | beats 100% · 43,500 Btu/hSP18AZ36AJVCDucted, 2.5–3 tons |