Skip to content

KADEN vs LPS Legacy heat pumps

Measured against models of the same size and duct type, KADEN scores higher on 4 of the 6 ratings. KADEN has 24 outdoor models, LPS Legacy has 58 outdoor models. KADEN and LPS Legacy have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
KADEN and LPS Legacy on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KADEN scores higher on 4 of the 6 ratings.
  • KADEN
  • LPS Legacy
  • Other ranked manufacturers
KADENLPS Lega…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingKADENLPS Legacy
Efficiency index58% (higher)median —53% (higher)median —
COP at 5°F52% (higher)median 2.0051% (higher)median 1.97
Capacity retention at 5°F41%median 65%49%median 67%
HSPF269% (higher)median 9.362% (higher)median 9.2
SEER274% (higher)median 19.355% (higher)median 18.5
EER249% (higher)median 10.942% (higher)median 10.6
Heating capacity at 5°F44%median 18,250 Btu/h50%median 19,000 Btu/h
Outdoor models2458
AHRI certifications37146

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardKADENLPS Legacy
CEE 2025 Tier 1 (Split ASHP)66.7%16 models58.6%34 models
CEE 2026 Tier 1 (Split ASHP)54.2%13 models55.2%32 models
CEE Advanced Tier (Split ASHP)0%0 models3.4%2 models
Xcel Energy Colorado cold-climate ASHP (2025)25%6 models39.7%23 models
DOE Cold Climate Heat Pump Challenge0%0 models3.4%2 models
ENERGY STAR Cold Climate25%6 models43.1%25 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 9 groups where both have models
  • KADEN
  • LPS Legacy
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeKADENLPS Legacy
Ducted, up to 1.5 tons3 · index 42%6 · index 61%
Ducted, 2 tons2 · index 52%4 · index 65%
Ducted, 2.5–3 tons6 · index 52%13 · index 53%
Ducted, 3.5–4.5 tons4 · index 55%8 · index 54%
Ducted, 5 tons and up2 · index 42%3 · index 51%
Non-ducted, up to 1.5 tons7 · index 73%20 · index 53%
Non-ducted, 2 tons1 · index 78%4 · index 47%
Non-ducted, 2.5–3 tons2 · index 69%13 · index 47%
Non-ducted, 3.5–4.5 tons2 · index 49%7 · index 46%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeKADENCold-climate score, best modelLPS LegacyCold-climate score, best model
Ducted, up to 1.5 tons52.0(50 is the typical model of its size class)KO-PS218HP-2AAMA1 of 3 models qualify · AHRI 21179356181.3(50 is the typical model of its size class) (higher)DLCSRBH18AAKwith ducted air handler DLFSDAH18XHK5 of 6 models qualify · AHRI 211756586
Ducted, 2 tons62.9(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models qualify · AHRI 21179354979.4(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models qualify · AHRI 211756579
Ducted, 2.5–3 tonsNone on this board (0 of 6 models qualify)78.6(50 is the typical model of its size class)DLCURAH36ABKwith ducted air handler DLFULAH36XCX + CI3 of 13 models qualify · AHRI 213372201
Ducted, 3.5–4.5 tonsNone on this board (0 of 4 models qualify)74.9(50 is the typical model of its size class)DLCURAH48ABKwith ducted air handler DLFUAAH60XAK4 of 8 models qualify · AHRI 217197708
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons89.3(50 is the typical model of its size class)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA2 of 7 models qualify · AHRI 21326555695.0(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAK11 of 20 models qualify · AHRI 211756581
Non-ducted, 2 tons60.4(50 is the typical model of its size class)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models qualify · AHRI 21179355986.1(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ductless indoor unit DLFSCBH24XAK2 of 4 models qualify · AHRI 211756560
Non-ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)73.4(50 is the typical model of its size class)DLCMHBH36DAK2 of 13 models qualify · AHRI 211756577
Non-ducted, 3.5–4.5 tonsNone on this board (0 of 2 models qualify)80.5(50 is the typical model of its size class)DLCMHBH48EAK3 of 7 models qualify · AHRI 211756575

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeKADENAll-around score, best modelLPS LegacyAll-around score, best model
Ducted, up to 1.5 tons59.4(50 is the typical model of its size class)KO-PS218HP-2AAMA3 of 3 models have all five ratings · AHRI 21179356185.2(50 is the typical model of its size class) (higher)DLCSRBH09AAKwith ducted air handler DLFSDAH09XAK6 of 6 models have all five ratings · AHRI 211756568
Ducted, 2 tons52.0(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models have all five ratings · AHRI 21179354980.1(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ducted air handler DLFSDAH24XAK4 of 4 models have all five ratings · AHRI 211756579
Ducted, 2.5–3 tons75.4(50 is the typical model of its size class) (higher)KO-PS327HP-2AAMA6 of 6 models have all five ratings · AHRI 21179356472.0(50 is the typical model of its size class)DLCMHBH30DAK12 of 13 models have all five ratings · AHRI 211756500
Ducted, 3.5–4.5 tons63.5(50 is the typical model of its size class)KO-PS548HP-2AAMA4 of 4 models have all five ratings · AHRI 21179356882.0(50 is the typical model of its size class) (higher)DLCMHBH48EAK7 of 8 models have all five ratings · AHRI 211756576
Ducted, 5 tons and up41.7(50 is the typical model of its size class)KO-UUS60HP-2AAMAwith ducted air handler KI-UUS60AHU-2AAMAAlso listed as KO-UUX60HP-2AAMA2 of 2 models have all five ratings · AHRI 21179355357.1(50 is the typical model of its size class) (higher)DLCLRCH58AAKwith ducted air handler DLFLDAH58XHK3 of 3 models have all five ratings · AHRI 211756477
Non-ducted, up to 1.5 tons92.0(50 is the typical model of its size class)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA7 of 7 models have all five ratings · AHRI 21326555693.6(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAK20 of 20 models have all five ratings · AHRI 211756581
Non-ducted, 2 tons77.5(50 is the typical model of its size class)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models have all five ratings · AHRI 21179355984.3(50 is the typical model of its size class) (higher)DLCSRBH24AAKwith ductless indoor unit DLFSHCH24XAK4 of 4 models have all five ratings · AHRI 211756584
Non-ducted, 2.5–3 tons78.2(50 is the typical model of its size class) (higher)KO-PS327HP-2AAMA2 of 2 models have all five ratings · AHRI 21179356370.8(50 is the typical model of its size class)DLCMHBH36DAK11 of 13 models have all five ratings · AHRI 211756577
Non-ducted, 3.5–4.5 tons56.1(50 is the typical model of its size class)KO-PS548HP-2AAMA2 of 2 models have all five ratings · AHRI 21179356773.8(50 is the typical model of its size class) (higher)DLCMHBH48EAK5 of 7 models have all five ratings · AHRI 211756575

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingKADENLPS Legacy
COP at 5°Fbeats 97% · 2.39KO-PSX12HP-2AAMANon-ducted, up to 1.5 tonsbeats 99% · 2.89DLCPRBH18AAKNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 92% · 107%KO-PSX06HP-2AAMANon-ducted, up to 1.5 tonsbeats 97% · 120%DLCPRBH18AAKNon-ducted, up to 1.5 tons
HSPF2beats 98% · 13.6KO-PSX06HP-2AAMANon-ducted, up to 1.5 tonsbeats 100% · 15.0DLCPRBH09AAKNon-ducted, up to 1.5 tons
SEER2beats 99% · 24.6KO-PS327HP-2AAMANon-ducted, 2.5–3 tonsbeats 99% · 20.9DLCMHBH48EAKDucted, 3.5–4.5 tons
EER2beats 97% · 14.0KO-PSX24HP-2AAMANon-ducted, 2 tonsbeats 98% · 16.2DLCSRBH09AAKNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 79% · 13,100 Btu/hKO-PSX18HP-2AAMANon-ducted, up to 1.5 tonsbeats 100% · 24,000 Btu/hDLCPRBH18AAKNon-ducted, up to 1.5 tons

More comparisons