Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
LG vs MRCOOL heat pumps
Measured against models of the same size and duct type, LG scores higher on 6 of the 6 ratings. LG has 78 outdoor models, MRCOOL has 111 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- LG
- MRCOOL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | LG | MRCOOL |
|---|---|---|
| Efficiency index | 65% (higher)median — · 2nd ranked | 54% (higher)median — · 15th ranked |
| COP at 5°F | 59% (higher)median 2.06 · 7th ranked | 49% (higher)median 1.94 · 18th ranked |
| Capacity retention at 5°F | 64% (higher)median 80% · 5th ranked | 41% (higher)median 64% · 24th ranked |
| HSPF2 | 70% (higher)median 9.5 · 3rd ranked | 51% (higher)median 8.6 · 15th ranked |
| SEER2 | 63% (higher)median 20.2 · 6th ranked | 50% (higher)median 16.6 · 12th ranked |
| EER2 | 69% (higher)median 12.5 · 1st ranked | 56% (higher)median 11.7 · 12th ranked |
| Heating capacity at 5°F | 67% (higher)median 19,900 Btu/h · 3rd ranked | 43% (higher)median 17,800 Btu/h · 21st ranked |
| Outdoor models | 78 | 111 |
| AHRI certifications | 175 | 361 |
Share of models meeting each standard
| Standard | LG | MRCOOL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 74.4%58 models | 46.8%52 models |
| CEE 2026 Tier 1 (Split ASHP) | 74.4%58 models | 43.2%48 models |
| CEE Advanced Tier (Split ASHP) | 9%7 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 67.9%53 models | 25.2%28 models |
| DOE Cold Climate Heat Pump Challenge | 9%7 models | 0%0 models |
| ENERGY STAR Cold Climate | 44.9%35 models | 22.5%25 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- LG
- MRCOOL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | LG | MRCOOL |
|---|---|---|
| Ducted, up to 1.5 tons | 11 · index 57% | 8 · index 55% |
| Ducted, 2 tons | 7 · index 71% | 13 · index 57% |
| Ducted, 2.5–3 tons | 9 · index 80% | 24 · index 55% |
| Ducted, 3.5–4.5 tons | 15 · index 79% | 27 · index 55% |
| Ducted, 5 tons and up | 3 · index 72% | 4 · index 41% |
| Non-ducted, up to 1.5 tons | 35 · index 54% | 23 · index 56% |
| Non-ducted, 2 tons | 10 · index 61% | 7 · index 56% |
| Non-ducted, 2.5–3 tons | 10 · index 69% | 10 · index 45% |
| Non-ducted, 3.5–4.5 tons | 11 · index 70% | 2 · index 49% |
| Non-ducted, 5 tons and up | 3 · index 55% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | LGCold-climate score, best model | MRCOOLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 78.7(50 is the typical model of its size class) (higher)LUU090HVwith ducted air handler LHN098HV18 of 11 models qualify · AHRI 212578846 | 73.5(50 is the typical model of its size class)DIYH-18-HP-C-230C25with ducted air handler DIYH-18-HP-MUAH-230C252 of 8 models qualify · AHRI 210295926 |
| Ducted, 2 tons | 92.9(50 is the typical model of its size class) (higher)ARUN024GSS45 of 7 models qualify · AHRI 10070563 | 69.5(50 is the typical model of its size class)CENTRAL-24-HP-C-230A00with ducted air handler CENTRAL-24-HP-MUAH230A005 of 11 models qualify · AHRI 211497151 |
| Ducted, 2.5–3 tons | 97.0(50 is the typical model of its size class) (higher)ARUN038GSS47 of 9 models qualify · AHRI 8717932 | 74.8(50 is the typical model of its size class)CENTRAL-36-HP-C-230A00with ducted air handler CENTRAL-36-HP-MUAH230A006 of 26 models qualify · AHRI 210279122 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class) (higher)LMU480HHV12 of 15 models qualify · AHRI 206717009 | 77.1(50 is the typical model of its size class)CENTRAL-60-HP-C-230A00with ducted air handler CENTRAL-60-HP-MUAH230A006 of 27 models qualify · AHRI 210279124 |
| Ducted, 5 tons and up | 81.7(50 is the typical model of its size class)LMU601HV2 of 3 models qualify · AHRI 206717003 | None on this board (0 of 4 models qualify) |
| Non-ducted, up to 1.5 tons | 95.4(50 is the typical model of its size class) (higher)LAU090HYV3with ductless indoor unit LAN090HYV322 of 35 models qualify · AHRI 204825177 | 86.0(50 is the typical model of its size class)O-ES-09-HP-C-230Bwith ductless indoor unit O-09-HP-WMAH-230B8 of 23 models qualify · AHRI 208552810 |
| Non-ducted, 2 tons | 92.9(50 is the typical model of its size class) (higher)ARUN024GSS47 of 10 models qualify · AHRI 10070562 | 84.5(50 is the typical model of its size class)O-HH-24-HP-C-230Awith ductless indoor unit O-24-HP-WMAH-230BAlso listed as O-HH-24-HP-C-230B3 of 7 models qualify · AHRI 207339164 |
| Non-ducted, 2.5–3 tons | 92.2(50 is the typical model of its size class) (higher)ARUN038GSS47 of 10 models qualify · AHRI 8717931 | 53.7(50 is the typical model of its size class)DIY-MULTI3-27HP230C1 of 10 models qualify · AHRI 207339195 |
| Non-ducted, 3.5–4.5 tons | 97.4(50 is the typical model of its size class)LMU421HHV8 of 11 models qualify · AHRI 206717001 | None on this board (0 of 2 models qualify) |
| Non-ducted, 5 tons and up | 71.5(50 is the typical model of its size class)ARUB060GSS43 of 3 models qualify · AHRI 10271659 | No models in this size class |
All-around best
| Size and duct type | LGAll-around score, best model | MRCOOLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 64.8(50 is the typical model of its size class) (higher)LUU180HHVwith ducted air handler LVN181HV48 of 11 models have all five ratings · AHRI 205788774 | 59.4(50 is the typical model of its size class)MULTI2-18HP230B4 of 8 models have all five ratings · AHRI 208552830 |
| Ducted, 2 tons | 86.9(50 is the typical model of its size class) (higher)ARUN024GSS46 of 7 models have all five ratings · AHRI 10070563 | 68.2(50 is the typical model of its size class)DIYH-24-HP-C-230C25with ducted air handler DIYH-24-HP-MUAH-230C2510 of 13 models have all five ratings · AHRI 210288098 |
| Ducted, 2.5–3 tons | 97.5(50 is the typical model of its size class) (higher)ARUN038GSS48 of 9 models have all five ratings · AHRI 8717932 | 75.4(50 is the typical model of its size class)MULTI3-27HP230B14 of 24 models have all five ratings · AHRI 208552953 |
| Ducted, 3.5–4.5 tons | 89.8(50 is the typical model of its size class) (higher)LMU480HHV15 of 15 models have all five ratings · AHRI 206717009 | 69.0(50 is the typical model of its size class)MHP17048A-**Awith indoor coil MCHP51CNPA*+TDR+TXV and furnace MGM80SE090C5A16 of 27 models have all five ratings · AHRI 211737253 |
| Ducted, 5 tons and up | 78.9(50 is the typical model of its size class) (higher)LMU601HV2 of 3 models have all five ratings · AHRI 206717003 | 62.6(50 is the typical model of its size class)MHP17060A-**Awith indoor coil MCVP60CNPA+TDR and furnace MGM80SE090C5A2 of 4 models have all five ratings · AHRI 212619860 |
| Non-ducted, up to 1.5 tons | 95.3(50 is the typical model of its size class) (higher)LAU090HYV3with ductless indoor unit LAN090HYV331 of 35 models have all five ratings · AHRI 204825177 | 88.4(50 is the typical model of its size class)O-ES-09-HP-C-230Bwith ductless indoor unit O-09-HP-WMAH-230B23 of 23 models have all five ratings · AHRI 208552810 |
| Non-ducted, 2 tons | 88.3(50 is the typical model of its size class) (higher)LAU240HYV3with ductless indoor unit LAN240HYV39 of 10 models have all five ratings · AHRI 204825181 | 84.3(50 is the typical model of its size class)O-HH-24-HP-C-230Awith ductless indoor unit O-24-HP-WMAH-230BAlso listed as O-HH-24-HP-C-230B7 of 7 models have all five ratings · AHRI 207339164 |
| Non-ducted, 2.5–3 tons | 87.4(50 is the typical model of its size class) (higher)LMU361HHV10 of 10 models have all five ratings · AHRI 206717007 | 78.2(50 is the typical model of its size class)MULTI3-27HP230B7 of 10 models have all five ratings · AHRI 208552834 |
| Non-ducted, 3.5–4.5 tons | 92.1(50 is the typical model of its size class) (higher)LMU421HHV11 of 11 models have all five ratings · AHRI 206717001 | 56.1(50 is the typical model of its size class)MULTI5-48HP230B2 of 2 models have all five ratings · AHRI 208552838 |
| Non-ducted, 5 tons and up | 61.0(50 is the typical model of its size class)LMU601HV3 of 3 models have all five ratings · AHRI 206717015 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | LG | MRCOOL |
|---|---|---|
| COP at 5°F | beats 100% · 3.19ARUN038GSS4Non-ducted, 2.5–3 tons | beats 97% · 2.39O-ES-12-HP-C-230BNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 114%ARUM036GSS5Non-ducted, 2.5–3 tons | beats 97% · 98%MDPH180484Ducted, 3.5–4.5 tons |
| HSPF2 | beats 99% · 9.5LMU601HVDucted, 5 tons and up | beats 98% · 9.8DIY-MULTI5-48HP230CDucted, 3.5–4.5 tons |
| SEER2 | beats 99% · 18.5LMU601HVDucted, 5 tons and up | beats 99% · 24.6MULTI3-27HP230BNon-ducted, 2.5–3 tons |
| EER2 | beats 100% · 15.5ARUM036GSS5Non-ducted, 2.5–3 tons | beats 99% · 14.0MHP17024A-**ADucted, 2 tons |
| Heating capacity at 5°F | beats 100% · 48,000 Btu/hARUM036GSS5Non-ducted, 2.5–3 tons | beats 99% · 54,356 Btu/hCENTRAL-60-HP-C-230A00Ducted, 3.5–4.5 tons |