Skip to content

Live cool vs TRUENORTH heat pumps

Measured against models of the same size and duct type, Live cool and TRUENORTH split the 6 ratings 3–3. Live cool has 6 outdoor models, TRUENORTH has 18 outdoor models. Live cool and TRUENORTH have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Live cool and TRUENORTH on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Live cool and TRUENORTH split the 6 ratings 3–3.
  • Live cool
  • TRUENORTH
  • Other ranked manufacturers
Live coolTRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLive coolTRUENORTH
Efficiency index52% (higher)median —41% (higher)median —
COP at 5°F23%median 1.8036%median 1.80
Capacity retention at 5°F50%median 73%54%median 71%
HSPF247% (higher)median 9.045% (higher)median 8.5
SEER268% (higher)median 22.541% (higher)median 17.5
EER263% (higher)median 12.833% (higher)median 10.3
Heating capacity at 5°F38%median 8,900 Btu/h56%median 17,400 Btu/h
Outdoor models618
AHRI certifications632

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLive coolTRUENORTH
CEE 2025 Tier 1 (Split ASHP)100%6 models50%9 models
CEE 2026 Tier 1 (Split ASHP)100%6 models44.4%8 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66.7%4 models38.9%7 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate66.7%4 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • Live cool
  • TRUENORTH
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLive coolTRUENORTH
Ducted, up to 1.5 tonsNone2 · index 30%
Ducted, 2 tonsNone2 · index 36%
Ducted, 2.5–3 tonsNone7 · index 41%
Ducted, 3.5–4.5 tonsNone2 · index 35%
Non-ducted, up to 1.5 tons5 · index 54%6 · index 33%
Non-ducted, 2 tons1 · index 46%2 · index 48%
Non-ducted, 2.5–3 tonsNone3 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLive coolCold-climate score, best modelTRUENORTHCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class35.6(50 is the typical model of its size class)WLWHD(18)ND3MO2 of 2 models qualify · AHRI 218593150
Ducted, 2 tonsNo models in this size class50.1(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593151
Ducted, 2.5–3 tonsNo models in this size class54.7(50 is the typical model of its size class)WLWHD(30)ND3MO5 of 7 models qualify · AHRI 218593152
Ducted, 3.5–4.5 tonsNo models in this size class51.6(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLCAT60H/NAA1 of 2 models qualify · AHRI 218461829
Non-ducted, up to 1.5 tons47.5(50 is the typical model of its size class)LWSM-12IR410AHS23with ductless indoor unit LWSM-12IR410AHS234 of 5 models qualify · AHRI 21803724073.1(50 is the typical model of its size class) (higher)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)76.1(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148
Non-ducted, 2.5–3 tonsNo models in this size class73.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLive coolAll-around score, best modelTRUENORTHAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class31.2(50 is the typical model of its size class)WLWHD(18)ND3MO2 of 2 models have all five ratings · AHRI 218593150
Ducted, 2 tonsNo models in this size class45.9(50 is the typical model of its size class)WLWHD(24)ND3MO2 of 2 models have all five ratings · AHRI 218593151
Ducted, 2.5–3 tonsNo models in this size class53.1(50 is the typical model of its size class)WLWHD(30)ND3MO6 of 6 models have all five ratings · AHRI 218593152
Ducted, 3.5–4.5 tonsNo models in this size class43.5(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLCAT60H/NAA3 of 3 models have all five ratings · AHRI 218461829
Non-ducted, up to 1.5 tons60.6(50 is the typical model of its size class) (higher)LWSM-09IR410AHS23with ductless indoor unit LWSM-09IR410AHS235 of 5 models have all five ratings · AHRI 21803723958.0(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147
Non-ducted, 2 tons46.0(50 is the typical model of its size class)LWSM-24IR410AHS20with ductless indoor unit LWSM-24IR410AHS201 of 1 models have all five ratings · AHRI 21803724271.5(50 is the typical model of its size class) (higher)WLWHD(24)ND3MO2 of 2 models have all five ratings · AHRI 218593148
Non-ducted, 2.5–3 tonsNo models in this size class70.2(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLive coolTRUENORTH
COP at 5°Fbeats 26% · 1.80LWSM-24IR410AHS20Non-ducted, 2 tonsbeats 89% · 2.21WLWHD(18)ND3MONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 64% · 77%LWSM-09IR410AHS23Non-ducted, up to 1.5 tonsbeats 85% · 89%WLWHD(30)ND3MODucted, 2.5–3 tons
HSPF2beats 57% · 9.5LWSM-12IR410AHS23Non-ducted, up to 1.5 tonsbeats 82% · 10.0WLWHD(36)ND3MONon-ducted, 2.5–3 tons
SEER2beats 79% · 23.5LWSM-09IR410AHS23Non-ducted, up to 1.5 tonsbeats 66% · 21.0WLWHD(24)ND3MONon-ducted, 2 tons
EER2beats 68% · 13.0LWSM-09IR410AHS23Non-ducted, up to 1.5 tonsbeats 84% · 12.5WLWHD(30)ND3MONon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 66% · 11,900 Btu/hLWSM-18IR410AHS21.5Non-ducted, up to 1.5 tonsbeats 84% · 13,800 Btu/hWLWHD(18)ND3MONon-ducted, up to 1.5 tons

More comparisons