Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
1HVAC vs TGM: heat pump ratings compared
Against heat pumps of the same size and type, a typical 1HVAC model beats 54% and a typical TGM model 52%. 1HVAC rates slightly higher overall.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
1HVAC
54%
of similar heat pumps beaten by its typical model
About average87 models listed
TGM
52%
of similar heat pumps beaten by its typical model
About average54 models listed
- Efficiency on a 5°F dayCOP at 5°F1HVAC: Beats 44%TGM: Beats 43%
- Heating power kept at 5°FCapacity at 5°F vs 47°F1HVAC: Beats 62%TGM: Beats 47%
- Winter-long heating efficiencyHSPF21HVAC: Beats 61%TGM: Beats 46%
- Summer-long cooling efficiencySEER21HVAC: Beats 59%TGM: Beats 47%
- Hot-day cooling efficiencyEER21HVAC: Beats 43%TGM: Beats 47%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- 1HVAC
- 63%
- TGM
- 32%
Xcel CC
- 1HVAC
- 55%
- TGM
- 24%
CEE Advanced
- 1HVAC
- 1%
- TGM
- 0%
ENERGY STAR CC
- 1HVAC
- 41%
- TGM
- 13%
Top cold-climate picks, ducted up to 1.5 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
1HVAC
- 1ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM1HVAC1.5 tons · 18,000 Btu/h · DuctedKeeps 99% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 99% (Capacity at 5°F vs 47°F)
- Great
- Efficiency at 5°F
- 2.30 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.8 (HSPF2)
- Top 10%
- 2ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB1HVAC1 ton · 9,000 Btu/h · DuctedKeeps 108% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 108% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.90 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 12.0 (HSPF2)
- Top 10%
- 3ACIQ-12ZPL-HP230Bwith ducted air handler ACIQ-12CD-HH-MB1HVAC1 ton · 12,000 Btu/h · DuctedKeeps 101% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 101% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.96 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 10.0 (HSPF2)
- Great
TGM
- 1MRSVHT12ASwith ducted air handler MFCHT12STGM1 ton · 11,500 Btu/h · DuctedKeeps 70% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.26 (COP at 5°F)
- Great
- Seasonal efficiency
- 10.3 (HSPF2)
- Great
- 2MMRSHT18AS2TGM1.5 tons · 18,000 Btu/h · DuctedKeeps 74% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 74% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 9.8 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view