Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BROCK vs Senville heat pumps
Measured against models of the same size and duct type, Senville scores higher on 4 of the 6 ratings. BROCK has 24 outdoor models, Senville has 27 outdoor models. BROCK has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BROCK
- Senville
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BROCK | Senville |
|---|---|---|
| Efficiency index | 42%median — | 61%median — · 7th ranked |
| COP at 5°F | 62% (higher)median 2.17 | 44% (higher)median 1.91 · 22nd ranked |
| Capacity retention at 5°F | 14%median 46% | 60%median 82% · 7th ranked |
| HSPF2 | 26%median 7.5 | 67%median 9.5 · 6th ranked |
| SEER2 | 32%median 14.9 | 67%median 21.4 · 3rd ranked |
| EER2 | 68% (higher)median 11.9 | 56% (higher)median 11.7 · 11th ranked |
| Heating capacity at 5°F | 16%median 17,150 Btu/h | 58%median 20,000 Btu/h · 7th ranked |
| Outdoor models | 24 | 27 |
| AHRI certifications | 2,986 | 59 |
Share of models meeting each standard
| Standard | BROCK | Senville |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 16.7%4 models | 70.4%19 models |
| CEE 2026 Tier 1 (Split ASHP) | 12.5%3 models | 63%17 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 3.7%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 44.4%12 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 3.7%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 51.9%14 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BROCK
- Senville
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BROCK | Senville |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 39% | 5 · index 63% |
| Ducted, 2 tons | 3 · index 38% | 2 · index 73% |
| Ducted, 2.5–3 tons | 7 · index 40% | 5 · index 69% |
| Ducted, 3.5–4.5 tons | 10 · index 42% | 4 · index 63% |
| Ducted, 5 tons and up | 3 · index 65% | None |
| Non-ducted, up to 1.5 tons | None | 10 · index 54% |
| Non-ducted, 2 tons | None | 2 · index 50% |
| Non-ducted, 2.5–3 tons | None | 9 · index 60% |
| Non-ducted, 3.5–4.5 tons | None | 2 · index 67% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BROCKCold-climate score, best model | SenvilleCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 74.9(50 is the typical model of its size class)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models qualify · AHRI 207641345 |
| Ducted, 2 tons | None on this board (0 of 3 models qualify) | 79.4(50 is the typical model of its size class)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models qualify · AHRI 207641348 |
| Ducted, 2.5–3 tons | None on this board (0 of 7 models qualify) | 79.9(50 is the typical model of its size class)SENA-36HF-MOB3 of 5 models qualify · AHRI 213732657 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 10 models qualify) | 74.9(50 is the typical model of its size class)SENA-48HF-MOB3 of 4 models qualify · AHRI 213732660 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 77.5(50 is the typical model of its size class)SENA/12HF/OQwith ductless indoor unit SENA/12HF/IQ4 of 10 models qualify · AHRI 207571419 |
| Non-ducted, 2 tons | No models in this size class | 86.1(50 is the typical model of its size class)SENA/24HF/OQwith ductless indoor unit SENA/24HF/ICQ1 of 2 models qualify · AHRI 207641344 |
| Non-ducted, 2.5–3 tons | No models in this size class | 90.9(50 is the typical model of its size class)SENA-36HF-MOB3 of 9 models qualify · AHRI 213732656 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 76.2(50 is the typical model of its size class)SENA-48HF-MOB1 of 2 models qualify · AHRI 213732659 |
All-around best
| Size and duct type | BROCKAll-around score, best model | SenvilleAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 41.0(50 is the typical model of its size class)PH5SAN418**AA*with indoor coil CAP**2517AL and furnace PG80ESUA36040B1 of 1 models have all five ratings · AHRI 211276012 | 85.2(50 is the typical model of its size class) (higher)SENA/09HF/OQwith ducted air handler SENA/09HF/ID5 of 5 models have all five ratings · AHRI 207641345 |
| Ducted, 2 tons | 62.2(50 is the typical model of its size class)PH7TAN424**AA*with indoor coil CAP**3721AL and furnace PG80VTLB60090C3 of 3 models have all five ratings · AHRI 213169195 | 80.1(50 is the typical model of its size class) (higher)SENA/24HF/OQwith ducted air handler SENA/24HF/ID2 of 2 models have all five ratings · AHRI 207641348 |
| Ducted, 2.5–3 tons | 66.4(50 is the typical model of its size class)PH7TAN436**AA*with ducted air handler PF4TNBD60L5 of 7 models have all five ratings · AHRI 213925458 | 83.7(50 is the typical model of its size class) (higher)SENA-36HF-MOB5 of 5 models have all five ratings · AHRI 213732657 |
| Ducted, 3.5–4.5 tons | 72.2(50 is the typical model of its size class)PH7TAN448**AA*with ducted air handler PF4TNBD60L8 of 10 models have all five ratings · AHRI 213280649 | 82.0(50 is the typical model of its size class) (higher)SENA-48HF-MOB4 of 4 models have all five ratings · AHRI 213732660 |
| Ducted, 5 tons and up | 64.7(50 is the typical model of its size class)PH5SAN460**AA*with ducted air handler PF4TNBD60L1 of 3 models have all five ratings · AHRI 213280500 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 87.6(50 is the typical model of its size class)SENA/09HF/OQwith ductless indoor unit SENA/09HF/IQ10 of 10 models have all five ratings · AHRI 207571418 |
| Non-ducted, 2 tons | No models in this size class | 84.3(50 is the typical model of its size class)SENA/24HF/OQwith ductless indoor unit SENA/24HF/IQ2 of 2 models have all five ratings · AHRI 207657630 |
| Non-ducted, 2.5–3 tons | No models in this size class | 86.4(50 is the typical model of its size class)SENA-36HF-MOB7 of 9 models have all five ratings · AHRI 213732656 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 77.9(50 is the typical model of its size class)SENA-48HF-MOB2 of 2 models have all five ratings · AHRI 213732659 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BROCK | Senville |
|---|---|---|
| COP at 5°F | beats 90% · 2.34PH7TAN436**AA*Ducted, 2.5–3 tons | beats 91% · 2.21SENA/24HF/OQNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 35% · 60%PH5SAN436**AA*Ducted, 2.5–3 tons | beats 97% · 103%SENA-36HF-MOBNon-ducted, 2.5–3 tons |
| HSPF2 | beats 52% · 8.1PH5SAN460**AA*Ducted, 5 tons and up | beats 98% · 12.0SENA/09HF/OQDucted, up to 1.5 tons |
| SEER2 | beats 82% · 17.5PH7TAN448**AA*Ducted, 3.5–4.5 tons | beats 99% · 24.6SENA/30HF/MOQNon-ducted, 2.5–3 tons |
| EER2 | beats 98% · 13.0PH7TAN448**AA*Ducted, 3.5–4.5 tons | beats 98% · 16.2SENA/09HF/OQNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 39% · 30,200 Btu/hPH7TAN460**AA*Ducted, 3.5–4.5 tons | beats 96% · 20,000 Btu/hSENA-18HF-MOBNon-ducted, up to 1.5 tons |