Skip to content

BROCK vs Senville heat pumps

Measured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings. BROCK has 36 outdoor models, Senville has 34 outdoor models. BROCK has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BROCK and Senville on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Senville scores higher on 5 of the 6 ratings.
  • BROCK
  • Senville
  • Other ranked manufacturers
BROCKSenville

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBROCKSenville
Efficiency index35%median —64%median — · 2nd ranked
COP at 5°F41%median 1.8057%median 2.00 · 15th ranked
Capacity retention at 5°F13%median 41%68%median 91% · 1st ranked
HSPF224%median 6.772%median 10.0 · 2nd ranked
SEER224%median 13.468%median 21.1 · 1st ranked
EER264% (higher)median 11.161% (higher)median 12.0 · 5th ranked
Heating capacity at 5°F17%median 17,000 Btu/h66%median 21,200 Btu/h · 3rd ranked
Outdoor models3634
AHRI certifications3,77064

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBROCKSenville
CEE 2025 Tier 1 (Split ASHP)19.4%7 models82.4%28 models
CEE 2026 Tier 1 (Split ASHP)11.1%4 models79.4%27 models
CEE Advanced Tier (Split ASHP)0%0 models2.9%1 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models73.5%25 models
DOE Cold Climate Heat Pump Challenge0%0 models2.9%1 models
ENERGY STAR Cold Climate0%0 models70.6%24 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • BROCK
  • Senville
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBROCKSenville
Ducted, up to 1.5 tons2 · index 45%4 · index 77%
Ducted, 2 tons4 · index 35%4 · index 77%
Ducted, 2.5–3 tons11 · index 35%5 · index 69%
Ducted, 3.5–4.5 tons17 · index 31%6 · index 62%
Ducted, 5 tons and up2 · index 61%None
Non-ducted, up to 1.5 tonsNone15 · index 62%
Non-ducted, 2 tonsNone2 · index 55%
Non-ducted, 2.5–3 tonsNone5 · index 47%
Non-ducted, 3.5–4.5 tonsNone2 · index 67%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBROCKCold-climate score, best modelSenvilleCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)80.0(50 is the typical model of its size class)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models qualify · AHRI 215735300
Ducted, 2 tonsNone on this board (0 of 4 models qualify)85.7(50 is the typical model of its size class)SENA-24HF-OGwith ducted air handler SENA-24HF-IDG4 of 4 models qualify · AHRI 215735303
Ducted, 2.5–3 tonsNone on this board (0 of 11 models qualify)82.5(50 is the typical model of its size class)SENA-36HF-MOA4 of 5 models qualify · AHRI 215735318
Ducted, 3.5–4.5 tonsNone on this board (0 of 17 models qualify)82.7(50 is the typical model of its size class)SENA-48HF-MOA4 of 6 models qualify · AHRI 215735321
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class96.7(50 is the typical model of its size class)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG9 of 15 models qualify · AHRI 215735294
Non-ducted, 2 tonsNo models in this size class89.4(50 is the typical model of its size class)SENA-24HF-OGwith ductless indoor unit SENA-24HF-ICG2 of 2 models qualify · AHRI 215735307
Non-ducted, 2.5–3 tonsNo models in this size class78.0(50 is the typical model of its size class)SENA-36HF-MOA3 of 5 models qualify · AHRI 215735319
Non-ducted, 3.5–4.5 tonsNo models in this size class73.4(50 is the typical model of its size class)SENA-48HF-MOA2 of 2 models qualify · AHRI 215735322

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBROCKAll-around score, best modelSenvilleAll-around score, best model
Ducted, up to 1.5 tons48.3(50 is the typical model of its size class)PH5SAN519**AA*with indoor coil CAA**1917AM and furnace PG92MSAA42060B2 of 2 models have all five ratings · AHRI 21770247486.7(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models have all five ratings · AHRI 215735300
Ducted, 2 tons60.6(50 is the typical model of its size class)PH8TAN524**AA*with indoor coil CAA**3721AM and furnace PG80MSUA48060B4 of 4 models have all five ratings · AHRI 21564787689.9(50 is the typical model of its size class) (higher)SENE-24EL-OHwith ducted air handler SENE-24EL-IHH4 of 4 models have all five ratings · AHRI 218069801
Ducted, 2.5–3 tons66.7(50 is the typical model of its size class)PH8TAN536**AA*with ducted air handler PF5TNBD60L11 of 11 models have all five ratings · AHRI 21562894883.6(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735318
Ducted, 3.5–4.5 tons72.7(50 is the typical model of its size class)PH8TAN548**AA*with ducted air handler QFVA5D6021X16 of 16 models have all five ratings · AHRI 21869544483.9(50 is the typical model of its size class) (higher)SENA-48HF-MOA6 of 6 models have all five ratings · AHRI 215735321
Ducted, 5 tons and up80.2(50 is the typical model of its size class)PH8TAN560**AA*with ducted air handler PF5TNBD60L3 of 3 models have all five ratings · AHRI 215560743No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class96.2(50 is the typical model of its size class)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG13 of 15 models have all five ratings · AHRI 215735294
Non-ducted, 2 tonsNo models in this size class76.4(50 is the typical model of its size class)SENA-24HF-OGwith ductless indoor unit SENA-24HF-IGG2 of 2 models have all five ratings · AHRI 215735298
Non-ducted, 2.5–3 tonsNo models in this size class78.3(50 is the typical model of its size class)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735317
Non-ducted, 3.5–4.5 tonsNo models in this size class75.6(50 is the typical model of its size class)SENA-48HF-MOA2 of 2 models have all five ratings · AHRI 215735320

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBROCKSenville
COP at 5°Fbeats 92% · 2.48PH8TAN536**AA*Ducted, 2.5–3 tonsbeats 97% · 2.40SENA-06HF-OGNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 41% · 52%PH5SAN560**AA*Also listed as PH5SAP560**AADucted, 5 tons and upbeats 97% · 112%SENA-09HF-OGDucted, up to 1.5 tons
HSPF2beats 58% · 8.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 99% · 14.8SENA-06HF-OGNon-ducted, up to 1.5 tons
SEER2beats 81% · 17.5PH8TAN560**AA*Ducted, 5 tons and upbeats 100% · 25.0SENE-24EL-OHDucted, 2 tons
EER2beats 99% · 13.5PH8TAN548**AA*Ducted, 3.5–4.5 tonsbeats 99% · 18.0SENA-06HF-OGNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 44% · 8,600 Btu/hPH5SAN518**AA*Ducted, up to 1.5 tonsbeats 99% · 22,600 Btu/hSENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tons

More comparisons