Which heat pumps meet CEE, DOE cold-climate, Xcel and ENERGY STAR standards

Each standard is checked against AHRI-certified ratings, one certification at a time: a model qualifies when at least one of its indoor pairings meets every criterion of a path on its own. Values are never combined across pairings. Program rules beyond ratings are not checked.

New to heat pump ratings? The Simple view explains them in plain words →

StandardsData as of updated · sources

Qualification at a glance

Share of 12,326 outdoor models with at least one qualifying certification
StandardShare of modelsModelsCertifications
CEE 2025 Tier 1 (Split ASHP)Consortium for Energy Efficiency57.1%7,034217,596
CEE 2026 Tier 1 (Split ASHP)Consortium for Energy Efficiency55.6%6,849198,792
CEE Advanced Tier (Split ASHP)Consortium for Energy Efficiency2.6%3221,066
Xcel Energy Colorado cold-climate ASHP (2025)Xcel Energy52.8%6,511185,854
DOE Cold Climate Heat Pump ChallengeU.S. Department of Energy2.6%3221,066
ENERGY STAR Cold ClimateU.S. EPA41.7%5,143125,396

Download CSV of qualification by standard and peer groupEach standard for all models and for every size and duct type (this table and the heatmap below).

How models move through the tiers

Every model in one band, from its duct type to the highest CEE Tier 1 level it meets and whether it reaches the cold-climate tier.
From duct type to cold-climate tier12,326 outdoor models; each band is the models that share a path, each model in exactly one band57.1% of models meet CEE Tier 1 (2025) and 55.6% the stricter 2026 level, but only 2.6% (322) reach the cold-climate tier: full capacity and a COP of 2.1 at 5°F. 1 of those miss Tier 1 itself, on a cooling rating.
Duct typeCEE Tier 1CEE Advanced / DOE CCHP

Cold-climate tier = CEE Advanced, which uses the same rating criteria as the DOE Cold Climate Heat Pump Challenge (HSPF2 8.5, COP 2.1 at 5°F, 100% capacity at 5°F). It has no SEER2/EER2 path, so a model can reach it without meeting Tier 1.
Show the data as a table
Models per path
Duct typeHighest CEE Tier 1Cold-climate tierModels
DuctedCEE 2026Yes113
DuctedCEE 2026No1,862
DuctedCEE 2025 onlyNo116
DuctedBelow Tier 1Yes1
DuctedBelow Tier 1No3,968
Non-ductedCEE 2026Yes97
Non-ductedCEE 2026No2,668
Non-ductedCEE 2025 onlyNo54
Non-ductedBelow Tier 1No1,262
Ducted + ductless headsCEE 2026Yes111
Ducted + ductless headsCEE 2026No1,998
Ducted + ductless headsCEE 2025 onlyNo15
Ducted + ductless headsBelow Tier 1No61

Source: AHRI Directory, criteria from CEE and DOE · as of

Qualification by size and duct type

The same standard is easy for one kind of unit and hard for another. Each cell is the share of that peer group’s models that qualify (darker is more).
Share of each peer group’s models (by representative certification) with at least one qualifying certification
Size and duct typeCEE 2025CEE 2026CEE AdvancedXcel CCDOE CCHPENERGY STAR CC
Ducted, up to 1.5 tons1,827 models48%88648%8802%4557%1,0402%4551%926
Ducted, 2 tons1,152 models68%77966%7562%2161%7032%2149%566
Ducted, 2.5–3 tons2,198 models55%1,21551%1,1191%2246%1,0071%2237%818
Ducted, 3.5–4.5 tons2,607 models43%1,13443%1,1082%5040%1,0462%5036%941
Ducted, 5 tons and up458 models30%13730%1370%29%390%210%47
Non-ducted, up to 1.5 tons3,568 models76%2,71174%2,6574%13071%2,5214%13053%1,889
Non-ducted, 2 tons903 models78%70378%7022%1772%6532%1755%498
Non-ducted, 2.5–3 tons1,140 models80%91580%9104%4476%8704%4459%673
Non-ducted, 3.5–4.5 tons570 models81%46381%4601%587%4971%574%419
Non-ducted, 5 tons and up85 models89%7658%492%235%302%228%24

What keeps models out

For the models that miss a standard: whether a single rating is short (and which), a needed rating is not published, or several fall short. Judged on each model’s representative certification against the path it comes closest to.
  • Meets
  • One rating short
  • A needed rating is not published
  • Two or more short

The criteria

Minimum values. Ducted and non-ducted paths apply only to that equipment type.

CEE 2025 Tier 1 (Split ASHP)

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

CEE 2026 Tier 1 (Split ASHP)

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

CEE Advanced Tier (Split ASHP)

CEE’s cold-climate tier: full rated capacity and a COP of at least 2.1 at 5°F.

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Advanced≥ 8.5≥ 2.1≥ 100%

Xcel Energy Colorado cold-climate ASHP (2025)

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Not checked: Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.

DOE Cold Climate Heat Pump Challenge

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Not checked: Requirements not published in AHRI ratings (cut-in temperature, GWP, controls) are not checked.

ENERGY STAR Cold Climate

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.