Which heat pumps meet CEE, DOE cold-climate, Xcel and ENERGY STAR standards

Each standard is checked against AHRI-certified ratings, one certification at a time: a model qualifies when at least one of its indoor pairings meets every criterion of a path on its own. Values are never combined across pairings. Program rules beyond ratings are not checked.

Simple view, for homeowners: top picks by size and what each rating measures →

StandardsData as of updated · sources

Share of models that qualify

Share of 13,514 outdoor models with at least one qualifying certification
StandardShare of modelsModelsCertifications
CEE 2025 Tier 1 (Split ASHP)Consortium for Energy Efficiency57.3%7,738235,156
CEE 2026 Tier 1 (Split ASHP)Consortium for Energy Efficiency55.7%7,528215,589
CEE Advanced Tier (Split ASHP)Consortium for Energy Efficiency2.5%3361,107
Xcel Energy Colorado cold-climate ASHP (2025)Xcel Energy52.7%7,126195,370
DOE Cold Climate Heat Pump ChallengeU.S. Department of Energy2.5%3361,107
ENERGY STAR Cold ClimateU.S. EPA40.6%5,489134,768

Download CSV of qualification by standard and peer groupEach standard for all models and for every size and duct type (this table and the heatmap below).

How models move through the tiers

Every model in one band, from its duct type to the highest CEE Tier 1 level it meets and whether it reaches the cold-climate tier.
From duct type to cold-climate tier13,514 outdoor models; each band is the models that share a path, each model in exactly one band57.3% of models meet CEE Tier 1 (2025) and 55.7% the stricter 2026 level, but only 2.5% (336) reach the cold-climate tier: full capacity and a COP of 2.1 at 5°F.
Duct typeCEE Tier 1CEE Advanced / DOE CCHP

Cold-climate tier = CEE Advanced, which uses the same rating criteria as the DOE Cold Climate Heat Pump Challenge (HSPF2 8.5, COP 2.1 at 5°F, 100% capacity at 5°F). It has no SEER2/EER2 path, so a model can reach it without meeting Tier 1.
Show the data as a table
Models per path
Duct typeHighest CEE Tier 1Cold-climate tierModels
DuctedCEE 2026Yes115
DuctedCEE 2026No1,973
DuctedCEE 2025 onlyNo123
DuctedBelow Tier 1No4,160
Non-ductedCEE 2026Yes98
Non-ductedCEE 2026No3,105
Non-ductedCEE 2025 onlyNo72
Non-ductedBelow Tier 1No1,553
Ducted + ductless headsCEE 2026Yes123
Ducted + ductless headsCEE 2026No2,114
Ducted + ductless headsCEE 2025 onlyNo15
Ducted + ductless headsBelow Tier 1No63

Source: AHRI Directory, criteria from CEE and DOE · as of

Qualification by size and duct type

The same standard is easy for one kind of unit and hard for another. Each cell is the share of that peer group’s models that qualify (darker is more).
Share of each peer group’s models (by representative certification) with at least one qualifying certification
Size and duct typeCEE 2025CEE 2026CEE AdvancedXcel CCDOE CCHPENERGY STAR CC
Ducted, up to 1.5 tons1,963 models48%94948%9412%4657%1,1102%4650%974
Ducted, 2 tons1,208 models68%82266%7972%2162%7442%2148%585
Ducted, 2.5 to 3 tons2,337 models56%1,30952%1,2111%2447%1,0931%2438%883
Ducted, 3.5 to 4.5 tons2,700 models43%1,15942%1,1332%5339%1,0652%5335%949
Ducted, 5 tons and up475 models30%14430%1430%29%420%211%50
Non-ducted, up to 1.5 tons4,150 models75%3,09273%3,0213%13669%2,8643%13650%2,069
Non-ducted, 2 tons1,036 models76%79176%7892%1868%7072%1852%541
Non-ducted, 2.5 to 3 tons1,264 models78%99278%9874%4575%9444%4557%722
Non-ducted, 3.5 to 4.5 tons604 models82%49682%4931%587%5281%573%440
Non-ducted, 5 tons and up89 models90%8057%512%234%302%227%24

What keeps models out

For the models that miss a standard: whether a single rating is short (and which), a needed rating is not published, or several fall short. Judged on each model’s representative certification against the path it comes closest to.
  • Meets
  • One rating short
  • A needed rating is not published
  • Two or more short

The criteria

Minimum values. Ducted and non-ducted paths apply only to that equipment type.

CEE 2025 Tier 1 (Split ASHP)

The CEE 2025 Tier 1 efficiency level for split air-source heat pumps, used by many utility rebate programs.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 60%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 45%

CEE 2026 Tier 1 (Split ASHP)

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

CEE Advanced Tier (Split ASHP)

CEE’s cold-climate tier: full rated capacity and a COP of at least 2.1 at 5°F, with HSPF2 of at least 8.5.

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Advanced≥ 8.5≥ 2.1≥ 100%

Xcel Energy Colorado cold-climate ASHP (2025)

The efficiency thresholds Xcel Energy Colorado uses for its cold-climate air-source heat pump rebate.

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2COP@5°FCap. 5/47
DuctedDucted equipment only≥ 15.2≥ 10≥ 1.75≥ 70%
Non-ductedNon-ducted equipment only≥ 16≥ 9≥ 1.75≥ 70%

Program rules beyond ratings (installer enrollment, sizing, documentation) are not checked here.

DOE Cold Climate Heat Pump Challenge

Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.

A model qualifies when one certification meets every value in this row.
PathHSPF2COP@5°FCap. 5/47
Challenge specification≥ 8.5≥ 2.1≥ 100%

Requirements not published in AHRI ratings (cut-in temperature, GWP, controls) are not checked.

ENERGY STAR Cold Climate

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.