Skip to content

ENERGY STAR Cold Climate: 5,489 qualifying heat pumps

Units listed by ENERGY STAR with the cold-climate designation (matched to AHRI references).

Simple view, for homeowners: top picks by size and what each rating measures →

U.S. EPAData as of updated · sources

Share of models
40.3%
Qualifying models
5,489
Qualifying certifications
134,768
Paths
Listing

Criteria

No rating thresholds are applied here: a model counts when one of its AHRI certifications is matched to an ENERGY STAR record that carries the cold-climate designation.

Source: U.S. EPA

Qualification by size

Share of models meeting ENERGY STAR CC, by size
Show the data as a table
Share of models meeting ENERGY STAR CC, by size
GroupQualifying share
Up to 1.5 tons45% · 2,441 of 5,427
2 tons44.4% · 861 of 1,941
2.5 to 3 tons37.9% · 1,114 of 2,942
3.5 to 4.5 tons36.1% · 1,022 of 2,834
5 tons and up10.7% · 51 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted26.1%1,679 / 6,438
Non-ducted39.1%1,903 / 4,861
Ducted and non-ducted82.2%1,907 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree477 of 72965.4%
Midea355 of 55564%
Carrier232 of 84627.4%
Ephoca186 of 38248.7%
Innova186 of 38248.7%
BlueRidge125 of 19464.4%
TCL124 of 19264.6%
Rheem115 of 34633.2%
Mitsubishi Electric103 of 15666%
Lennox100 of 34129.3%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting ENERGY STAR Cold Climate, page 1 of 220
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1ACIQ-06ZPL-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD1HVAC0.5 tons6,000 Btu/h · Non-ducted2.40110%14.825.5CEE 25CEE 26CEE AdvXcelDOEES CC2216032267
2ACIQ-09Z-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-09W-HP230C1HVAC1 ton9,000 Btu/h · Non-ducted2.0770%9.121.2CEE 25CEE 26XcelES CC1216032261
3ACIQ-09ZPL-HP230C1HVAC · ACIQ Serieswith ducted air handler ACIQ-09CD-HH-MC1HVAC1 ton9,000 Btu/h · Ducted and non-ducted1.85120%13.820.5CEE 25CEE 26XcelES CC5216032278
4ACIQ-09ZS-HP115C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-09WS-HP115C1HVAC1 ton9,000 Btu/h · Non-ducted2.2173%10.724.5CEE 25CEE 26XcelES CC1216980879
5ACIQ-09ZS-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-09WS-HP230C1HVAC1 ton9,000 Btu/h · Non-ducted2.3382%13.024.6CEE 25CEE 26XcelES CC1216980881
6ACIQ-12-EHPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-12-AHD1HVAC1 ton12,000 Btu/h · Ducted2.0086%10.021.0CEE 25CEE 26XcelES CC1217110157
7ACIQ-12ZPL-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-12CC-HH-MC1HVAC1 ton12,000 Btu/h · Ducted and non-ducted1.9996%11.622.2CEE 25CEE 26XcelES CC4216032273
8ACIQ-12ZS-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-12WS-HP230C1HVAC1 ton12,000 Btu/h · Non-ducted2.3672%11.523.1CEE 25CEE 26XcelES CC1216980882
9ACIQ-18-HPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-18-PAH1HVAC1.5 tons18,000 Btu/h · Ducted2.12103%10.119.0CEE 25CEE 26CEE AdvXcelDOEES CC6216032234
10ACIQ-18Z-HH-M3C1HVAC · ACIQ Series1HVAC1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.0CEE 25CEE 26XcelES CC3216032295
11ACIQ-18ZPL-HP230C1HVAC · ACIQ Serieswith ducted air handler ACIQ-18CD-HH-MC1HVAC1.5 tons17,500 Btu/h · Ducted and non-ducted2.1092%11.118.4CEE 25CEE 26XcelES CC5216032280
12ACIQ-18ZS-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-18WS-HP230C1HVAC1.5 tons18,000 Btu/h · Non-ducted2.3572%11.124.0CEE 25CEE 26XcelES CC1216980883
13ACIQ-24-EHPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-24W-WMB1HVAC2 tons24,000 Btu/h · Ducted1.9678%10.417.4CEE 25CEE 26XcelES CC5216980818
14ACIQ-24-HP321HVAC · R32 Extreme Heat Unitarywith ducted air handler ACIQ-24-AH321HVAC2 tons24,000 Btu/h · Ducted2.00100%10.018.0CEE 25CEE 26XcelES CC1215387234
15ACIQ-24-HPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-24-PAH1HVAC2 tons24,000 Btu/h · Ducted2.1486%10.018.6CEE 25CEE 26XcelES CC6216032235
16ACIQ-24Z-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-24W-HP230C1HVAC2 tons24,000 Btu/h · Non-ducted2.1471%9.318.7CEE 25CEE 26XcelES CC1216032264
17ACIQ-24ZPL-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-24W-HH-MD1HVAC2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.0CEE 25CEE 26XcelES CC4216032271
18ACIQ-24ZS-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-24WS-HP230C1HVAC2 tons24,000 Btu/h · Non-ducted2.1571%10.023.5CEE 25CEE 26XcelES CC1216980884
19ACIQ-27Z-HH-M4C1HVAC · ACIQ Series1HVAC2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.0CEE 25CEE 26XcelES CC3216032298
20ACIQ-30-HPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-30W-WMB1HVAC2.5 tons30,000 Btu/h · Ducted2.00100%10.217.5CEE 25CEE 26XcelES CC7216980823
21ACIQ-36-EHPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-36-AHD1HVAC3 tons36,000 Btu/h · Ducted2.0075%8.716.1CEE 25CEE 26XcelES CC6216032224
22ACIQ-36-HP321HVAC · R32 Extreme Heat Unitarywith ducted air handler ACIQ-36-AH321HVAC3 tons34,000 Btu/h · Ducted2.0094%10.018.0CEE 25CEE 26XcelES CC1215387235
23ACIQ-36-HPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-36-AHD1HVAC3 tons36,000 Btu/h · Ducted1.90105%10.317.4CEE 25CEE 26XcelES CC7216032230
24ACIQ-36Z-HH-M5C1HVAC · ACIQ Series1HVAC3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.0CEE 25CEE 26XcelES CC3216032301
25ACIQ-36ZPL-HP230C1HVAC · ACIQ Serieswith ducted air handler ACIQ-36CD-HH-MC1HVAC3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.7CEE 25CEE 26XcelES CC3216032282

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter