Both views use the same certified data. This device remembers your choice.
Rheem heat pump efficiency: 346 outdoor models compared
Rheem has 346 heat pump outdoor models certified with this refrigerant group, in 26,750 AHRI-certified combinations. They are also sold as MAINLINE, Ruud, SURE, WEATHERKING. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Rheem makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 346
- AHRI certifications
- 26,750
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (308 models)
- Meet CEE 2025
- 36.4%
- 126 models
How Rheem compares with comparable models
- Rheem
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index308 models scored | 50% | 20th of 29 | — |
| COP at 5°F310 models scored | 59% | 11th of 29 | 2.06 |
| Capacity retention at 5°F309 models scored | 49% | 19th of 29 | 65% |
| HSPF2393 models scored | 44% | 21st of 29 | 7.5 |
| SEER2394 models scored | 42% | 24th of 29 | 15.2 |
| EER2394 models scored | 41% | 24th of 29 | 10.6 |
| Heating capacity at 5°F310 models scored | 49% | 19th of 29 | 19,650 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 36.4% | 126 |
| CEE 2026 Tier 1 (Split ASHP) | 34.7% | 120 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 6 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 34.4% | 119 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 6 |
| ENERGY STAR Cold Climate | 33.2% | 115 |
Sizes and duct types offered
- Rheem (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 33 | 56% | 75% | 49% | 54% |
| Ducted, 2 tons | 36 | 42% | 58% | 36% | 40% |
| Ducted, 2.5 to 3 tons | 91 | 46% | 60% | 38% | 36% |
| Ducted, 3.5 to 4.5 tons | 122 | 49% | 56% | 39% | 38% |
| Ducted, 5 tons and up | 32 | 45% | 35% | 44% | 38% |
| Non-ducted, up to 1.5 tons | 39 | 60% | 66% | 63% | 57% |
| Non-ducted, 2 tons | 9 | 55% | 66% | 57% | 46% |
| Non-ducted, 2.5 to 3 tons | 18 | 55% | 45% | 56% | 52% |
| Non-ducted, 3.5 to 4.5 tons | 12 | 49% | 48% | 54% | 43% |
| Non-ducted, 5 tons and up | 2 | 43% | 60% | 33% | 47% |
Every Rheem model in the market
- Rheem models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Rheem in the cold
- All listed models (median, middle 50% and 80%)
- Rheem (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 100% | 100% | 100% | 100% | 100% |
| Rheem, 17°F | 118 | 63% | 67% | 73% | 82% | 90% |
| Rheem, 5°F | 118 | 57% | 62% | 70% | 79% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 2.87 | 2.97 | 3.17 | 3.44 | 3.61 |
| Rheem, 17°F | 118 | 2.11 | 2.24 | 2.38 | 2.48 | 2.61 |
| Rheem, 5°F | 118 | 1.9 | 2 | 2 | 2.1 | 2.22 |
Source: NEEP ccASHP list · as of
Top Rheem models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1RD18AY48AJVCRHEEMwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZ | 3.5 tons39,000 Btu/h · Ducted | 125% | 2.80 | 10.0 | 50,000 | 17.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,052 | 218827549 | Ducted, 2.5 to 3 tons | 95.2 |
| 2ML06HP230NEXH-OMAINLINE · ML Serieswith ductless indoor unit ML06HP2301WYCAS-I | 0.5 tons6,500 Btu/h · Non-ducted | 109% | 2.40 | 12.0 | 8,100 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215864386 | Non-ducted, up to 1.5 tons | 94.9 |
| 3RD18AY36AJVCRHEEMwith ducted air handler L(E,G)M36FJ | 2.5 tons30,800 Btu/h · Ducted | 109% | 2.86 | 10.0 | 34,800 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,138 | 218029736 | Ducted, 2.5 to 3 tons | 94.3 |
| 4ML06HP230NEXH-OMAINLINE · ML Serieswith ducted air handler ML06HP230LSDUC-I | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26XcelES CC | 6 | 215864373 | Ducted, up to 1.5 tons | 93.7 |
| 5RD18AY24AJVCRHEEMwith indoor coil D(A,C,E)36A3J+TDR and furnace R951V0403A17UH | 1.5 tons20,200 Btu/h · Ducted | 116% | 2.60 | 10.0 | 23,600 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 554 | 218827453 | Ducted, up to 1.5 tons | 91.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ML06HP230NEXH-OMAINLINE · ML Serieswith ducted air handler ML06HP230LSDUC-I | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 6 | 215864373 | Ducted, up to 1.5 tons | 95.1 | 93.7 | 96.5 | 93.7 |
| 2ML06HP230NEXH-OMAINLINE · ML Serieswith ductless indoor unit ML06HP230NEX-I | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 25.3 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215864338 | Non-ducted, up to 1.5 tons | 94.5 | 94.5 | 94.4 | 94.9 |
| 3ML06HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML06HP230CALH-I | 0.5 tons6,000 Btu/h · Non-ducted | 150% | 2.00 | 15.6 | 35.0 | 17.4 | CEE 25CEE 26XcelES CC | 2 | 215864344 | Non-ducted, up to 1.5 tons | 93.6 | 88.0 | 99.3 | 88.0 |
| 4ML09HP230NEX-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230CON-I | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 12 | 215864361 | Non-ducted, up to 1.5 tons | 93.3 | 90.4 | 96.2 | 90.4 |
| 5ML09HP230CALH-OMAINLINE · ML Serieswith ductless indoor unit ML09HP230CALH-I | 1 ton9,000 Btu/h · Non-ducted | 113% | 2.00 | 14.6 | 33.3 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 215864345 | Non-ducted, up to 1.5 tons | 92.7 | 86.5 | 98.8 | 86.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | RP15AY48AJ2N | 3.08 | Ducted, 3.5 to 4.5 tons | 100% | 216438507 |
| Capacity retention at 5°F | ML06HP230CALH-O | 150% | Non-ducted, up to 1.5 tons | 100% | 215864344 |
| HSPF2 | ML06HP230CALH-O | 15.6 | Non-ducted, up to 1.5 tons | 100% | 215864344 |
| SEER2 | ML06HP230CALH-O | 35.0 | Non-ducted, up to 1.5 tons | 100% | 215864344 |
| EER2 | ML06HP230CALH-O | 17.4 | Non-ducted, up to 1.5 tons | 99% | 215864344 |
| Heating capacity at 5°F | RP15AY30AJ2N | 35,800 Btu/h | Ducted, 2 tons | 100% | 218426824 |
Rheem size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I20 of 33 models qualify · AHRI 215864373 | 95.1(50 is the typical model of its size class)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I33 of 33 models have all five ratings · AHRI 215864373 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)ML24HP230NEXH-Owith ducted air handler ML24HP230HSDUC-I17 of 35 models qualify · AHRI 215864380 | 78.9(50 is the typical model of its size class)ML24HP230NEX-Owith ducted air handler ML24HP230HSDUC-I33 of 33 models have all five ratings · AHRI 215864360 |
| Ducted, 2.5 to 3 tons | 94.3(50 is the typical model of its size class)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ29 of 91 models qualify · AHRI 218029736 | 92.7(50 is the typical model of its size class)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ69 of 92 models have all five ratings · AHRI 218029736 |
| Ducted, 3.5 to 4.5 tons | 95.2(50 is the typical model of its size class)RD18AY48AJVCwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZ35 of 123 models qualify · AHRI 218827549 | 86.4(50 is the typical model of its size class)RD18AY48AJVCwith ducted air handler L(E,G)M60IJ71 of 118 models have all five ratings · AHRI 218029742 |
| Ducted, 5 tons and up | 78.1(50 is the typical model of its size class)RP17AY60AJVCwith indoor coil RCFY6024STANM and furnace R801V1255A24UHNAlso sold as SURE SP17AY60AJVC2 of 32 models qualify · AHRI 218160560 | 70.6(50 is the typical model of its size class)RP17AY60AJVCwith ducted air handler RH2TY6024STANNAlso sold as SURE SP17AY60AJVC24 of 38 models have all five ratings · AHRI 218160613 |
| Non-ducted, up to 1.5 tons | 94.9(50 is the typical model of its size class)ML06HP230NEXH-Owith ductless indoor unit ML06HP2301WYCAS-I30 of 39 models qualify · AHRI 215864386 | 94.5(50 is the typical model of its size class)ML06HP230NEXH-Owith ductless indoor unit ML06HP230NEX-I38 of 39 models have all five ratings · AHRI 215864338 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)ML24HP230NEXH-Owith ductless indoor unit ML24HP230STDCAS-I9 of 9 models qualify · AHRI 215864372 | 78.3(50 is the typical model of its size class)ML24HP230CALH-Owith ductless indoor unit ML24HP230CALH-I8 of 8 models have all five ratings · AHRI 215864348 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)ML36HP230LCMH-Owith ductless indoor unit ML36HP230FLO-I15 of 18 models qualify · AHRI 215864403 | 78.8(50 is the typical model of its size class)ML36HP230MULH-O*Also listed as ML36HP230MULH - O18 of 19 models have all five ratings · AHRI 216623571 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)ML48HP230MULH-O*Also listed as ML48HP230MULH - O11 of 12 models qualify · AHRI 216623576 | 75.4(50 is the typical model of its size class)ML48HP230MULH-O*Also listed as ML48HP230MULH - O12 of 12 models have all five ratings · AHRI 216623574 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 59.0(50 is the typical model of its size class)ML55HP230MUL-O*2 of 2 models have all five ratings · AHRI 216623550 |
Newest Rheem certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| RP17AY48AJVCRUUD · Achiever Pluswith indoor coil RCFY4824STANM and furnace U98MV1155A24UPS | 3.5 tons44,500 Btu/h · Ducted | 2.00 | 83% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 308 | 219136725 |
| RP17AY36AJVCRUUD · Achiever Pluswith indoor coil RCFY3621STANM and furnace U98MV1005A21UPS | 3 tons34,200 Btu/h · Ducted | 2.00 | 91% | 9.5 | 17.0 | CEE 25CEE 26XcelES CC | 580 | 219136720 |
| RP17AY24AJVCRUUD · Achiever Pluswith indoor coil RCFY2417STANM and furnace U98MV0703A17UPS | 2 tons22,400 Btu/h · Ducted | 2.10 | 81% | 9.5 | 17.0 | CEE 25CEE 26XcelES CC | 244 | 219136714 |
| RD17AY60AJVCSURE · VANTIXwith ducted air handler SH2VY6024STACN | 4.5 tons56,000 Btu/h · Ducted | 2.20 | 82% | 9.5 | 17.0 | CEE 25CEE 26Xcel | 3 | 219125962 |
| RD17AY48AJVCSURE · VANTIXwith ducted air handler SH2VY4821STACN | 3.5 tons44,000 Btu/h · Ducted | 2.10 | 83% | 9.5 | 16.2 | None | 3 | 219125960 |
Compare Rheem
Rheem includes these brand names as listed in AHRI: MAINLINE, Rheem, Ruud, SURE, WEATHERKING. Standards are checked against published thresholds; program rules beyond ratings are not checked.