Skip to content

Innovair heat pump efficiency: 126 outdoor models compared

Innovair has 126 heat pump outdoor models certified with this refrigerant group, in 484 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Innovair makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
126
AHRI certifications
484
Efficiency index
58%
Typical model vs same-size, same-type peers (167 models)
Meet CEE 2025
82.5%
104 models

How Innovair compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Innovair against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Innovair’s own modelsInnovair is strongest on HSPF2 (its typical model beats 61% of comparable models) and weakest on EER2 (51%).
  • Innovair
  • Middle half of its models
  • Other ranked manufacturers
Innovair

Source: AHRI Directory, NEEP · as of

Average peer percentile of Innovair’s models
RatingBeats comparable modelsRankRaw median
Efficiency index167 models scored58%8th of 29—
COP at 5°F167 models scored58%12th of 292.00
Capacity retention at 5°F167 models scored60%7th of 2978%
HSPF2174 models scored61%8th of 299.5
SEER2174 models scored60%9th of 2920.0
EER2174 models scored51%16th of 2911.7
Heating capacity at 5°F167 models scored60%9th of 2919,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Innovair’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Innovair (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1970%69%68%71%
Ducted, 2 tons1159%69%54%60%
Ducted, 2.5–3 tons2662%56%66%67%
Ducted, 3.5–4.5 tons2364%60%71%65%
Ducted, 5 tons and up463%61%81%83%
Non-ducted, up to 1.5 tons4853%57%57%52%
Non-ducted, 2 tons952%59%54%46%
Non-ducted, 2.5–3 tons2054%51%53%56%
Non-ducted, 3.5–4.5 tons1252%44%59%53%
Non-ducted, 5 tons and up259%79%47%77%

Every Innovair model in the market

Innovair’s 174 models with a known size and duct type, over the shape of the whole catalog.
Innovair models by size and ratingColoured: Innovair · grey shapes: all 14,508 models · lines: catalog medians by size
  • Innovair models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 174 innovair models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Innovair models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Innovair cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1MOS06H2BH0AINNOVAIR · MHW Serieswith ductless indoor unit MHW06H2BHRB0.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.5CEE 25CEE 26CEE AdvXcelDOEES CC1215725442Non-ducted, up to 1.5 tons96.7
2MOS24H2BH0AINNOVAIR · MOS Serieswith ductless indoor unit MCS24H2BHRA2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC5217230001Non-ducted, 2 tons89.4
3MOS36H2BH0AINNOVAIR · MOS Serieswith ductless indoor unit MFC36H2BHRA3 tons36,400 Btu/h · Non-ducted104%2.0210.839,50020.0CEE 25CEE 26XcelES CC3217230015Non-ducted, 2.5–3 tons89.4
4SHV18H2BAINNOVAIR · SWV Serieswith ducted air handler SWV18BDA1.5 tons18,000 Btu/h · Ducted103%2.1010.819,60019.3CEE 25CEE 26CEE AdvXcelDOEES CC9216027612Ducted, up to 1.5 tons86.7
5MOS24H2BH0AINNOVAIR · MDH Serieswith ducted air handler MDH24H2MHWA2 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26XcelES CC5215725473Ducted, 2 tons85.7

All-around best

Top 5 Innovair models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1MOS06H2BH0AINNOVAIR · MHW Serieswith ductless indoor unit MHW06H2BHRB0.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.518.0CEE 25CEE 26CEE AdvXcelDOEES CC1215725442Non-ducted, up to 1.5 tons96.296.795.796.7
2MOS09H2BM0AINNOVAIR · MHW Serieswith ductless indoor unit MHW09H2BHRB1 ton9,000 Btu/h · Non-ducted80%2.3712.525.814.9CEE 25CEE 26XcelES CC5215725438Non-ducted, up to 1.5 tons88.384.492.384.4
3MOS24H2BM0AINNOVAIR · MHW Serieswith ductless indoor unit MHW24H2BHRB2 tons24,000 Btu/h · Non-ducted78%2.5411.723.014.0CEE 25CEE 26XcelES CC5215725441Non-ducted, 2 tons86.884.589.184.5
4MOS09H2BH0AINNOVAIR · MDL Serieswith ducted air handler MDL09H2MHWA1 ton9,000 Btu/h · Ducted112%1.8912.521.413.4CEE 25CEE 26XcelES CC5215725467Ducted, up to 1.5 tons86.780.093.580.0
5MOM48H2BM6AINNOVAIR · MOM SeriesAlso listed as MOM48H2BM6B4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26XcelES CC3215725499Ducted, 3.5–4.5 tons85.177.992.377.9

Best model on each rating

Innovair’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FMOM27H2XE3A2.80Non-ducted, 2.5–3 tons100%218731841
Capacity retention at 5°FQOS09H2BH0A133%Ducted, up to 1.5 tons100%216626158
HSPF2MOS06H2BH0A14.8Non-ducted, up to 1.5 tons99%215725442
SEER2POM27H2BM3A22.0Ducted, 2.5–3 tons99%217258419
EER2MOS06H2BH0A18.0Non-ducted, up to 1.5 tons99%215725442
Heating capacity at 5°FSHV18H2BA19,600 Btu/hDucted, up to 1.5 tons98%216027612

All 126 Innovair models in Explore

Innovair size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Innovair: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons86.7(50 is the typical model of its size class)SHV18H2BAwith ducted air handler SWV18BDA16 of 18 models qualify · AHRI 21602761286.7(50 is the typical model of its size class)MOS09H2BH0Awith ducted air handler MDL09H2MHWA17 of 18 models have all five ratings · AHRI 215725467
Ducted, 2 tons85.7(50 is the typical model of its size class)MOS24H2BH0Awith ducted air handler MDH24H2MHWA10 of 12 models qualify · AHRI 21572547379.6(50 is the typical model of its size class)GOV36H2BAwith ducted air handler GAV24B2A10 of 11 models have all five ratings · AHRI 215318726
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class)MOS36H2BH0Awith ducted air handler MDH36H2MHWA22 of 26 models qualify · AHRI 21573533583.6(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B25 of 27 models have all five ratings · AHRI 215725523
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B20 of 23 models qualify · AHRI 21572552685.1(50 is the typical model of its size class)MOM48H2BM6AAlso listed as MOM48H2BM6B20 of 23 models have all five ratings · AHRI 215725499
Ducted, 5 tons and up58.3(50 is the typical model of its size class)PXV60H2A1 of 4 models qualify · AHRI 21775379267.5(50 is the typical model of its size class)MOS60H2BM0Awith ducted air handler MDH60H2MHWA4 of 4 models have all five ratings · AHRI 215725466
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB38 of 48 models qualify · AHRI 21572544296.2(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB48 of 48 models have all five ratings · AHRI 215725442
Non-ducted, 2 tons89.4(50 is the typical model of its size class)MOS24H2BH0Awith ductless indoor unit MCS24H2BHRA9 of 9 models qualify · AHRI 21723000186.8(50 is the typical model of its size class)MOS24H2BM0Awith ductless indoor unit MHW24H2BHRB9 of 9 models have all five ratings · AHRI 215725441
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class)MOS36H2BH0Awith ductless indoor unit MFC36H2BHRA16 of 20 models qualify · AHRI 21723001578.3(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B20 of 20 models have all five ratings · AHRI 215725522
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B11 of 12 models qualify · AHRI 21572552775.6(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B12 of 12 models have all five ratings · AHRI 215725525
Non-ducted, 5 tons and upNone on this board (0 of 2 models qualify)58.6(50 is the typical model of its size class)MOM60H2BM6AAlso listed as MOM60H2BM6B2 of 2 models have all five ratings · AHRI 215835696

All-around board, every manufacturer

Newest Innovair certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Innovair outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
SOV24H2BAINNOVAIRwith ducted air handler DM24E3J+TDR2 tons23,000 Btu/h · Ducted2.7788%8.116.0CEE 25CEE 26XcelES CC19218808343
TOF60H2XAInnovairwith ducted air handler TAV60X2A4.5 tons55,000 Btu/h · Ducted——7.514.3None2218795587
MOS24H2XE5AINNOVAIR · MOS Seireswith ductless indoor unit MHW24H2XERA2 tons24,000 Btu/h · Non-ducted1.9771%9.519.0XcelES CC1218782135
MOS18H2XE5AINNOVAIRwith ductless indoor unit MHW18H2XERA1.5 tons17,000 Btu/h · Non-ducted1.9064%9.019.0CEE 251218782134
MOS12H2XE5AINNOVAIR · MOS Seireswith ductless indoor unit MHW12H2XERA1 ton12,000 Btu/h · Non-ducted1.9871%9.519.0XcelES CC1218782133

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Innovair

Manufacturers of a similar size, side by side.

Innovair includes these brand names as listed in AHRI: INNOVAIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.