Innovair heat pump efficiency: 126 outdoor models compared
Innovair has 126 heat pump outdoor models certified with this refrigerant group, in 484 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Innovair makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 126
- AHRI certifications
- 484
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (167 models)
- Meet CEE 2025
- 82.5%
- 104 models
How Innovair compares with comparable models
- Innovair
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index167 models scored | 58% | 8th of 29 | — |
| COP at 5°F167 models scored | 58% | 12th of 29 | 2.00 |
| Capacity retention at 5°F167 models scored | 60% | 7th of 29 | 78% |
| HSPF2174 models scored | 61% | 8th of 29 | 9.5 |
| SEER2174 models scored | 60% | 9th of 29 | 20.0 |
| EER2174 models scored | 51% | 16th of 29 | 11.7 |
| Heating capacity at 5°F167 models scored | 60% | 9th of 29 | 19,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 82.5% | 104 |
| CEE 2026 Tier 1 (Split ASHP) | 80.2% | 101 |
| CEE Advanced Tier (Split ASHP) | 1.6% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 78.6% | 99 |
| DOE Cold Climate Heat Pump Challenge | 1.6% | 2 |
| ENERGY STAR Cold Climate | 69% | 87 |
Sizes and duct types offered
- Innovair (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 19 | 70% | 69% | 68% | 71% |
| Ducted, 2 tons | 11 | 59% | 69% | 54% | 60% |
| Ducted, 2.5–3 tons | 26 | 62% | 56% | 66% | 67% |
| Ducted, 3.5–4.5 tons | 23 | 64% | 60% | 71% | 65% |
| Ducted, 5 tons and up | 4 | 63% | 61% | 81% | 83% |
| Non-ducted, up to 1.5 tons | 48 | 53% | 57% | 57% | 52% |
| Non-ducted, 2 tons | 9 | 52% | 59% | 54% | 46% |
| Non-ducted, 2.5–3 tons | 20 | 54% | 51% | 53% | 56% |
| Non-ducted, 3.5–4.5 tons | 12 | 52% | 44% | 59% | 53% |
| Non-ducted, 5 tons and up | 2 | 59% | 79% | 47% | 77% |
Every Innovair model in the market
- Innovair models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Innovair models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOS06H2BH0AINNOVAIR · MHW Serieswith ductless indoor unit MHW06H2BHRB | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215725442 | Non-ducted, up to 1.5 tons | 96.7 |
| 2MOS24H2BH0AINNOVAIR · MOS Serieswith ductless indoor unit MCS24H2BHRA | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 5 | 217230001 | Non-ducted, 2 tons | 89.4 |
| 3MOS36H2BH0AINNOVAIR · MOS Serieswith ductless indoor unit MFC36H2BHRA | 3 tons36,400 Btu/h · Non-ducted | 104% | 2.02 | 10.8 | 39,500 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217230015 | Non-ducted, 2.5–3 tons | 89.4 |
| 4SHV18H2BAINNOVAIR · SWV Serieswith ducted air handler SWV18BDA | 1.5 tons18,000 Btu/h · Ducted | 103% | 2.10 | 10.8 | 19,600 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 216027612 | Ducted, up to 1.5 tons | 86.7 |
| 5MOS24H2BH0AINNOVAIR · MDH Serieswith ducted air handler MDH24H2MHWA | 2 tons24,000 Btu/h · Ducted | 92% | 2.18 | 11.7 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 5 | 215725473 | Ducted, 2 tons | 85.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOS06H2BH0AINNOVAIR · MHW Serieswith ductless indoor unit MHW06H2BHRB | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215725442 | Non-ducted, up to 1.5 tons | 96.2 | 96.7 | 95.7 | 96.7 |
| 2MOS09H2BM0AINNOVAIR · MHW Serieswith ductless indoor unit MHW09H2BHRB | 1 ton9,000 Btu/h · Non-ducted | 80% | 2.37 | 12.5 | 25.8 | 14.9 | CEE 25CEE 26XcelES CC | 5 | 215725438 | Non-ducted, up to 1.5 tons | 88.3 | 84.4 | 92.3 | 84.4 |
| 3MOS24H2BM0AINNOVAIR · MHW Serieswith ductless indoor unit MHW24H2BHRB | 2 tons24,000 Btu/h · Non-ducted | 78% | 2.54 | 11.7 | 23.0 | 14.0 | CEE 25CEE 26XcelES CC | 5 | 215725441 | Non-ducted, 2 tons | 86.8 | 84.5 | 89.1 | 84.5 |
| 4MOS09H2BH0AINNOVAIR · MDL Serieswith ducted air handler MDL09H2MHWA | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26XcelES CC | 5 | 215725467 | Ducted, up to 1.5 tons | 86.7 | 80.0 | 93.5 | 80.0 |
| 5MOM48H2BM6AINNOVAIR · MOM SeriesAlso listed as MOM48H2BM6B | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 215725499 | Ducted, 3.5–4.5 tons | 85.1 | 77.9 | 92.3 | 77.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MOM27H2XE3A | 2.80 | Non-ducted, 2.5–3 tons | 100% | 218731841 |
| Capacity retention at 5°F | QOS09H2BH0A | 133% | Ducted, up to 1.5 tons | 100% | 216626158 |
| HSPF2 | MOS06H2BH0A | 14.8 | Non-ducted, up to 1.5 tons | 99% | 215725442 |
| SEER2 | POM27H2BM3A | 22.0 | Ducted, 2.5–3 tons | 99% | 217258419 |
| EER2 | MOS06H2BH0A | 18.0 | Non-ducted, up to 1.5 tons | 99% | 215725442 |
| Heating capacity at 5°F | SHV18H2BA | 19,600 Btu/h | Ducted, up to 1.5 tons | 98% | 216027612 |
Innovair size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.7(50 is the typical model of its size class)SHV18H2BAwith ducted air handler SWV18BDA16 of 18 models qualify · AHRI 216027612 | 86.7(50 is the typical model of its size class)MOS09H2BH0Awith ducted air handler MDL09H2MHWA17 of 18 models have all five ratings · AHRI 215725467 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)MOS24H2BH0Awith ducted air handler MDH24H2MHWA10 of 12 models qualify · AHRI 215725473 | 79.6(50 is the typical model of its size class)GOV36H2BAwith ducted air handler GAV24B2A10 of 11 models have all five ratings · AHRI 215318726 |
| Ducted, 2.5–3 tons | 83.2(50 is the typical model of its size class)MOS36H2BH0Awith ducted air handler MDH36H2MHWA22 of 26 models qualify · AHRI 215735335 | 83.6(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B25 of 27 models have all five ratings · AHRI 215725523 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B20 of 23 models qualify · AHRI 215725526 | 85.1(50 is the typical model of its size class)MOM48H2BM6AAlso listed as MOM48H2BM6B20 of 23 models have all five ratings · AHRI 215725499 |
| Ducted, 5 tons and up | 58.3(50 is the typical model of its size class)PXV60H2A1 of 4 models qualify · AHRI 217753792 | 67.5(50 is the typical model of its size class)MOS60H2BM0Awith ducted air handler MDH60H2MHWA4 of 4 models have all five ratings · AHRI 215725466 |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB38 of 48 models qualify · AHRI 215725442 | 96.2(50 is the typical model of its size class)MOS06H2BH0Awith ductless indoor unit MHW06H2BHRB48 of 48 models have all five ratings · AHRI 215725442 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)MOS24H2BH0Awith ductless indoor unit MCS24H2BHRA9 of 9 models qualify · AHRI 217230001 | 86.8(50 is the typical model of its size class)MOS24H2BM0Awith ductless indoor unit MHW24H2BHRB9 of 9 models have all five ratings · AHRI 215725441 |
| Non-ducted, 2.5–3 tons | 89.4(50 is the typical model of its size class)MOS36H2BH0Awith ductless indoor unit MFC36H2BHRA16 of 20 models qualify · AHRI 217230015 | 78.3(50 is the typical model of its size class)MOM36H2BH5AAlso listed as MOM36H2BH5B20 of 20 models have all five ratings · AHRI 215725522 |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B11 of 12 models qualify · AHRI 215725527 | 75.6(50 is the typical model of its size class)MOM48H2BH6AAlso listed as MOM48H2BH6B12 of 12 models have all five ratings · AHRI 215725525 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 58.6(50 is the typical model of its size class)MOM60H2BM6AAlso listed as MOM60H2BM6B2 of 2 models have all five ratings · AHRI 215835696 |
Newest Innovair certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SOV24H2BAINNOVAIRwith ducted air handler DM24E3J+TDR | 2 tons23,000 Btu/h · Ducted | 2.77 | 88% | 8.1 | 16.0 | CEE 25CEE 26XcelES CC | 19 | 218808343 |
| TOF60H2XAInnovairwith ducted air handler TAV60X2A | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 2 | 218795587 |
| MOS24H2XE5AINNOVAIR · MOS Seireswith ductless indoor unit MHW24H2XERA | 2 tons24,000 Btu/h · Non-ducted | 1.97 | 71% | 9.5 | 19.0 | XcelES CC | 1 | 218782135 |
| MOS18H2XE5AINNOVAIRwith ductless indoor unit MHW18H2XERA | 1.5 tons17,000 Btu/h · Non-ducted | 1.90 | 64% | 9.0 | 19.0 | CEE 25 | 1 | 218782134 |
| MOS12H2XE5AINNOVAIR · MOS Seireswith ductless indoor unit MHW12H2XERA | 1 ton12,000 Btu/h · Non-ducted | 1.98 | 71% | 9.5 | 19.0 | XcelES CC | 1 | 218782133 |
Compare Innovair
Innovair includes these brand names as listed in AHRI: INNOVAIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.