- Insights
- Manufacturers
- Mitsutomo
Both views use the same certified data. This device remembers your choice.
Mitsutomo heat pump efficiency: 57 outdoor models compared
Mitsutomo has 57 heat pump outdoor models certified with this refrigerant group, in 166 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Mitsutomo makes. Mitsutomo has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 57
- AHRI certifications
- 166
- Efficiency index
- 59%
- Typical model vs same-size, same-type peers (85 models)
- Meet CEE 2025
- 82.5%
- 47 models
How Mitsutomo compares with comparable models
- Mitsutomo
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index85 models scored | 59% | Not ranked | — |
| COP at 5°F85 models scored | 61% | Not ranked | 2.00 |
| Capacity retention at 5°F85 models scored | 59% | Not ranked | 79% |
| HSPF285 models scored | 70% | Not ranked | 9.7 |
| SEER285 models scored | 57% | Not ranked | 19.0 |
| EER285 models scored | 52% | Not ranked | 11.7 |
| Heating capacity at 5°F85 models scored | 63% | Not ranked | 21,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 82.5% | 47 |
| CEE 2026 Tier 1 (Split ASHP) | 78.9% | 45 |
| CEE Advanced Tier (Split ASHP) | 3.5% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75.4% | 43 |
| DOE Cold Climate Heat Pump Challenge | 3.5% | 2 |
| ENERGY STAR Cold Climate | 77.2% | 44 |
Sizes and duct types offered
- Mitsutomo (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 77% | 77% | 84% | 79% |
| Ducted, 2 tons | 5 | 69% | 62% | 82% | 75% |
| Ducted, 2.5 to 3 tons | 14 | 62% | 58% | 76% | 63% |
| Ducted, 3.5 to 4.5 tons | 12 | 66% | 48% | 82% | 69% |
| Ducted, 5 tons and up | 2 | 65% | 79% | 88% | 82% |
| Non-ducted, up to 1.5 tons | 19 | 53% | 67% | 59% | 50% |
| Non-ducted, 2 tons | 5 | 50% | 73% | 53% | 43% |
| Non-ducted, 2.5 to 3 tons | 9 | 50% | 46% | 65% | 42% |
| Non-ducted, 3.5 to 4.5 tons | 7 | 42% | 52% | 56% | 29% |
| Non-ducted, 5 tons and up | 1 | 27% | 41% | 18% | 16% |
Every Mitsutomo model in the market
- Mitsutomo models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Mitsutomo in the cold
- All listed models (median, middle 50% and 80%)
- Mitsutomo (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsutomo, 47°F | 57 | 100% | 100% | 100% | 100% | 100% |
| Mitsutomo, 17°F | 57 | 63% | 67% | 72% | 80% | 85% |
| Mitsutomo, 5°F | 57 | 56% | 62% | 69% | 80% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Mitsutomo, 47°F | 57 | 2.86 | 3.09 | 3.23 | 3.46 | 3.61 |
| Mitsutomo, 17°F | 57 | 2.07 | 2.19 | 2.3 | 2.45 | 2.6 |
| Mitsutomo, 5°F | 57 | 1.85 | 1.97 | 2 | 2.12 | 2.26 |
Source: NEEP ccASHP list · as of
Top Mitsutomo models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HO-SZ06-LA-QMitsutomo · HO Serieswith ductless indoor unit HJ-UZ06-LA-Q | 0.5 tons6,500 Btu/h · Non-ducted | 109% | 2.40 | 12.0 | 8,100 | 22.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217162582 | Non-ducted, up to 1.5 tons | 94.9 |
| 2HO-SZ06-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ06-LA-Q | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26XcelES CC | 3 | 217162571 | Ducted, up to 1.5 tons | 93.7 |
| 3RU-SZ09-LA-QMitsutomo · RU Serieswith ductless indoor unit HL-UZ09-LA-Q | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 8,600 | 26.0 | CEE 25CEE 26XcelES CC | 6 | 217162559 | Non-ducted, up to 1.5 tons | 90.4 |
| 4HO-SZ24-LA-QMitsutomo · HO Serieswith ductless indoor unit HC-UZ24-LA-Q | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 5 | 217162570 | Non-ducted, 2 tons | 90.1 |
| 5HO-SG36-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG36-LA-Q | 3 tons36,400 Btu/h · Non-ducted | 104% | 2.02 | 10.8 | 39,500 | 20.0 | CEE 25CEE 26XcelES CC | 4 | 217162601 | Non-ducted, 2.5 to 3 tons | 89.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HO-SZ06-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ06-LA-Q | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 3 | 217162571 | Ducted, up to 1.5 tons | 95.1 | 93.7 | 96.5 | 93.7 |
| 2HO-SZ06-LA-QMitsutomo · HO Serieswith ductless indoor unit HW-UZ06-LA-Q | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.29 | 14.6 | 25.3 | 16.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217162538 | Non-ducted, up to 1.5 tons | 94.5 | 94.5 | 94.4 | 94.9 |
| 3RU-SZ09-LA-QMitsutomo · RU Serieswith ductless indoor unit HL-UZ09-LA-Q | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 6 | 217162559 | Non-ducted, up to 1.5 tons | 93.3 | 90.4 | 96.2 | 90.4 |
| 4HO-SZ09-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ09-LA-Q | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26XcelES CC | 6 | 217162572 | Ducted, up to 1.5 tons | 87.1 | 80.6 | 93.6 | 80.6 |
| 5RO-MS48-LA-QMitsutomo · RO Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217162504 | Ducted, 3.5 to 4.5 tons | 85.3 | 78.1 | 92.6 | 78.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | RU-SZ12-LA-Q | 2.51 | Non-ducted, up to 1.5 tons | 99% | 217162560 |
| Capacity retention at 5°F | HO-SZ09-LA-Q | 126% | Non-ducted, up to 1.5 tons | 98% | 217162579 |
| HSPF2 | HO-MS48-LA-Q | 11.0 | Ducted, 3.5 to 4.5 tons | 99% | 217162519 |
| SEER2 | RO-MS48-LA-Q | 20.4 | Ducted, 3.5 to 4.5 tons | 96% | 217162504 |
| EER2 | HO-SZ06-LA-Q | 14.4 | Ducted, up to 1.5 tons | 99% | 217162571 |
| Heating capacity at 5°F | HO-SG36-LA-Q | 39,500 Btu/h | Non-ducted, 2.5 to 3 tons | 98% | 217162601 |
Mitsutomo size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q10 of 11 models qualify · AHRI 217162571 | 95.1(50 is the typical model of its size class)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q11 of 11 models have all five ratings · AHRI 217162571 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)HO-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models qualify · AHRI 217162578 | 78.9(50 is the typical model of its size class)RU-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models have all five ratings · AHRI 217162558 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)HO-SG36-LA-Qwith ducted air handler HD-UG36LA-Q10 of 14 models qualify · AHRI 217162598 | 83.9(50 is the typical model of its size class)HO-MP36-LA-Q14 of 14 models have all five ratings · AHRI 217162516 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)HO-MS48-LA-Q12 of 12 models qualify · AHRI 217162519 | 85.3(50 is the typical model of its size class)RO-MS48-LA-Q12 of 12 models have all five ratings · AHRI 217162504 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 65.9(50 is the typical model of its size class)RU-SG60-LA-Qwith ducted air handler HD-UG60AL-Q2 of 2 models have all five ratings · AHRI 217162592 |
| Non-ducted, up to 1.5 tons | 94.9(50 is the typical model of its size class)HO-SZ06-LA-Qwith ductless indoor unit HJ-UZ06-LA-Q12 of 19 models qualify · AHRI 217162582 | 94.5(50 is the typical model of its size class)HO-SZ06-LA-Qwith ductless indoor unit HW-UZ06-LA-Q19 of 19 models have all five ratings · AHRI 217162538 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)HO-SZ24-LA-Qwith ductless indoor unit HC-UZ24-LA-Q5 of 5 models qualify · AHRI 217162570 | 75.9(50 is the typical model of its size class)RU-SZ24-LA-Qwith ductless indoor unit HW-UZ24-LA-Q5 of 5 models have all five ratings · AHRI 217162547 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q7 of 9 models qualify · AHRI 217162601 | 67.1(50 is the typical model of its size class)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q9 of 9 models have all five ratings · AHRI 217162601 |
| Non-ducted, 3.5 to 4.5 tons | 70.3(50 is the typical model of its size class)HO-MS60-LA-Q6 of 7 models qualify · AHRI 217162523 | 62.6(50 is the typical model of its size class)HO-MS60-LA-Q7 of 7 models have all five ratings · AHRI 217162521 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 32.9(50 is the typical model of its size class)RO-MS60-LA-Q1 of 1 models have all five ratings · AHRI 217162506 |
Newest Mitsutomo certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| HO-SZ36-LC-QMitsutomo · HO Serieswith ductless indoor unit HW-UZ36-LC-Q | 3 tons33,000 Btu/h · Non-ducted | 1.91 | 96% | 10.5 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218072614 |
| HO-SG60-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG60-LA-Q | 4.5 tons54,000 Btu/h · Ducted and non-ducted | 1.91 | 90% | 10.7 | 18.0 | XcelES CC | 3 | 217162603 |
| HO-SG48-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG48-LA-Q | 4 tons48,000 Btu/h · Ducted and non-ducted | 1.83 | 90% | 10.1 | 18.5 | CEE 25CEE 26XcelES CC | 4 | 217162602 |
| HO-SG36-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG36-LA-Q | 3 tons36,400 Btu/h · Ducted and non-ducted | 2.02 | 104% | 10.8 | 20.0 | CEE 25CEE 26XcelES CC | 4 | 217162601 |
| RU-SG60-LA-QMitsutomowith ductless indoor unit HF-UG60-LA-Q | 4.5 tons54,000 Btu/h · Ducted and non-ducted | 2.01 | 58% | 9.5 | 19.5 | CEE 25CEE 26 | 3 | 217162595 |
Compare Mitsutomo
Mitsutomo includes these brand names as listed in AHRI: Mitsutomo. Standards are checked against published thresholds; program rules beyond ratings are not checked.