Skip to content

Mitsutomo heat pump efficiency: 57 outdoor models compared

Mitsutomo has 57 heat pump outdoor models certified with this refrigerant group, in 166 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Mitsutomo makes. Mitsutomo has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
57
AHRI certifications
166
Efficiency index
59%
Typical model vs same-size, same-type peers (85 models)
Meet CEE 2025
82.5%
47 models

How Mitsutomo compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Mitsutomo against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Mitsutomo’s own modelsMitsutomo is strongest on HSPF2 (its typical model beats 70% of comparable models) and weakest on EER2 (52%).
  • Mitsutomo
  • Middle half of its models
  • Other ranked manufacturers
Mitsutomo

Source: AHRI Directory, NEEP · as of

Average peer percentile of Mitsutomo’s models
RatingBeats comparable modelsRankRaw median
Efficiency index85 models scored59%Not ranked—
COP at 5°F85 models scored61%Not ranked2.00
Capacity retention at 5°F85 models scored59%Not ranked79%
HSPF285 models scored70%Not ranked9.7
SEER285 models scored57%Not ranked19.0
EER285 models scored52%Not ranked11.7
Heating capacity at 5°F85 models scored63%Not ranked21,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Mitsutomo’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Mitsutomo (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1177%77%84%79%
Ducted, 2 tons569%62%82%75%
Ducted, 2.5 to 3 tons1462%58%76%63%
Ducted, 3.5 to 4.5 tons1266%48%82%69%
Ducted, 5 tons and up265%79%88%82%
Non-ducted, up to 1.5 tons1953%67%59%50%
Non-ducted, 2 tons550%73%53%43%
Non-ducted, 2.5 to 3 tons950%46%65%42%
Non-ducted, 3.5 to 4.5 tons742%52%56%29%
Non-ducted, 5 tons and up127%41%18%16%

Every Mitsutomo model in the market

Mitsutomo’s 85 models with a known size and duct type, over the shape of the whole catalog.
Mitsutomo models by size and ratingColoured: Mitsutomo · grey shapes: all 15,936 models · lines: catalog medians by size
  • Mitsutomo models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 85 mitsutomo models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Mitsutomo in the cold

From NEEP’s cold-climate listings: 57 Mitsutomo models against all 6,343 listed models.
Mitsutomo capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical Mitsutomo model keeps 69% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • Mitsutomo (median, middle 50%)
Heating capacity, % of its 47°F maximum69%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Mitsutomo: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F57100%100%100%100%100%
Mitsutomo, 17°F5763%67%72%80%85%
Mitsutomo, 5°F5756%62%69%80%85%
Mitsutomo: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F572.863.093.233.463.61
Mitsutomo, 17°F572.072.192.32.452.6
Mitsutomo, 5°F571.851.9722.122.26

Source: NEEP ccASHP list · as of

Top Mitsutomo models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Mitsutomo cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1HO-SZ06-LA-QMitsutomo · HO Serieswith ductless indoor unit HJ-UZ06-LA-Q0.5 tons6,500 Btu/h · Non-ducted109%2.4012.08,10022.0CEE 25CEE 26CEE AdvXcelDOEES CC3217162582Non-ducted, up to 1.5 tons94.9
2HO-SZ06-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ06-LA-Q0.5 tons6,500 Btu/h · Ducted98%2.4113.87,80021.4CEE 25CEE 26XcelES CC3217162571Ducted, up to 1.5 tons93.7
3RU-SZ09-LA-QMitsutomo · RU Serieswith ductless indoor unit HL-UZ09-LA-Q1 ton9,000 Btu/h · Non-ducted96%2.2713.98,60026.0CEE 25CEE 26XcelES CC6217162559Non-ducted, up to 1.5 tons90.4
4HO-SZ24-LA-QMitsutomo · HO Serieswith ductless indoor unit HC-UZ24-LA-Q2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC5217162570Non-ducted, 2 tons90.1
5HO-SG36-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG36-LA-Q3 tons36,400 Btu/h · Non-ducted104%2.0210.839,50020.0CEE 25CEE 26XcelES CC4217162601Non-ducted, 2.5 to 3 tons89.4

All-around best

Top 5 Mitsutomo models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1HO-SZ06-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ06-LA-Q0.5 tons6,500 Btu/h · Ducted98%2.4113.821.414.4CEE 25CEE 26XcelES CC3217162571Ducted, up to 1.5 tons95.193.796.593.7
2HO-SZ06-LA-QMitsutomo · HO Serieswith ductless indoor unit HW-UZ06-LA-Q0.5 tons6,000 Btu/h · Non-ducted107%2.2914.625.316.0CEE 25CEE 26CEE AdvXcelDOEES CC3217162538Non-ducted, up to 1.5 tons94.594.594.494.9
3RU-SZ09-LA-QMitsutomo · RU Serieswith ductless indoor unit HL-UZ09-LA-Q1 ton9,000 Btu/h · Non-ducted96%2.2713.926.016.2CEE 25CEE 26XcelES CC6217162559Non-ducted, up to 1.5 tons93.390.496.290.4
4HO-SZ09-LA-QMitsutomo · HO Serieswith ducted air handler HD-UZ09-LA-Q1 ton9,000 Btu/h · Ducted112%1.8912.521.413.4CEE 25CEE 26XcelES CC6217162572Ducted, up to 1.5 tons87.180.693.680.6
5RO-MS48-LA-QMitsutomo · RO Series4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26XcelES CC3217162504Ducted, 3.5 to 4.5 tons85.378.192.678.1

Best model on each rating

Mitsutomo’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FRU-SZ12-LA-Q2.51Non-ducted, up to 1.5 tons99%217162560
Capacity retention at 5°FHO-SZ09-LA-Q126%Non-ducted, up to 1.5 tons98%217162579
HSPF2HO-MS48-LA-Q11.0Ducted, 3.5 to 4.5 tons99%217162519
SEER2RO-MS48-LA-Q20.4Ducted, 3.5 to 4.5 tons96%217162504
EER2HO-SZ06-LA-Q14.4Ducted, up to 1.5 tons99%217162571
Heating capacity at 5°FHO-SG36-LA-Q39,500 Btu/hNon-ducted, 2.5 to 3 tons98%217162601

All 57 Mitsutomo models in Explore

Mitsutomo size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Mitsutomo: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q10 of 11 models qualify · AHRI 21716257195.1(50 is the typical model of its size class)HO-SZ06-LA-Qwith ducted air handler HD-UZ06-LA-Q11 of 11 models have all five ratings · AHRI 217162571
Ducted, 2 tons85.8(50 is the typical model of its size class)HO-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models qualify · AHRI 21716257878.9(50 is the typical model of its size class)RU-SZ24-LA-Qwith ducted air handler HD-UZ24LA-Q5 of 5 models have all five ratings · AHRI 217162558
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class)HO-SG36-LA-Qwith ducted air handler HD-UG36LA-Q10 of 14 models qualify · AHRI 21716259883.9(50 is the typical model of its size class)HO-MP36-LA-Q14 of 14 models have all five ratings · AHRI 217162516
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)HO-MS48-LA-Q12 of 12 models qualify · AHRI 21716251985.3(50 is the typical model of its size class)RO-MS48-LA-Q12 of 12 models have all five ratings · AHRI 217162504
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)65.9(50 is the typical model of its size class)RU-SG60-LA-Qwith ducted air handler HD-UG60AL-Q2 of 2 models have all five ratings · AHRI 217162592
Non-ducted, up to 1.5 tons94.9(50 is the typical model of its size class)HO-SZ06-LA-Qwith ductless indoor unit HJ-UZ06-LA-Q12 of 19 models qualify · AHRI 21716258294.5(50 is the typical model of its size class)HO-SZ06-LA-Qwith ductless indoor unit HW-UZ06-LA-Q19 of 19 models have all five ratings · AHRI 217162538
Non-ducted, 2 tons90.1(50 is the typical model of its size class)HO-SZ24-LA-Qwith ductless indoor unit HC-UZ24-LA-Q5 of 5 models qualify · AHRI 21716257075.9(50 is the typical model of its size class)RU-SZ24-LA-Qwith ductless indoor unit HW-UZ24-LA-Q5 of 5 models have all five ratings · AHRI 217162547
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q7 of 9 models qualify · AHRI 21716260167.1(50 is the typical model of its size class)HO-SG36-LA-Qwith ductless indoor unit HF-UG36-LA-Q9 of 9 models have all five ratings · AHRI 217162601
Non-ducted, 3.5 to 4.5 tons70.3(50 is the typical model of its size class)HO-MS60-LA-Q6 of 7 models qualify · AHRI 21716252362.6(50 is the typical model of its size class)HO-MS60-LA-Q7 of 7 models have all five ratings · AHRI 217162521
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)32.9(50 is the typical model of its size class)RO-MS60-LA-Q1 of 1 models have all five ratings · AHRI 217162506

All-around board, every manufacturer

Newest Mitsutomo certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Mitsutomo outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
HO-SZ36-LC-QMitsutomo · HO Serieswith ductless indoor unit HW-UZ36-LC-Q3 tons33,000 Btu/h · Non-ducted1.9196%10.520.0CEE 25CEE 26XcelES CC1218072614
HO-SG60-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG60-LA-Q4.5 tons54,000 Btu/h · Ducted and non-ducted1.9190%10.718.0XcelES CC3217162603
HO-SG48-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG48-LA-Q4 tons48,000 Btu/h · Ducted and non-ducted1.8390%10.118.5CEE 25CEE 26XcelES CC4217162602
HO-SG36-LA-QMitsutomo · HO Serieswith ductless indoor unit HF-UG36-LA-Q3 tons36,400 Btu/h · Ducted and non-ducted2.02104%10.820.0CEE 25CEE 26XcelES CC4217162601
RU-SG60-LA-QMitsutomowith ductless indoor unit HF-UG60-LA-Q4.5 tons54,000 Btu/h · Ducted and non-ducted2.0158%9.519.5CEE 25CEE 263217162595

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Mitsutomo

Manufacturers of a similar size, side by side.

Mitsutomo includes these brand names as listed in AHRI: Mitsutomo. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter