- Insights
- Manufacturers
- Cooper&Hunter
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Cooper&Hunter heat pump efficiency: 63 outdoor models compared
Cooper&Hunter has 63 heat pump outdoor models certified with this refrigerant group, in 260 AHRI-certified combinations. They are also sold as C&H. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Cooper&Hunter makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 63
- AHRI certifications
- 260
- Efficiency index
- 64%
- Typical model vs same-size, same-type peers (100 models)
- Meet CEE 2025
- 85.7%
- 54 models
How Cooper&Hunter compares with comparable models
- Cooper&Hunter
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index100 models scored | 64% | 1st of 29 | — |
| COP at 5°F100 models scored | 65% | 3rd of 29 | 2.10 |
| Capacity retention at 5°F100 models scored | 62% | 5th of 29 | 80% |
| HSPF2100 models scored | 73% | 1st of 29 | 10.2 |
| SEER2100 models scored | 65% | 2nd of 29 | 21.0 |
| EER2100 models scored | 58% | 9th of 29 | 12.0 |
| Heating capacity at 5°F100 models scored | 65% | 5th of 29 | 24,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7% | 54 |
| CEE 2026 Tier 1 (Split ASHP) | 84.1% | 53 |
| CEE Advanced Tier (Split ASHP) | 7.9% | 5 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 73% | 46 |
| DOE Cold Climate Heat Pump Challenge | 7.9% | 5 |
| ENERGY STAR Cold Climate | 71.4% | 45 |
Sizes and duct types offered
- Cooper&Hunter (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 12 | 74% | 74% | 78% | 75% |
| Ducted, 2 tons | 6 | 62% | 59% | 71% | 70% |
| Ducted, 2.5–3 tons | 15 | 67% | 64% | 81% | 68% |
| Ducted, 3.5–4.5 tons | 14 | 67% | 54% | 83% | 73% |
| Ducted, 5 tons and up | 3 | 66% | 74% | 91% | 81% |
| Non-ducted, up to 1.5 tons | 20 | 65% | 70% | 69% | 67% |
| Non-ducted, 2 tons | 4 | 60% | 89% | 61% | 41% |
| Non-ducted, 2.5–3 tons | 13 | 62% | 67% | 65% | 60% |
| Non-ducted, 3.5–4.5 tons | 11 | 50% | 50% | 63% | 46% |
| Non-ducted, 5 tons and up | 2 | 71% | 88% | 73% | 69% |
Every Cooper&Hunter model in the market
- Cooper&Hunter models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Cooper&Hunter models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CHV6-RS60URBMHHCooper & Hunter | 5 tons60,000 Btu/h · Non-ducted | 100% | 2.30 | 11.0 | 63,000 | 21.5 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026559 | Non-ducted, 5 tons and up | 98.2 |
| 2CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 215864172 | Non-ducted, up to 1.5 tons | 96.7 |
| 3CHV6-RS48URBMHHCooper & Hunter | 4 tons48,000 Btu/h · Non-ducted | 100% | 2.40 | 10.8 | 54,000 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026556 | Non-ducted, 3.5–4.5 tons | 94.6 |
| 4CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MS | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26XcelES CC | 7 | 215864212 | Ducted, up to 1.5 tons | 93.5 |
| 5CHV6-RS36URBMHHCooper & Hunter | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.45 | 10.8 | 42,000 | 23.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026553 | Non-ducted, 2.5–3 tons | 92.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 215864172 | Non-ducted, up to 1.5 tons | 96.2 | 96.7 | 95.7 | 96.7 |
| 2CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MS | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 7 | 215864212 | Ducted, up to 1.5 tons | 95.0 | 93.5 | 96.5 | 93.5 |
| 3CH-RES09-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH09MMC | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 10 | 215864235 | Non-ducted, up to 1.5 tons | 92.6 | 89.5 | 95.7 | 89.5 |
| 4CH-RES24-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO24MASTWM-230VI | 2 tons24,000 Btu/h · Non-ducted | 78% | 2.54 | 11.7 | 23.0 | 14.0 | CEE 25CEE 26XcelES CC | 9 | 215864171 | Non-ducted, 2 tons | 86.8 | 84.5 | 89.1 | 84.5 |
| 5CH-RHP09-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS09MDT-MS | 1 ton9,000 Btu/h · Ducted | 112% | 1.89 | 12.5 | 21.4 | 13.4 | CEE 25CEE 26XcelES CC | 10 | 215864213 | Ducted, up to 1.5 tons | 86.7 | 80.0 | 93.5 | 80.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CHV6-RS48URBMHH | 2.40 | Non-ducted, 3.5–4.5 tons | 99% | 217026556 |
| Capacity retention at 5°F | CHV6-RS60URBMHH | 100% | Ducted, 5 tons and up | 100% | 217026558 |
| HSPF2 | CH-RHP06F9-230VO | 14.8 | Non-ducted, up to 1.5 tons | 99% | 215864172 |
| SEER2 | CH-R28MES-230VO | 25.0 | Non-ducted, 2.5–3 tons | 97% | 215864257 |
| EER2 | CH-RHP06F9-230VO | 18.0 | Non-ducted, up to 1.5 tons | 99% | 215864172 |
| Heating capacity at 5°F | CHV6-RS60URBMHH | 63,000 Btu/h | Ducted, 5 tons and up | 100% | 217026558 |
Cooper&Hunter size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.5(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 215864212 | 95.0(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 215864212 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 215864219 | 78.8(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 215864228 |
| Ducted, 2.5–3 tons | 84.7(50 is the typical model of its size class)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 217026552 | 83.6(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 215864276 |
| Ducted, 3.5–4.5 tons | 82.7(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 215864279 | 85.1(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 215864264 |
| Ducted, 5 tons and up | 88.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558 | 70.5(50 is the typical model of its size class)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 217026558 |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 215864172 | 96.2(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 215864172 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 215864191 | 86.8(50 is the typical model of its size class)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 215864171 |
| Non-ducted, 2.5–3 tons | 92.7(50 is the typical model of its size class)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 217026553 | 86.7(50 is the typical model of its size class)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 217026553 |
| Non-ducted, 3.5–4.5 tons | 94.6(50 is the typical model of its size class)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 217026556 | 82.7(50 is the typical model of its size class)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 217026556 |
| Non-ducted, 5 tons and up | 98.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559 | 83.5(50 is the typical model of its size class)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 217026559 |
Newest Cooper&Hunter certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CH-PQ55-230VOCooper&Hunterwith ducted air handler H,RG36*60+TXV+TD | 4 tons46,000 Btu/h · Ducted | 1.80 | 79% | 8.0 | 15.0 | CEE 25CEE 26XcelES CC | 6 | 218687381 |
| CH-PQ48-230VOCooper&Hunterwith ducted air handler H,RG84*48+TXV+TD | 4 tons45,000 Btu/h · Ducted | 1.80 | 82% | 8.4 | 14.5 | CEE 25CEE 26XcelES CC | 8 | 218687380 |
| CH-PQ36X-230VOCooper&Hunterwith ducted air handler H,RG34*36+TXV+TD | 3 tons35,800 Btu/h · Ducted | 1.86 | 99% | 9.2 | 15.2 | CEE 25CEE 26XcelES CC | 8 | 218687379 |
| CH-PQ33-230VOCooper&Hunterwith ducted air handler H,RG34*36+TXV+TD | 2.5 tons29,000 Btu/h · Ducted | 1.82 | 105% | 9.5 | 16.0 | CEE 25CEE 26XcelES CC | 12 | 218687378 |
| CH-PQ24-230VOCooper&Hunterwith ducted air handler H,RG21*24+TXV+TD | 2 tons23,000 Btu/h · Ducted | 1.70 | 86% | 8.8 | 15.2 | CEE 25CEE 26XcelES CC | 11 | 218687377 |
Compare Cooper&Hunter
Cooper&Hunter includes these brand names as listed in AHRI: C&H, Cooper&Hunter. Standards are checked against published thresholds; program rules beyond ratings are not checked.