- Insights
- Manufacturers
- Cooper&Hunter
Both views use the same certified data. This device remembers your choice.
Cooper&Hunter heat pump efficiency: 63 outdoor models compared
Cooper&Hunter has 63 heat pump outdoor models certified with this refrigerant group, in 279 AHRI-certified combinations. They are also sold as C&H. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Cooper&Hunter makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 63
- AHRI certifications
- 279
- Efficiency index
- 65%
- Typical model vs same-size, same-type peers (100 models)
- Meet CEE 2025
- 85.7%
- 54 models
How Cooper&Hunter compares with comparable models
- Cooper&Hunter
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index100 models scored | 65% | 1st of 29 | — |
| COP at 5°F100 models scored | 66% | 3rd of 29 | 2.10 |
| Capacity retention at 5°F100 models scored | 63% | 5th of 29 | 81% |
| HSPF2100 models scored | 74% | 1st of 29 | 10.2 |
| SEER2100 models scored | 66% | 2nd of 29 | 21.0 |
| EER2100 models scored | 59% | 9th of 29 | 12.0 |
| Heating capacity at 5°F100 models scored | 65% | 5th of 29 | 24,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7% | 54 |
| CEE 2026 Tier 1 (Split ASHP) | 84.1% | 53 |
| CEE Advanced Tier (Split ASHP) | 7.9% | 5 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 73% | 46 |
| DOE Cold Climate Heat Pump Challenge | 7.9% | 5 |
| ENERGY STAR Cold Climate | 71.4% | 45 |
Sizes and duct types offered
- Cooper&Hunter (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 12 | 74% | 74% | 79% | 76% |
| Ducted, 2 tons | 6 | 62% | 59% | 71% | 69% |
| Ducted, 2.5 to 3 tons | 15 | 67% | 64% | 81% | 67% |
| Ducted, 3.5 to 4.5 tons | 14 | 67% | 55% | 82% | 72% |
| Ducted, 5 tons and up | 3 | 67% | 75% | 91% | 80% |
| Non-ducted, up to 1.5 tons | 20 | 67% | 71% | 71% | 69% |
| Non-ducted, 2 tons | 4 | 61% | 89% | 62% | 42% |
| Non-ducted, 2.5 to 3 tons | 13 | 63% | 66% | 66% | 61% |
| Non-ducted, 3.5 to 4.5 tons | 11 | 50% | 50% | 63% | 45% |
| Non-ducted, 5 tons and up | 2 | 71% | 88% | 73% | 69% |
Every Cooper&Hunter model in the market
- Cooper&Hunter models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Cooper&Hunter in the cold
- All listed models (median, middle 50% and 80%)
- Cooper&Hunter (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Cooper&Hunter, 47°F | 63 | 100% | 100% | 100% | 100% | 100% |
| Cooper&Hunter, 17°F | 63 | 68% | 73% | 77% | 83% | 90% |
| Cooper&Hunter, 5°F | 63 | 58% | 63% | 70% | 81% | 89% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Cooper&Hunter, 47°F | 63 | 2.92 | 3.1 | 3.3 | 3.58 | 3.82 |
| Cooper&Hunter, 17°F | 63 | 2.12 | 2.21 | 2.31 | 2.52 | 2.69 |
| Cooper&Hunter, 5°F | 63 | 1.9 | 2 | 2.1 | 2.2 | 2.35 |
Source: NEEP ccASHP list · as of
Top Cooper&Hunter models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CHV6-RS60URBMHHCooper & Hunter | 5 tons60,000 Btu/h · Non-ducted | 100% | 2.30 | 11.0 | 63,000 | 21.5 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026559 | Non-ducted, 5 tons and up | 98.3 |
| 2CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 215864172 | Non-ducted, up to 1.5 tons | 97.0 |
| 3CHV6-RS48URBMHHCooper & Hunter | 4 tons48,000 Btu/h · Non-ducted | 100% | 2.40 | 10.8 | 54,000 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026556 | Non-ducted, 3.5 to 4.5 tons | 94.7 |
| 4CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MS | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 7,800 | 21.4 | CEE 25CEE 26XcelES CC | 7 | 215864212 | Ducted, up to 1.5 tons | 93.7 |
| 5CHV6-RS36URBMHHCooper & Hunter | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.45 | 10.8 | 42,000 | 23.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026553 | Non-ducted, 2.5 to 3 tons | 93.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 215864172 | Non-ducted, up to 1.5 tons | 96.6 | 97.0 | 96.1 | 97.0 |
| 2CH-RHP06F9-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS06MDT-MS | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 7 | 215864212 | Ducted, up to 1.5 tons | 95.1 | 93.7 | 96.5 | 93.7 |
| 3CH-RES09-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH09MMC | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 10 | 215864235 | Non-ducted, up to 1.5 tons | 93.3 | 90.4 | 96.2 | 90.4 |
| 4CH-RES24-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-PRO24MASTWM-230VI | 2 tons24,000 Btu/h · Non-ducted | 78% | 2.54 | 11.7 | 23.0 | 14.0 | CEE 25CEE 26XcelES CC | 9 | 215864171 | Non-ducted, 2 tons | 87.8 | 85.7 | 90.0 | 85.7 |
| 5CHV6-RS36URBMHHCooper & Hunter | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.45 | 10.8 | 23.0 | 13.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217026553 | Non-ducted, 2.5 to 3 tons | 87.2 | 93.3 | 81.1 | 93.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CHV6-RS48URBMHH | 2.40 | Non-ducted, 3.5 to 4.5 tons | 99% | 217026556 |
| Capacity retention at 5°F | CHV6-RS60URBMHH | 100% | Ducted, 5 tons and up | 100% | 217026558 |
| HSPF2 | CH-RHP06F9-230VO | 14.8 | Non-ducted, up to 1.5 tons | 99% | 215864172 |
| SEER2 | CH-R28MES-230VO | 25.0 | Non-ducted, 2.5 to 3 tons | 97% | 215864257 |
| EER2 | CH-RHP06F9-230VO | 18.0 | Non-ducted, up to 1.5 tons | 99% | 215864172 |
| Heating capacity at 5°F | CHV6-RS60URBMHH | 63,000 Btu/h | Ducted, 5 tons and up | 100% | 217026558 |
Cooper&Hunter size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 215864212 | 95.1(50 is the typical model of its size class)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 215864212 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 215864219 | 78.9(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 215864228 |
| Ducted, 2.5 to 3 tons | 84.9(50 is the typical model of its size class)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 217026552 | 83.9(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 215864276 |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 215864279 | 85.3(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 215864264 |
| Ducted, 5 tons and up | 88.6(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558 | 70.8(50 is the typical model of its size class)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 217026558 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 215864172 | 96.6(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 215864172 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 215864191 | 87.8(50 is the typical model of its size class)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 215864171 |
| Non-ducted, 2.5 to 3 tons | 93.3(50 is the typical model of its size class)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 217026553 | 87.2(50 is the typical model of its size class)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 217026553 |
| Non-ducted, 3.5 to 4.5 tons | 94.7(50 is the typical model of its size class)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 217026556 | 82.5(50 is the typical model of its size class)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 217026556 |
| Non-ducted, 5 tons and up | 98.3(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559 | 83.7(50 is the typical model of its size class)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 217026559 |
Newest Cooper&Hunter certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CH-PQ48-230VOCooper&Hunterwith ducted air handler AFM47J+TDR | 4 tons47,000 Btu/h · Ducted | 1.78 | 63% | 8.2 | 15.2 | CEE 25CEE 26XcelES CC | 9 | 218857290 |
| CH-ALT36HP24V-230VOCooper&Hunterwith ducted air handler CH-STM36AHU24V | 3 tons34,000 Btu/h · Ducted | 2.00 | 65% | 8.7 | 15.2 | None | 2 | 218828642 |
| CH-ALT30HP24V-230VOCooper&Hunterwith ducted air handler CH-STM30AHU24V | 2.5 tons29,000 Btu/h · Ducted | 1.90 | 68% | 9.0 | 17.5 | ES CC | 7 | 218828641 |
| CH-ALT24HP24V-230VOCooper&Hunterwith ducted air handler CH-STM18AHU24V | 1.5 tons20,000 Btu/h · Ducted | 1.55 | 72% | 7.5 | 16.2 | ES CC | 4 | 218828639 |
| CH-PQ36-230VOCooper&Hunterwith ducted air handler CH-ACL30-36C | 3 tons36,000 Btu/h · Ducted | 1.80 | 89% | 8.4 | 14.8 | CEE 25CEE 26XcelES CC | 3 | 218817472 |
Compare Cooper&Hunter
Cooper&Hunter includes these brand names as listed in AHRI: C&H, Cooper&Hunter. Standards are checked against published thresholds; program rules beyond ratings are not checked.