Cooper&Hunter vs Kaden heat pumps

Measured against models of the same size and duct type, Cooper&Hunter scores higher on 5 of the 6 ratings. Cooper&Hunter has 63 outdoor models, Kaden has 66 outdoor models. Kaden has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Cooper&Hunter and Kaden on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Cooper&Hunter scores higher on 5 of the 6 ratings.
  • Cooper&Hunter
  • Kaden
  • Other ranked manufacturers
Cooper&H…Kaden

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCooper&HunterKaden
Efficiency index64% (higher)median — · 1st ranked61% (higher)median —
COP at 5°F65% (higher)median 2.10 · 3rd ranked58% (higher)median 2.00
Capacity retention at 5°F62% (higher)median 80% · 5th ranked53% (higher)median 72%
HSPF273% (higher)median 10.2 · 1st ranked64% (higher)median 9.5
SEER265% (higher)median 21.0 · 2nd ranked63% (higher)median 19.3
EER258%median 12.0 · 9th ranked65%median 12.0
Heating capacity at 5°F65% (higher)median 24,000 Btu/h · 5th ranked55% (higher)median 19,800 Btu/h
Outdoor models6366
AHRI certifications260399

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCooper&HunterKaden
CEE 2025 Tier 1 (Split ASHP)85.7%54 models68.2%45 models
CEE 2026 Tier 1 (Split ASHP)84.1%53 models66.7%44 models
CEE Advanced Tier (Split ASHP)7.9%5 models3%2 models
Xcel Energy Colorado cold-climate ASHP (2025)73%46 models59.1%39 models
DOE Cold Climate Heat Pump Challenge7.9%5 models3%2 models
ENERGY STAR Cold Climate71.4%45 models57.6%38 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 10 groups where both have models
  • Cooper&Hunter
  • Kaden
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCooper&HunterKaden
Ducted, up to 1.5 tons12 · index 74%13 · index 72%
Ducted, 2 tons6 · index 62%9 · index 52%
Ducted, 2.5–3 tons15 · index 67%16 · index 54%
Ducted, 3.5–4.5 tons14 · index 67%19 · index 54%
Ducted, 5 tons and up3 · index 66%2 · index 63%
Non-ducted, up to 1.5 tons20 · index 65%13 · index 73%
Non-ducted, 2 tons4 · index 60%2 · index 82%
Non-ducted, 2.5–3 tons13 · index 62%12 · index 59%
Non-ducted, 3.5–4.5 tons11 · index 50%6 · index 68%
Non-ducted, 5 tons and up2 · index 71%2 · index 59%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCooper&HunterCold-climate score, best modelKadenCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 21586421285.5(50 is the typical model of its size class)KOB-HH-UUX18HP-2AAMAwith ducted air handler KIB-HH-UUX18AH3-2AAMA11 of 13 models qualify · AHRI 217970408
Ducted, 2 tons85.7(50 is the typical model of its size class)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 21586421985.7(50 is the typical model of its size class)KOB-HH-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMA6 of 9 models qualify · AHRI 215866654
Ducted, 2.5–3 tons84.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 21702655282.5(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA9 of 16 models qualify · AHRI 215866690
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 21586427982.7(50 is the typical model of its size class)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA10 of 19 models qualify · AHRI 215866693
Ducted, 5 tons and up88.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 21586417296.7(50 is the typical model of its size class)KOB-HH-PSX06HP-2AAMAwith ductless indoor unit KIB-PSX06WM-2AAMA12 of 13 models qualify · AHRI 215866628
Non-ducted, 2 tons89.4(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 21586419189.4(50 is the typical model of its size class)KOB-HH-PSX24HP-2AAMAwith ductless indoor unit KIB-PSX24CT-2AAMA2 of 2 models qualify · AHRI 215866644
Non-ducted, 2.5–3 tons92.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 21702655378.0(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA10 of 12 models qualify · AHRI 215866691
Non-ducted, 3.5–4.5 tons94.6(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 21702655673.4(50 is the typical model of its size class)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA6 of 6 models qualify · AHRI 215866694
Non-ducted, 5 tons and up98.2(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCooper&HunterAll-around score, best modelKadenAll-around score, best model
Ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 21586421286.7(50 is the typical model of its size class)KOB-HH-PSX09HP-2AAMAwith ducted air handler KIB-PSX09LS-2AAMA13 of 13 models have all five ratings · AHRI 215866649
Ducted, 2 tons78.8(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 21586422878.8(50 is the typical model of its size class)KOB-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMA9 of 9 models have all five ratings · AHRI 215866660
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 21586427683.6(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA16 of 16 models have all five ratings · AHRI 215866690
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 21586426485.1(50 is the typical model of its size class)KOB-PS548HP-2AAMAAlso listed as KOB-PS648HP-2AAMA19 of 19 models have all five ratings · AHRI 215866678
Ducted, 5 tons and up70.5(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 21702655862.5(50 is the typical model of its size class)KOB-PS555HP-2AAMAAlso listed as KOB-PS655HP-2AAMA2 of 2 models have all five ratings · AHRI 215866681
Non-ducted, up to 1.5 tons96.2(50 is the typical model of its size class)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 21586417296.2(50 is the typical model of its size class)KOB-HH-PSX06HP-2AAMAwith ductless indoor unit KIB-PSX06WM-2AAMA13 of 13 models have all five ratings · AHRI 215866628
Non-ducted, 2 tons86.8(50 is the typical model of its size class)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 21586417186.8(50 is the typical model of its size class)KOB-PSX24HP-2AAMAwith ductless indoor unit KIB-PSX24WM-2AAMA2 of 2 models have all five ratings · AHRI 215866638
Non-ducted, 2.5–3 tons86.7(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 21702655378.3(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA12 of 12 models have all five ratings · AHRI 215866689
Non-ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 21702655675.6(50 is the typical model of its size class)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA6 of 6 models have all five ratings · AHRI 215866692
Non-ducted, 5 tons and up83.5(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 21702655958.6(50 is the typical model of its size class)KOB-PS555HP-2AAMAAlso listed as KOB-PS655HP-2AAMA2 of 2 models have all five ratings · AHRI 215866680

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCooper&HunterKaden
COP at 5°Fbeats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5–4.5 tonsbeats 99% · 2.54KOB-PSX24HP-2AAMANon-ducted, 2 tons
Capacity retention at 5°Fbeats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and upbeats 98% · 120%KOB-HH-PSX09HP-2AAMADucted, up to 1.5 tons
HSPF2beats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 99% · 14.8KOB-HH-PSX06HP-2AAMANon-ducted, up to 1.5 tons
SEER2beats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5–3 tonsbeats 97% · 25.0KOB-PS327HP-2AAMAAlso listed as KOB-PS427HP-2AAMANon-ducted, 2.5–3 tons
EER2beats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 99% · 18.0KOB-HH-PSX06HP-2AAMANon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and upbeats 98% · 54,000 Btu/hKOB-HH-UUX60HP-2AAMADucted, 3.5–4.5 tons