Cooper&Hunter vs HITACHI heat pumps

Measured against models of the same size and duct type, Cooper&Hunter scores higher on 4 of the 6 ratings. Cooper&Hunter has 63 outdoor models, HITACHI has 66 outdoor models. HITACHI has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Cooper&Hunter and HITACHI on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Cooper&Hunter scores higher on 4 of the 6 ratings.
  • Cooper&Hunter
  • HITACHI
  • Other ranked manufacturers
Cooper&H…HITACHI

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCooper&HunterHITACHI
Efficiency index65%median — · 1st ranked67%median —
COP at 5°F66% (higher)median 2.10 · 3rd ranked65% (higher)median 2.10
Capacity retention at 5°F63% (higher)median 81% · 5th ranked62% (higher)median 79%
HSPF274% (higher)median 10.2 · 1st ranked73% (higher)median 10.5
SEER266% (higher)median 21.0 · 2nd ranked59% (higher)median 21.0
EER259%median 12.0 · 9th ranked75%median 12.9
Heating capacity at 5°F65%median 24,000 Btu/h · 5th ranked65%median 18,750 Btu/h
Outdoor models6366
AHRI certifications279172

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCooper&HunterHITACHI
CEE 2025 Tier 1 (Split ASHP)85.7%54 models97%64 models
CEE 2026 Tier 1 (Split ASHP)84.1%53 models97%64 models
CEE Advanced Tier (Split ASHP)7.9%5 models16.7%11 models
Xcel Energy Colorado cold-climate ASHP (2025)73%46 models84.8%56 models
DOE Cold Climate Heat Pump Challenge7.9%5 models16.7%11 models
ENERGY STAR Cold Climate71.4%45 models80.3%53 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Cooper&Hunter
  • HITACHI
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCooper&HunterHITACHI
Ducted, up to 1.5 tons12 · index 74%11 · index 68%
Ducted, 2 tons6 · index 62%6 · index 70%
Ducted, 2.5 to 3 tons15 · index 67%11 · index 74%
Ducted, 3.5 to 4.5 tons14 · index 67%7 · index 68%
Ducted, 5 tons and up3 · index 67%None
Non-ducted, up to 1.5 tons20 · index 67%34 · index 68%
Non-ducted, 2 tons4 · index 61%12 · index 69%
Non-ducted, 2.5 to 3 tons13 · index 63%13 · index 57%
Non-ducted, 3.5 to 4.5 tons11 · index 50%6 · index 57%
Non-ducted, 5 tons and up2 · index 71%1 · index 54%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCooper&HunterCold-climate score, best modelHITACHICold-climate score, best model
Ducted, up to 1.5 tons93.7(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS11 of 12 models qualify · AHRI 21586421280.8(50 is the typical model of its size class)PAS-18BLFASDQ1with ducted air handler PPIM-B18UFA1DQ9 of 11 models qualify · AHRI 215222822
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)CH-RHP24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models qualify · AHRI 21586421975.6(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class)CHV6-RS36URBMHH12 of 15 models qualify · AHRI 21702655287.4(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 213685840
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class) (higher)CH-RVHP48M-230VOAlso sold as C&H CH-RHP48M-230VO14 of 14 models qualify · AHRI 21586427972.8(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ3 of 7 models qualify · AHRI 213685842
Ducted, 5 tons and up88.6(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 3 models qualify · AHRI 217026558No models in this size class
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI14 of 20 models qualify · AHRI 21586417292.4(50 is the typical model of its size class)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ32 of 34 models qualify · AHRI 215222824
Non-ducted, 2 tons90.1(50 is the typical model of its size class)CH-RHP24-230VOwith ductless indoor unit CH-RSH24MCT4 of 4 models qualify · AHRI 21586419197.0(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825
Non-ducted, 2.5 to 3 tons93.3(50 is the typical model of its size class)CHV6-RS36URBMHH11 of 13 models qualify · AHRI 21702655397.3(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 13 models qualify · AHRI 215222826
Non-ducted, 3.5 to 4.5 tons94.7(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH9 of 11 models qualify · AHRI 21702655659.5(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PPFC-B48UFA1DQ3 of 6 models qualify · AHRI 214779302
Non-ducted, 5 tons and up98.3(50 is the typical model of its size class)CHV6-RS60URBMHH1 of 2 models qualify · AHRI 217026559None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCooper&HunterAll-around score, best modelHITACHIAll-around score, best model
Ducted, up to 1.5 tons95.1(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ducted air handler CH-RS06MDT-MS12 of 12 models have all five ratings · AHRI 21586421280.7(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ11 of 11 models have all five ratings · AHRI 215359321
Ducted, 2 tons78.9(50 is the typical model of its size class)CH-RES24-230VOwith ducted air handler CH-RS24MDT-HS6 of 6 models have all five ratings · AHRI 21586422880.2(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)CH-RVHP36M-230VOAlso sold as C&H CH-RHP36M-230VO15 of 15 models have all five ratings · AHRI 21586427691.3(50 is the typical model of its size class) (higher)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ11 of 11 models have all five ratings · AHRI 213685840
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)CH-R48MES-230VO14 of 14 models have all five ratings · AHRI 21586426483.4(50 is the typical model of its size class)PAS-48BUFASDQ1-LACwith ducted air handler PPIM-B48UFA1DQ7 of 7 models have all five ratings · AHRI 217450756
Ducted, 5 tons and up70.8(50 is the typical model of its size class)CHV6-RS60URBMHH3 of 3 models have all five ratings · AHRI 217026558No models in this size class
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class) (higher)CH-RHP06F9-230VOwith ductless indoor unit CH-PRO06MASTWM-230VI20 of 20 models have all five ratings · AHRI 21586417290.1(50 is the typical model of its size class)RAC-XJ12WHAAwith ductless indoor unit RAK-XJ12PHAA34 of 34 models have all five ratings · AHRI 215911631
Non-ducted, 2 tons87.8(50 is the typical model of its size class) (higher)CH-RES24-230VOwith ductless indoor unit CH-PRO24MASTWM-230VI4 of 4 models have all five ratings · AHRI 21586417185.7(50 is the typical model of its size class)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 215222825
Non-ducted, 2.5 to 3 tons87.2(50 is the typical model of its size class) (higher)CHV6-RS36URBMHH13 of 13 models have all five ratings · AHRI 21702655385.2(50 is the typical model of its size class)PAS-30BUFASDQ1with ductless indoor unit PCI-B30UFA1DQ13 of 13 models have all five ratings · AHRI 214723260
Non-ducted, 3.5 to 4.5 tons82.5(50 is the typical model of its size class) (higher)CHV6-RS48URBMHH11 of 11 models have all five ratings · AHRI 21702655670.2(50 is the typical model of its size class)PAS-48BUFASDQ1-LACwith ductless indoor unit PCI-B48UFA1DQ6 of 6 models have all five ratings · AHRI 217450780
Non-ducted, 5 tons and up83.7(50 is the typical model of its size class) (higher)CHV6-RS60URBMHH2 of 2 models have all five ratings · AHRI 21702655954.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCooper&HunterHITACHI
COP at 5°Fbeats 99% · 2.40CHV6-RS48URBMHHNon-ducted, 3.5 to 4.5 tonsbeats 100% · 2.50PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 100% · 100%CHV6-RS60URBMHHDucted, 5 tons and upbeats 100% · 147%RAC-XJ09WHAANon-ducted, up to 1.5 tons
HSPF2beats 99% · 14.8CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 100% · 12.0PAS-30BUFASDQ1Non-ducted, 2.5 to 3 tons
SEER2beats 97% · 25.0CH-R28MES-230VONon-ducted, 2.5 to 3 tonsbeats 100% · 24.2HVAHP048C23S*Non-ducted, 3.5 to 4.5 tons
EER2beats 99% · 18.0CH-RHP06F9-230VONon-ducted, up to 1.5 tonsbeats 100% · 16.8HVAHP036C23S*Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 100% · 63,000 Btu/hCHV6-RS60URBMHHDucted, 5 tons and upbeats 100% · 23,000 Btu/hRAC-XJ18WHAAAlso listed as RAC-XJ18WHBANon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Cooper&Hunter vs HITACHI: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Cooper&Hunter (median, middle 50%)
  • HITACHI (median, middle 50%)
Heating capacity, % of its 47°F maximum70%75%COP at maximum capacity2.102.10

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Cooper&Hunter: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F63100%100%100%100%100%
Cooper&Hunter, 17°F6368%73%77%83%90%
Cooper&Hunter, 5°F6358%63%70%81%89%
Cooper&Hunter: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Cooper&Hunter, 47°F632.923.13.33.583.82
Cooper&Hunter, 17°F632.122.212.312.522.69
Cooper&Hunter, 5°F631.922.12.22.35
HITACHI: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HITACHI, 47°F45100%100%100%100%100%
HITACHI, 17°F4565%71%79%88%97%
HITACHI, 5°F4558%65%75%80%83%
HITACHI: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HITACHI, 47°F452.72.963.283.533.83
HITACHI, 17°F452.152.22.32.612.86
HITACHI, 5°F451.81.982.12.22.4

Source: NEEP ccASHP list · as of