- Insights
- Manufacturers
- HITACHI
Both views use the same certified data. This device remembers your choice.
HITACHI heat pump efficiency: 66 outdoor models compared
HITACHI has 66 heat pump outdoor models certified with this refrigerant group, in 172 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes HITACHI makes. HITACHI has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 66
- AHRI certifications
- 172
- Efficiency index
- 67%
- Typical model vs same-size, same-type peers (101 models)
- Meet CEE 2025
- 97%
- 64 models
How HITACHI compares with comparable models
- HITACHI
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index101 models scored | 67% | Not ranked | — |
| COP at 5°F101 models scored | 65% | Not ranked | 2.10 |
| Capacity retention at 5°F101 models scored | 62% | Not ranked | 79% |
| HSPF2101 models scored | 73% | Not ranked | 10.5 |
| SEER2101 models scored | 59% | Not ranked | 21.0 |
| EER2101 models scored | 75% | Not ranked | 12.9 |
| Heating capacity at 5°F101 models scored | 65% | Not ranked | 18,750 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 97% | 64 |
| CEE 2026 Tier 1 (Split ASHP) | 97% | 64 |
| CEE Advanced Tier (Split ASHP) | 16.7% | 11 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 84.8% | 56 |
| DOE Cold Climate Heat Pump Challenge | 16.7% | 11 |
| ENERGY STAR Cold Climate | 80.3% | 53 |
Sizes and duct types offered
- HITACHI (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 68% | 65% | 64% | 67% |
| Ducted, 2 tons | 6 | 70% | 68% | 76% | 64% |
| Ducted, 2.5 to 3 tons | 11 | 74% | 56% | 88% | 78% |
| Ducted, 3.5 to 4.5 tons | 7 | 68% | 46% | 81% | 85% |
| Non-ducted, up to 1.5 tons | 34 | 68% | 71% | 77% | 52% |
| Non-ducted, 2 tons | 12 | 69% | 75% | 76% | 49% |
| Non-ducted, 2.5 to 3 tons | 13 | 57% | 68% | 68% | 40% |
| Non-ducted, 3.5 to 4.5 tons | 6 | 57% | 49% | 27% | 71% |
| Non-ducted, 5 tons and up | 1 | 54% | 18% | 69% | 61% |
Every HITACHI model in the market
- HITACHI models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
HITACHI in the cold
- All listed models (median, middle 50% and 80%)
- HITACHI (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 100% | 100% | 100% | 100% | 100% |
| HITACHI, 17°F | 45 | 65% | 71% | 79% | 88% | 97% |
| HITACHI, 5°F | 45 | 58% | 65% | 75% | 80% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HITACHI, 47°F | 45 | 2.7 | 2.96 | 3.28 | 3.53 | 3.83 |
| HITACHI, 17°F | 45 | 2.15 | 2.2 | 2.3 | 2.61 | 2.86 |
| HITACHI, 5°F | 45 | 1.8 | 1.98 | 2.1 | 2.2 | 2.4 |
Source: NEEP ccASHP list · as of
Top HITACHI models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PAS-30BLFASDQ1HITACHI · airCore700with ductless indoor unit PCI-B30UFA1DQ | 2.5 tons30,000 Btu/h · Non-ducted | 103% | 2.40 | 12.0 | 32,800 | 20.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215222826 | Non-ducted, 2.5 to 3 tons | 97.3 |
| 2PAS-24BLFASDQ1HITACHI · airCore700with ductless indoor unit PCI-B24UFA1DQ | 2 tons24,000 Btu/h · Non-ducted | 106% | 2.40 | 12.2 | 27,600 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 215222825 | Non-ducted, 2 tons | 97.0 |
| 3PAS-30BUFASDQ1HITACHI · airCore700with ductless indoor unit PCI-B30UFA1DQ | 2.5 tons30,000 Btu/h · Non-ducted | 102% | 2.30 | 12.0 | 32,600 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 214723260 | Non-ducted, 2.5 to 3 tons | 96.9 |
| 4PAS-36BLFASDQ1HITACHI · airCore700with ductless indoor unit PCI-B36UFA1DQ | 3 tons36,000 Btu/h · Non-ducted | 104% | 2.10 | 11.8 | 39,500 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 215222842 | Non-ducted, 2.5 to 3 tons | 95.0 |
| 5RAC-GJ24WHAAHitachi · airHome 600with ductless indoor unit RAK-GJ24PHAAAlso listed as RAC-GJ24WHBA | 2 tons22,000 Btu/h · Non-ducted | 112% | 2.34 | 11.0 | 24,700 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215413021 | Non-ducted, 2 tons | 94.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PAS-30BUFASDQ1HITACHI · airCore700with ducted air handler PPIM-B30UFA1DQ | 2.5 tons30,000 Btu/h · Ducted | 99% | 2.10 | 10.8 | 19.6 | 13.0 | CEE 25CEE 26XcelES CC | 7 | 213685840 | Ducted, 2.5 to 3 tons | 91.3 | 87.4 | 95.1 | 87.4 |
| 2PAS-36BUFASDQ1HITACHI · airCore700with ducted air handler PPIM-B36UFA1DQ | 3 tons36,000 Btu/h · Ducted | 92% | 2.20 | 10.6 | 19.6 | 12.8 | CEE 25CEE 26XcelES CC | 7 | 213685841 | Ducted, 2.5 to 3 tons | 90.5 | 87.0 | 94.1 | 87.0 |
| 3RAC-XJ12WHAAHitachi · airHome 800with ductless indoor unit RAK-XJ12PHAA | 1 ton12,500 Btu/h · Non-ducted | 122% | 2.12 | 11.5 | 25.0 | 14.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215911631 | Non-ducted, up to 1.5 tons | 90.1 | 90.4 | 89.7 | 90.4 |
| 4PAS-30BUFASDQ1-LACHITACHI · airCore700 LACwith ducted air handler PPIM-B30UFA1DQ | 2.5 tons30,000 Btu/h · Ducted | 94% | 2.13 | 10.0 | 20.0 | 13.0 | CEE 25CEE 26XcelES CC | 4 | 217450754 | Ducted, 2.5 to 3 tons | 89.1 | 81.7 | 96.4 | 81.7 |
| 5PAS-30BLFASDQ1HITACHI · airCore700with ducted air handler PPIM-B30UFA1DQ | 2.5 tons30,000 Btu/h · Ducted | 98% | 2.10 | 10.8 | 19.0 | 12.8 | CEE 25CEE 26XcelES CC | 3 | 215222843 | Ducted, 2.5 to 3 tons | 88.6 | 87.2 | 90.0 | 87.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | PAS-30BUFASDQ1 | 2.50 | Non-ducted, 2.5 to 3 tons | 100% | 214779300 |
| Capacity retention at 5°F | RAC-XJ09WHAA | 147% | Non-ducted, up to 1.5 tons | 100% | 215911630 |
| HSPF2 | PAS-30BUFASDQ1 | 12.0 | Non-ducted, 2.5 to 3 tons | 100% | 214723260 |
| SEER2 | HVAHP048C23S* | 24.2 | Non-ducted, 3.5 to 4.5 tons | 100% | 217036517 |
| EER2 | HVAHP036C23S* | 16.8 | Non-ducted, 2.5 to 3 tons | 100% | 217036516 |
| Heating capacity at 5°F | RAC-XJ18WHAAAlso listed as RAC-XJ18WHBA | 23,000 Btu/h | Non-ducted, up to 1.5 tons | 100% | 215911632 |
HITACHI size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 80.8(50 is the typical model of its size class)PAS-18BLFASDQ1with ducted air handler PPIM-B18UFA1DQ9 of 11 models qualify · AHRI 215222822 | 80.7(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ11 of 11 models have all five ratings · AHRI 215359321 |
| Ducted, 2 tons | 75.6(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823 | 80.2(50 is the typical model of its size class)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753 |
| Ducted, 2.5 to 3 tons | 87.4(50 is the typical model of its size class)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 213685840 | 91.3(50 is the typical model of its size class)PAS-30BUFASDQ1with ducted air handler PPIM-B30UFA1DQ11 of 11 models have all five ratings · AHRI 213685840 |
| Ducted, 3.5 to 4.5 tons | 72.8(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ3 of 7 models qualify · AHRI 213685842 | 83.4(50 is the typical model of its size class)PAS-48BUFASDQ1-LACwith ducted air handler PPIM-B48UFA1DQ7 of 7 models have all five ratings · AHRI 217450756 |
| Non-ducted, up to 1.5 tons | 92.4(50 is the typical model of its size class)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ32 of 34 models qualify · AHRI 215222824 | 90.1(50 is the typical model of its size class)RAC-XJ12WHAAwith ductless indoor unit RAK-XJ12PHAA34 of 34 models have all five ratings · AHRI 215911631 |
| Non-ducted, 2 tons | 97.0(50 is the typical model of its size class)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825 | 85.7(50 is the typical model of its size class)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 215222825 |
| Non-ducted, 2.5 to 3 tons | 97.3(50 is the typical model of its size class)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 13 models qualify · AHRI 215222826 | 85.2(50 is the typical model of its size class)PAS-30BUFASDQ1with ductless indoor unit PCI-B30UFA1DQ13 of 13 models have all five ratings · AHRI 214723260 |
| Non-ducted, 3.5 to 4.5 tons | 59.5(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PPFC-B48UFA1DQ3 of 6 models qualify · AHRI 214779302 | 70.2(50 is the typical model of its size class)PAS-48BUFASDQ1-LACwith ductless indoor unit PCI-B48UFA1DQ6 of 6 models have all five ratings · AHRI 217450780 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 54.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518 |
Newest HITACHI certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| RAM-X36N4HBAHitachi · airHome Multi Pro | 3 tons34,400 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.78 | 93% | 10.5 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218788008 |
| YRACGJ12WHBAHitachi · airHome 600with ductless indoor unit YRAKGJ12PHBA | 1 ton12,000 Btu/h · Non-ducted | 2.20 | 76% | 11.1 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218731650 |
| RAC-GJ12WHBAHitachi · airHome 600with ductless indoor unit RAK-GJ12PHBA | 1 ton12,000 Btu/h · Non-ducted | 2.20 | 76% | 11.1 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218731649 |
| PAS-36BLFASDQ1HITACHI · airCore700with ducted air handler JPE36B3XD2HS2 | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.00 | 96% | 10.2 | 16.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 218700908 |
| PAS-24BLFASDQ1HITACHI · airCore700with ducted air handler JPE24B3XC2HS2 | 2 tons24,000 Btu/h · Ducted and non-ducted | 2.00 | 98% | 9.7 | 15.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 218700907 |
Compare HITACHI
HITACHI includes these brand names as listed in AHRI: HITACHI. Standards are checked against published thresholds; program rules beyond ratings are not checked.