HITACHI vs Kaden heat pumps
Measured against models of the same size and duct type, HITACHI scores higher on 5 of the 6 ratings. HITACHI has 63 outdoor models, Kaden has 66 outdoor models. HITACHI and Kaden have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- HITACHI
- Kaden
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | HITACHI | Kaden |
|---|---|---|
| Efficiency index | 68% (higher)median — | 61% (higher)median — |
| COP at 5°F | 66% (higher)median 2.13 | 58% (higher)median 2.00 |
| Capacity retention at 5°F | 60% (higher)median 79% | 53% (higher)median 72% |
| HSPF2 | 70% (higher)median 10.0 | 64% (higher)median 9.5 |
| SEER2 | 63%median 21.8 | 63%median 19.3 |
| EER2 | 75% (higher)median 13.0 | 65% (higher)median 12.0 |
| Heating capacity at 5°F | 64% (higher)median 18,500 Btu/h | 55% (higher)median 19,800 Btu/h |
| Outdoor models | 63 | 66 |
| AHRI certifications | 164 | 399 |
Share of models meeting each standard
| Standard | HITACHI | Kaden |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 95.2%60 models | 68.2%45 models |
| CEE 2026 Tier 1 (Split ASHP) | 95.2%60 models | 66.7%44 models |
| CEE Advanced Tier (Split ASHP) | 17.5%11 models | 3%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 82.5%52 models | 59.1%39 models |
| DOE Cold Climate Heat Pump Challenge | 17.5%11 models | 3%2 models |
| ENERGY STAR Cold Climate | 79.4%50 models | 57.6%38 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- HITACHI
- Kaden
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | HITACHI | Kaden |
|---|---|---|
| Ducted, up to 1.5 tons | 10 · index 70% | 13 · index 72% |
| Ducted, 2 tons | 6 · index 71% | 9 · index 52% |
| Ducted, 2.5–3 tons | 11 · index 74% | 16 · index 54% |
| Ducted, 3.5–4.5 tons | 6 · index 70% | 19 · index 54% |
| Ducted, 5 tons and up | None | 2 · index 63% |
| Non-ducted, up to 1.5 tons | 33 · index 70% | 13 · index 73% |
| Non-ducted, 2 tons | 12 · index 67% | 2 · index 82% |
| Non-ducted, 2.5–3 tons | 12 · index 58% | 12 · index 59% |
| Non-ducted, 3.5–4.5 tons | 5 · index 58% | 6 · index 68% |
| Non-ducted, 5 tons and up | 1 · index 54% | 2 · index 59% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | HITACHICold-climate score, best model | KadenCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.3(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ8 of 10 models qualify · AHRI 215359321 | 85.5(50 is the typical model of its size class) (higher)KOB-HH-UUX18HP-2AAMAwith ducted air handler KIB-HH-UUX18AH3-2AAMA11 of 13 models qualify · AHRI 217970408 |
| Ducted, 2 tons | 75.5(50 is the typical model of its size class)PAS-24BLFASDQ1with ducted air handler PPIM-B24UFA1DQ6 of 6 models qualify · AHRI 215222823 | 85.7(50 is the typical model of its size class) (higher)KOB-HH-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMA6 of 9 models qualify · AHRI 215866654 |
| Ducted, 2.5–3 tons | 83.7(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ducted air handler PPIM-B30UFA1DQ9 of 11 models qualify · AHRI 215222843 | 82.5(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA9 of 16 models qualify · AHRI 215866690 |
| Ducted, 3.5–4.5 tons | 72.7(50 is the typical model of its size class)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ2 of 6 models qualify · AHRI 213685842 | 82.7(50 is the typical model of its size class) (higher)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA10 of 19 models qualify · AHRI 215866693 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 91.6(50 is the typical model of its size class)PAS-18BLFASDQ1with ductless indoor unit PCI-B18UFA1DQ29 of 33 models qualify · AHRI 215222824 | 96.7(50 is the typical model of its size class) (higher)KOB-HH-PSX06HP-2AAMAwith ductless indoor unit KIB-PSX06WM-2AAMA12 of 13 models qualify · AHRI 215866628 |
| Non-ducted, 2 tons | 93.8(50 is the typical model of its size class) (higher)PAS-24BLFASDQ1with ductless indoor unit PCI-B24UFA1DQ12 of 12 models qualify · AHRI 215222825 | 89.4(50 is the typical model of its size class)KOB-HH-PSX24HP-2AAMAwith ductless indoor unit KIB-PSX24CT-2AAMA2 of 2 models qualify · AHRI 215866644 |
| Non-ducted, 2.5–3 tons | 97.4(50 is the typical model of its size class) (higher)PAS-30BLFASDQ1with ductless indoor unit PCI-B30UFA1DQ9 of 12 models qualify · AHRI 215222826 | 78.0(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA10 of 12 models qualify · AHRI 215866691 |
| Non-ducted, 3.5–4.5 tons | 59.0(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PCI-B48UFA1DQ2 of 5 models qualify · AHRI 214723262 | 73.4(50 is the typical model of its size class) (higher)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA6 of 6 models qualify · AHRI 215866694 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | HITACHIAll-around score, best model | KadenAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.9(50 is the typical model of its size class)PAS-12BLFASDQ1with ducted air handler PPIM-B12UFA1DQ10 of 10 models have all five ratings · AHRI 215359321 | 86.7(50 is the typical model of its size class) (higher)KOB-HH-PSX09HP-2AAMAwith ducted air handler KIB-PSX09LS-2AAMA13 of 13 models have all five ratings · AHRI 215866649 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class) (higher)PAS-24BUFASDQ1-LACwith ducted air handler PPIM-B24UFA1DQ6 of 6 models have all five ratings · AHRI 217450753 | 78.8(50 is the typical model of its size class)KOB-PSX24HP-2AAMAwith ducted air handler KIB-PSX24HS-2AAMA9 of 9 models have all five ratings · AHRI 215866660 |
| Ducted, 2.5–3 tons | 90.1(50 is the typical model of its size class) (higher)PAS-36BLFASDQ1with ducted air handler PPIM-B36UFA1DQ11 of 11 models have all five ratings · AHRI 215222841 | 83.6(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA16 of 16 models have all five ratings · AHRI 215866690 |
| Ducted, 3.5–4.5 tons | 85.7(50 is the typical model of its size class) (higher)PAS-48BUFASDQ1with ducted air handler PPIM-B48UFA1DQ6 of 6 models have all five ratings · AHRI 213685842 | 85.1(50 is the typical model of its size class)KOB-PS548HP-2AAMAAlso listed as KOB-PS648HP-2AAMA19 of 19 models have all five ratings · AHRI 215866678 |
| Ducted, 5 tons and up | No models in this size class | 62.5(50 is the typical model of its size class)KOB-PS555HP-2AAMAAlso listed as KOB-PS655HP-2AAMA2 of 2 models have all five ratings · AHRI 215866681 |
| Non-ducted, up to 1.5 tons | 90.5(50 is the typical model of its size class)PAS-12BLFASDQ1with ductless indoor unit PCIM-B12UFA1DQ31 of 33 models have all five ratings · AHRI 215359322 | 96.2(50 is the typical model of its size class) (higher)KOB-HH-PSX06HP-2AAMAwith ductless indoor unit KIB-PSX06WM-2AAMA13 of 13 models have all five ratings · AHRI 215866628 |
| Non-ducted, 2 tons | 81.6(50 is the typical model of its size class)PAS-24BUFASDQ1-LACwith ductless indoor unit PCI-B24UFA1DQ12 of 12 models have all five ratings · AHRI 217450777 | 86.8(50 is the typical model of its size class) (higher)KOB-PSX24HP-2AAMAwith ductless indoor unit KIB-PSX24WM-2AAMA2 of 2 models have all five ratings · AHRI 215866638 |
| Non-ducted, 2.5–3 tons | 93.9(50 is the typical model of its size class) (higher)PAS-36BLFASDQ1with ductless indoor unit PCI-B36UFA1DQ12 of 12 models have all five ratings · AHRI 215222842 | 78.3(50 is the typical model of its size class)KOB-HH-PS436HP-2AAMAAlso listed as KOB-HH-PS536HP-2AAMA12 of 12 models have all five ratings · AHRI 215866689 |
| Non-ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class)PAS-48BUFASDQ1with ductless indoor unit PCI-B48UFA1DQ5 of 5 models have all five ratings · AHRI 214723262 | 75.6(50 is the typical model of its size class) (higher)KOB-HH-PS548HP-2AAMAAlso listed as KOB-HH-PS648HP-2AAMA6 of 6 models have all five ratings · AHRI 215866692 |
| Non-ducted, 5 tons and up | 54.1(50 is the typical model of its size class)HVAHP060C23S*1 of 1 models have all five ratings · AHRI 217036518 | 58.6(50 is the typical model of its size class) (higher)KOB-PS555HP-2AAMAAlso listed as KOB-PS655HP-2AAMA2 of 2 models have all five ratings · AHRI 215866680 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | HITACHI | Kaden |
|---|---|---|
| COP at 5°F | beats 100% · 2.50PAS-30BUFASDQ1Non-ducted, 2.5–3 tons | beats 99% · 2.54KOB-PSX24HP-2AAMANon-ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 123%RAC-XJ24WHBANon-ducted, 2 tons | beats 98% · 120%KOB-HH-PSX09HP-2AAMADucted, up to 1.5 tons |
| HSPF2 | beats 98% · 11.0RAM-X36N4HAADucted, 2.5–3 tons | beats 99% · 14.8KOB-HH-PSX06HP-2AAMANon-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 24.2HVAHP048C23S*Non-ducted, 3.5–4.5 tons | beats 97% · 25.0KOB-PS327HP-2AAMAAlso listed as KOB-PS427HP-2AAMANon-ducted, 2.5–3 tons |
| EER2 | beats 100% · 16.8HVAHP036C23S*Non-ducted, 2.5–3 tons | beats 99% · 18.0KOB-HH-PSX06HP-2AAMANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 23,000 Btu/hRAC-XJ18WHAAAlso listed as RAC-XJ18WHBANon-ducted, up to 1.5 tons | beats 98% · 54,000 Btu/hKOB-HH-UUX60HP-2AAMADucted, 3.5–4.5 tons |