DOE Cold Climate Heat Pump Challenge: 322 qualifying heat pumps
Rating thresholds from the DOE Residential Cold Climate Heat Pump Technology Challenge.
New to heat pump ratings? The Simple view explains them in plain words →
U.S. Department of EnergyData as of updated · sources
- Share of models
- 2.6%
- Qualifying models
- 322
- Qualifying certifications
- 1,066
- Paths
- 1
Criteria
| Path | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|
| Challenge specification | ≥ 8.5 | ≥ 2.1 | ≥ 100% |
Source: U.S. Department of Energy
Where the thresholds fall
Every model's representative certification on each rating DOE CCHP checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 12 |
| 1.40 to under 1.50 | 79 |
| 1.50 to under 1.60 | 176 |
| 1.60 to under 1.70 | 335 |
| 1.70 to under 1.80 | 1,180 |
| 1.80 to under 1.90 | 2,237 |
| 1.90 to under 2.00 | 1,350 |
| 2.00 to under 2.10 | 2,426 |
| 2.10 to under 2.20 | 1,325 |
| 2.20 to under 2.30 | 778 |
| 2.30 to under 2.40 | 512 |
| 2.40 to under 2.50 | 260 |
| 2.50 to under 2.60 | 215 |
| 2.60 to under 2.70 | 132 |
| 2.70 to under 2.80 | 80 |
| 2.80 to under 2.90 | 51 |
| 2.90 to under 3.00 | 30 |
| 3.00 and above | 40 |
| Baseline: median | 2.00 |
| Baseline: DOE CCHP 2.1 | 2.10 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 28 |
| 35 to under 40% | 337 |
| 40 to under 45% | 467 |
| 45 to under 50% | 520 |
| 50 to under 55% | 566 |
| 55 to under 60% | 526 |
| 60 to under 65% | 683 |
| 65 to under 70% | 763 |
| 70 to under 75% | 2,400 |
| 75 to under 80% | 1,157 |
| 80 to under 85% | 798 |
| 85 to under 90% | 375 |
| 90 to under 95% | 719 |
| 95 to under 100% | 580 |
| 100 to under 105% | 757 |
| 105 to under 110% | 151 |
| 110 to under 115% | 148 |
| 115 to under 120% | 27 |
| 120 to under 125% | 41 |
| 125 to under 130% | 19 |
| 130% and above | 40 |
| Baseline: median | 72% |
| Baseline: DOE CCHP 100% | 100% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 41 |
| 6.5 to under 6.8 | 983 |
| 6.8 to under 7.0 | 64 |
| 7.0 to under 7.3 | 528 |
| 7.3 to under 7.5 | 15 |
| 7.5 to under 7.8 | 1,110 |
| 7.8 to under 8.0 | 383 |
| 8.0 to under 8.3 | 721 |
| 8.3 to under 8.5 | 177 |
| 8.5 to under 8.8 | 1,449 |
| 8.8 to under 9.0 | 196 |
| 9.0 to under 9.3 | 1,502 |
| 9.3 to under 9.5 | 132 |
| 9.5 to under 9.8 | 1,368 |
| 9.8 to under 10.0 | 306 |
| 10.0 to under 10.3 | 1,626 |
| 10.3 to under 10.5 | 228 |
| 10.5 to under 10.8 | 602 |
| 10.8 to under 11.0 | 80 |
| 11.0 to under 11.3 | 294 |
| 11.3 to under 11.5 | 59 |
| 11.5 to under 11.8 | 122 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 27 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 92 |
| 12.8 to under 13.0 | 0 |
| 13.0 to under 13.3 | 23 |
| 13.3 to under 13.5 | 9 |
| 13.5 to under 13.8 | 43 |
| 13.8 to under 14.0 | 34 |
| 14.0 and above | 62 |
| Baseline: median | 9.0 |
| Baseline: DOE CCHP 8.5 | 8.5 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons3.6% · 171 of 4,712
- 2 tons2.2% · 38 of 1,747
- 2.5–3 tons2.1% · 58 of 2,722
- 3.5–4.5 tons2% · 53 of 2,687
- 5 tons and up0.4% · 2 of 458
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 3.6% · 171 of 4,712 |
| 2 tons | 2.2% · 38 of 1,747 |
| 2.5–3 tons | 2.1% · 58 of 2,722 |
| 3.5–4.5 tons | 2% · 53 of 2,687 |
| 5 tons and up | 0.4% · 2 of 458 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 1.9% | 114 / 6,060 |
| Non-ducted | 2.4% | 97 / 4,081 |
| Ducted and non-ducted | 5.1% | 111 / 2,185 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230C1HVAC · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD | 1HVAC | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 216032267 |
| 2ACIQ-18-HPD1HVAC · ACIQ Serieswith ducted air handler ACIQ-18-PAH | 1HVAC | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 216032234 |
| 3ACIQ-60-HP321HVAC · R32 Extreme Heat Unitarywith ducted air handler ACIQ-60-AH32 | 1HVAC | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215387237 |
| 4ACIQ-06ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD | ACIQ | 0.5 tons6,000 Btu/h · Non-ducted | 2.40 | 110% | 14.8 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 216032333 |
| 5ACIQ-18-HPDACIQwith ducted air handler CM24A2J+TDR | ACIQ | 1.5 tons16,100 Btu/h · Ducted | 2.93 | 79% | 8.5 | 15.2 | CEE 25CEE 26CEE AdvXcelDOEES CC | 11 | 217617061 |
| 6ACIQ-60-HP32ACIQ · R32 Extreme Heat Unitarywith ducted air handler ACIQ-60-AH32 | ACIQ | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215387241 |
| 7KUSXB241AADPwith ducted air handler FC*G31*30+TXV+TD | ADP | 1.5 tons20,600 Btu/h · Ducted | 2.12 | 100% | 8.5 | 15.0 | CEE AdvXcelDOE | 24 | 217730109 |
| 8AO25-06N2-M1HAI AIR CONDITIONING · AO Serieswith ducted air handler AL-06N2-M1 | AI AIR CONDITIONING | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215866781 |
| 9AUO19-18N2-M3HAI AIR CONDITIONING · AU Serieswith ducted air handler AUH3-18N2-AM3E | AI AIR CONDITIONING | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 215866713 |
| 10AFMKH36-H2AIR MAX · AIRMAX Free Match | AIR MAX | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218396984 |
| 11ATMO24AXR32AIR TECH | AIR TECH | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 108% | 10.5 | 24.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 217489299 |
| 12DXH36FMK3IHAireForce · Multizone Outdoors | AireForce | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215746283 |
| 13UXH48-60MSK3IHAireForce · E Serieswith ducted air handler UMD60MSK3IH | AireForce | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 217138201 |
| 14DXH36FMK3IHAIRTEMP · Multizone Outdoors | AIRTEMP | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215746298 |
| 15UXH48-60MSK3IHAIRTEMP · E Serieswith ducted air handler UMD60MSK3IH | AIRTEMP | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 6 | 217138205 |
| 16AP4M36HP230VMOAPOWER | APOWER | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 216441120 |
| 17AP5M36HP230VMOAPOWER | APOWER | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 100% | 10.0 | 21.0 | CEE 25CEE 26CEE AdvXcelDOE | 3 | 215832441 |
| 18APFH60HP230VAO-R32APOWER · E Serieswith ducted air handler APF60HP230VAI-R32 | APOWER | 4.5 tons53,000 Btu/h · Ducted | 2.10 | 100% | 10.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOE | 2 | 217655831 |
| 19AHU3G-18HFN-BAprodr · AHU3G Serieswith ducted air handler AHU3G-18HFN-A | Aprodr | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218045630 |
| 20AB-GTMH24-230VOArmbridge · Multi-spilt series | Armbridge | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 108% | 10.5 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 218059653 |
| 21AM3-H24/2DR3BAUX · C-Series | AUX | 2 tons24,000 Btu/h · Non-ducted | 2.10 | 108% | 10.5 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214097943 |
| 22ASUM24HPMULOAUX · C-Series | AUX | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 108% | 10.5 | 24.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 214291431 |
| 23MYUSA24NA23BCH19-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA24NA23BCH19-I | Bestcold | 2 tons24,000 Btu/h · Ducted | 2.20 | 100% | 9.5 | 18.5 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217896463 |
| 24BMS626HHYCBLUERIDGE · BMS Serieswith ducted air handler BMC6LCD | BlueRidge | 0.5 tons6,500 Btu/h · Ducted and non-ducted | 2.41 | 98% | 13.8 | 21.4 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215853938 |
| 25BMSAH18HHCBLUERIDGE · BMS Serieswith ducted air handler BMS3AH18I | BlueRidge | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 215853875 |