- Insights
- Manufacturers
- Aprodr
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Aprodr heat pump efficiency: 44 outdoor models compared
Aprodr has 44 heat pump outdoor models certified with this refrigerant group, in 67 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Aprodr makes. Aprodr has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 44
- AHRI certifications
- 67
- Efficiency index
- 59%
- Typical model vs same-size, same-type peers (55 models)
- Meet CEE 2025
- 90.9%
- 40 models
How Aprodr compares with comparable models
- Aprodr
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index55 models scored | 59% | Not ranked | — |
| COP at 5°F55 models scored | 65% | Not ranked | 2.04 |
| Capacity retention at 5°F55 models scored | 45% | Not ranked | 72% |
| HSPF255 models scored | 66% | Not ranked | 9.8 |
| SEER255 models scored | 65% | Not ranked | 20.1 |
| EER255 models scored | 54% | Not ranked | 12.0 |
| Heating capacity at 5°F55 models scored | 52% | Not ranked | 18,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 90.9% | 40 |
| CEE 2026 Tier 1 (Split ASHP) | 86.4% | 38 |
| CEE Advanced Tier (Split ASHP) | 2.3% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75% | 33 |
| DOE Cold Climate Heat Pump Challenge | 2.3% | 1 |
| ENERGY STAR Cold Climate | 77.3% | 34 |
Sizes and duct types offered
- Aprodr (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 72% | 84% | 79% | 74% |
| Ducted, 2 tons | 4 | 67% | 59% | 79% | 75% |
| Ducted, 2.5–3 tons | 6 | 61% | 60% | 78% | 66% |
| Ducted, 3.5–4.5 tons | 6 | 62% | 45% | 76% | 67% |
| Ducted, 5 tons and up | 2 | 64% | 78% | 88% | 83% |
| Non-ducted, up to 1.5 tons | 19 | 59% | 67% | 64% | 66% |
| Non-ducted, 2 tons | 5 | 55% | 63% | 53% | 67% |
| Non-ducted, 2.5–3 tons | 4 | 42% | 61% | 45% | 49% |
| Non-ducted, 3.5–4.5 tons | 2 | 43% | 87% | 32% | 40% |
| Non-ducted, 5 tons and up | 1 | 27% | 42% | 18% | 16% |
Every Aprodr model in the market
- Aprodr models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Aprodr models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASG24-09H220V1BAprodr · ASG Serieswith ductless indoor unit ASG24-09H220V1A | 1 ton9,000 Btu/h · Non-ducted | 82% | 2.33 | 13.0 | 8,200 | 24.6 | CEE 25CEE 26XcelES CC | 1 | 218035846 | Non-ducted, up to 1.5 tons | 85.9 |
| 2AHU3G-18HFN-BAprodr · AHU3G Serieswith ducted air handler AHU3G-18HFN-A | 1.5 tons18,000 Btu/h · Ducted | 103% | 2.12 | 10.1 | 18,600 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218045630 | Ducted, up to 1.5 tons | 85.5 |
| 3ALC24-09H1BAprodr · ALC Serieswith ducted air handler DIU-09HWFN10 | 1 ton9,000 Btu/h · Ducted | 83% | 2.32 | 11.5 | 8,300 | 19.7 | CEE 25CEE 26XcelES CC | 3 | 218035850 | Ducted, up to 1.5 tons | 81.3 |
| 4ALC24-09H1BAprodr · ALC Serieswith ductless indoor unit CCA22-09HRFN1 | 1 ton9,000 Btu/h · Non-ducted | 83% | 2.17 | 11.3 | 8,300 | 21.6 | CEE 25CEE 26XcelES CC | 3 | 218035855 | Non-ducted, up to 1.5 tons | 80.3 |
| 5AM6OG-48HFN1Aprodr · AM Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 38,000 | 20.4 | CEE 25CEE 26XcelES CC | 3 | 217334325 | Ducted, 3.5–4.5 tons | 77.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASG24-09H220V1BAprodr · ASG Serieswith ductless indoor unit ASG24-09H220V1A | 1 ton9,000 Btu/h · Non-ducted | 82% | 2.33 | 13.0 | 24.6 | 14.7 | CEE 25CEE 26XcelES CC | 1 | 218035846 | Non-ducted, up to 1.5 tons | 86.7 | 85.9 | 87.4 | 85.9 |
| 2AM6OG-48HFN1Aprodr · AM Series | 4 tons45,000 Btu/h · Ducted | 81% | 2.10 | 10.6 | 20.4 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217334325 | Ducted, 3.5–4.5 tons | 85.1 | 77.9 | 92.3 | 77.9 |
| 3ALC24-09H1BAprodr · ALC Serieswith ducted air handler DIU-09HWFN10 | 1 ton9,000 Btu/h · Ducted | 83% | 2.32 | 11.5 | 19.7 | 13.0 | CEE 25CEE 26XcelES CC | 3 | 218035850 | Ducted, up to 1.5 tons | 80.8 | 81.3 | 80.2 | 81.3 |
| 4AHU3G-18HFN-BAprodr · AHU3G Serieswith ducted air handler AHU3G-18HFN-A | 1.5 tons18,000 Btu/h · Ducted | 103% | 2.12 | 10.1 | 19.0 | 12.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 2 | 218045630 | Ducted, up to 1.5 tons | 79.3 | 85.5 | 73.1 | 85.5 |
| 5ASG24-09H1BAprodr · ASG Serieswith ductless indoor unit ASG24-09H1A | 1 ton9,000 Btu/h · Non-ducted | 73% | 2.21 | 10.7 | 24.5 | 15.0 | CEE 25CEE 26XcelES CC | 1 | 218035844 | Non-ducted, up to 1.5 tons | 78.9 | 69.8 | 88.0 | 69.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ALC24-12H1B | 2.51 | Non-ducted, up to 1.5 tons | 99% | 218035861 |
| Capacity retention at 5°F | AHU3G-18HFN-B | 103% | Ducted, up to 1.5 tons | 95% | 218045630 |
| HSPF2 | AHU3G-30HFN-B | 10.8 | Ducted, 2.5–3 tons | 98% | 218045634 |
| SEER2 | AM6OG-48HFN1 | 20.4 | Ducted, 3.5–4.5 tons | 96% | 217334325 |
| EER2 | ASG24-09H1B | 15.0 | Non-ducted, up to 1.5 tons | 91% | 218035844 |
| Heating capacity at 5°F | AHU3G-60HFN-B | 54,000 Btu/h | Ducted, 3.5–4.5 tons | 98% | 218045638 |
Aprodr size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.5(50 is the typical model of its size class)AHU3G-18HFN-Bwith ducted air handler AHU3G-18HFN-A5 of 6 models qualify · AHRI 218045630 | 80.8(50 is the typical model of its size class)ALC24-09H1Bwith ducted air handler DIU-09HWFN106 of 6 models have all five ratings · AHRI 218035850 |
| Ducted, 2 tons | 77.1(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models qualify · AHRI 218035853 | 78.8(50 is the typical model of its size class)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models have all five ratings · AHRI 218035853 |
| Ducted, 2.5–3 tons | 77.4(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A4 of 6 models qualify · AHRI 218045636 | 74.9(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A6 of 6 models have all five ratings · AHRI 218045636 |
| Ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class)AM6OG-48HFN16 of 6 models qualify · AHRI 217334325 | 85.1(50 is the typical model of its size class)AM6OG-48HFN16 of 6 models have all five ratings · AHRI 217334325 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 65.3(50 is the typical model of its size class)ALC24-60H1Bwith ducted air handler DIU-60HWFN102 of 2 models have all five ratings · AHRI 218035870 |
| Non-ducted, up to 1.5 tons | 85.9(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A15 of 19 models qualify · AHRI 218035846 | 86.7(50 is the typical model of its size class)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A19 of 19 models have all five ratings · AHRI 218035846 |
| Non-ducted, 2 tons | 73.7(50 is the typical model of its size class)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models qualify · AHRI 218035858 | 74.3(50 is the typical model of its size class)ASG24-24H1Bwith ductless indoor unit ASG24-24H1A5 of 5 models have all five ratings · AHRI 218035849 |
| Non-ducted, 2.5–3 tons | 62.8(50 is the typical model of its size class)ALC24-36H1Bwith ductless indoor unit CCA22-36HRFN12 of 4 models qualify · AHRI 218035859 | 58.3(50 is the typical model of its size class)AM5OG-36HFN14 of 4 models have all five ratings · AHRI 217334321 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models qualify · AHRI 217334326 | 52.8(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models have all five ratings · AHRI 217334326 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 32.5(50 is the typical model of its size class)AM6OG-55HFN11 of 1 models have all five ratings · AHRI 217334327 |
Newest Aprodr certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ALC24-18H1BAprodr · ALC Serieswith ductless indoor unit OWC-18HRFN10 | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.25 | 73% | 12.2 | 22.2 | CEE 25CEE 26XcelES CC | 3 | 218620811 |
| ALC24-12H1BAprodr · ALC Serieswith ductless indoor unit OWC-12HRFN10 | 1 ton12,000 Btu/h · Ducted and non-ducted | 2.47 | 72% | 10.0 | 22.1 | CEE 25CEE 26XcelES CC | 4 | 218620810 |
| ALC24-09H1BAprodr · ALC Serieswith ductless indoor unit OWC-09HRFN10 | 1 ton9,000 Btu/h · Ducted and non-ducted | 2.17 | 73% | 11.8 | 22.1 | CEE 25CEE 26XcelES CC | 3 | 218620809 |
| AHU3G-60HFN-BAprodr · AHU3G Serieswith ducted air handler AHU3G-60HFN-A | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | CEE 25CEE 26XcelES CC | 1 | 218045638 |
| AHU3G-48HFN-BAprodr · AHU3G Serieswith ducted air handler AHU3G-48HFN-A | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 9.5 | 17.5 | CEE 25CEE 26XcelES CC | 1 | 218045637 |
Compare Aprodr
Aprodr includes these brand names as listed in AHRI: Aprodr. Standards are checked against published thresholds; program rules beyond ratings are not checked.