Both views use the same certified data. This device remembers your choice.
Midea heat pump efficiency: 555 outdoor models compared
Midea has 555 heat pump outdoor models certified with this refrigerant group, in 6,788 AHRI-certified combinations. They are also sold as CTMorley, MDV. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Midea makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 555
- AHRI certifications
- 6,788
- Efficiency index
- 60%
- Typical model vs same-size, same-type peers (783 models)
- Meet CEE 2025
- 75.3%
- 418 models
How Midea compares with comparable models
- Midea
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index783 models scored | 60% | 7th of 29 | — |
| COP at 5°F786 models scored | 60% | 8th of 29 | 2.00 |
| Capacity retention at 5°F787 models scored | 57% | 10th of 29 | 74% |
| HSPF2796 models scored | 66% | 6th of 29 | 9.5 |
| SEER2799 models scored | 61% | 5th of 29 | 19.5 |
| EER2799 models scored | 55% | 13th of 29 | 11.7 |
| Heating capacity at 5°F787 models scored | 60% | 10th of 29 | 20,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 75.3% | 418 |
| CEE 2026 Tier 1 (Split ASHP) | 74.2% | 412 |
| CEE Advanced Tier (Split ASHP) | 3.4% | 19 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 69.7% | 387 |
| DOE Cold Climate Heat Pump Challenge | 3.4% | 19 |
| ENERGY STAR Cold Climate | 64% | 355 |
Sizes and duct types offered
- Midea (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 80 | 75% | 76% | 80% | 78% |
| Ducted, 2 tons | 57 | 62% | 53% | 69% | 70% |
| Ducted, 2.5 to 3 tons | 122 | 61% | 56% | 73% | 66% |
| Ducted, 3.5 to 4.5 tons | 110 | 63% | 53% | 75% | 66% |
| Ducted, 5 tons and up | 22 | 63% | 66% | 85% | 83% |
| Non-ducted, up to 1.5 tons | 185 | 57% | 66% | 60% | 56% |
| Non-ducted, 2 tons | 50 | 53% | 64% | 50% | 49% |
| Non-ducted, 2.5 to 3 tons | 94 | 56% | 52% | 58% | 56% |
| Non-ducted, 3.5 to 4.5 tons | 64 | 49% | 52% | 58% | 44% |
| Non-ducted, 5 tons and up | 15 | 45% | 51% | 50% | 49% |
Every Midea model in the market
- Midea models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Midea in the cold
- All listed models (median, middle 50% and 80%)
- Midea (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Midea, 47°F | 502 | 100% | 100% | 100% | 100% | 100% |
| Midea, 17°F | 502 | 64% | 68% | 73% | 81% | 85% |
| Midea, 5°F | 502 | 57% | 62% | 66% | 77% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Midea, 47°F | 502 | 2.88 | 3.1 | 3.24 | 3.49 | 3.61 |
| Midea, 17°F | 502 | 2.1 | 2.22 | 2.3 | 2.49 | 2.62 |
| Midea, 5°F | 502 | 1.85 | 1.99 | 2 | 2.11 | 2.31 |
Source: NEEP ccASHP list · as of
Top Midea models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOX230-06HFN10-M1MDV · MSEPBwith ductless indoor unit MSEPB-06HRFN10-M1 | 0.5 tons6,000 Btu/h · Non-ducted | 138% | 2.41 | 12.5 | 8,300 | 25.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215865890 | Non-ducted, up to 1.5 tons | 97.7 |
| 2D5CPRAH18AAMIDEA · D5F Serieswith ductless indoor unit D5FPHAH18XAKAlso sold as MDV MOD30-18HFN10-M1H | 1.5 tons18,000 Btu/h · Non-ducted | 113% | 2.34 | 15.2 | 22,600 | 24.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215413298 | Non-ducted, up to 1.5 tons | 97.1 |
| 337MAHAQ06AA3MIDEA · D5M Serieswith ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215323786 | Non-ducted, up to 1.5 tons | 97.0 |
| 4MO1HS-H06B-2AMIDEA · MSE Serieswith ductless indoor unit MSEHU-H06B-2A | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215471379 | Non-ducted, up to 1.5 tons | 97.0 |
| 5MOU-B06H-2CTMorleywith ductless indoor unit MIU-B06CO-2 | 0.5 tons6,500 Btu/h · Non-ducted | 109% | 2.40 | 12.0 | 8,100 | 22.0 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217022096 | Non-ducted, up to 1.5 tons | 94.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 137MAHAQ06AA3MIDEA · D5M Serieswith ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.7 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215323786 | Non-ducted, up to 1.5 tons | 96.9 | 97.0 | 96.7 | 97.0 |
| 2MO1HS-H06B-2AMIDEA · MSE Serieswith ductless indoor unit MSEHU-H06B-2A | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 215471379 | Non-ducted, up to 1.5 tons | 96.6 | 97.0 | 96.1 | 97.0 |
| 3MOX230-06HFN10-M1MDV · MSEPBwith ductless indoor unit MSEPB-06HRFN10-M1 | 0.5 tons6,000 Btu/h · Non-ducted | 138% | 2.41 | 12.5 | 25.0 | 18.1 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 215865890 | Non-ducted, up to 1.5 tons | 96.1 | 97.7 | 94.6 | 97.7 |
| 437MAHAQ06AA3MIDEA · 45M Serieswith ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.5 | 14.5 | CEE 25CEE 26XcelES CC | 3 | 215324042 | Ducted, up to 1.5 tons | 95.7 | 93.7 | 97.7 | 93.7 |
| 5MO1HS-H06B-2AMIDEA · MDL Serieswith ducted air handler MDLHU-H06B-2A | 0.5 tons6,500 Btu/h · Ducted | 98% | 2.41 | 13.8 | 21.4 | 14.4 | CEE 25CEE 26XcelES CC | 3 | 215471411 | Ducted, up to 1.5 tons | 95.1 | 93.7 | 96.5 | 93.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 37MARAQ12AA3Also sold as MDV MOX230-12HFN10-M1; also listed as D5CSRAH12AAK | 2.51 | Non-ducted, up to 1.5 tons | 99% | 215324068 |
| Capacity retention at 5°F | 37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1H | 150% | Non-ducted, up to 1.5 tons | 100% | 215413165 |
| HSPF2 | 37MPRAQ06AA3Also sold as MDV MOX430-06HFN10-M1H | 15.6 | Non-ducted, up to 1.5 tons | 100% | 215413165 |
| SEER2 | MOX430-15HFN10-M1H | 27.0 | Ducted, up to 1.5 tons | 100% | 217998294 |
| EER2 | MOX230-06HFN10-M1 | 18.1 | Non-ducted, up to 1.5 tons | 100% | 215865890 |
| Heating capacity at 5°F | MOVA-60HDN10-M20GAlso listed as MOVC-60HDN10-M20G | 55,000 Btu/h | Ducted, 3.5 to 4.5 tons | 100% | 214814477 |
Midea size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK71 of 81 models qualify · AHRI 215324042 | 95.7(50 is the typical model of its size class)37MAHAQ06AA3with ducted air handler 45MBDAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK83 of 83 models have all five ratings · AHRI 215324042 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)37MAHAQ24AA3with ducted air handler 45MBDAQ24XH3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK49 of 54 models qualify · AHRI 215324061 | 90.0(50 is the typical model of its size class)MOD30-24HFN10-M1Hwith ducted air handler MSEPD-24HRFN10-M1H55 of 55 models have all five ratings · AHRI 217998293 |
| Ducted, 2.5 to 3 tons | 90.3(50 is the typical model of its size class)M4OD31-27HFN8-M1XD92 of 126 models qualify · AHRI 218083250 | 91.8(50 is the typical model of its size class)M4OD31-27HFN8-M1XD121 of 121 models have all five ratings · AHRI 218083250 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)MOVA-60HDN10-M20Gwith ducted air handler MVME60C2MN10TAAlso listed as MOVC-60HDN10-M20G91 of 106 models qualify · AHRI 214814477 | 86.0(50 is the typical model of its size class)D5CMRAH48FAKAlso sold as MDV M6OE30-48HFN10-M1D, MDV M6OE30-48HFN10-M1; also listed as 37MGRAQ48FA3110 of 110 models have all five ratings · AHRI 215357445 |
| Ducted, 5 tons and up | 67.0(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)6 of 24 models qualify · AHRI 216021062 | 70.5(50 is the typical model of its size class)MRD-60HWD1N10-M18GAlso listed as MRD-60HWD1N10-M18GB22 of 22 models have all five ratings · AHRI 215894250 |
| Non-ducted, up to 1.5 tons | 97.7(50 is the typical model of its size class)MOX230-06HFN10-M1with ductless indoor unit MSEPB-06HRFN10-M1125 of 185 models qualify · AHRI 215865890 | 96.9(50 is the typical model of its size class)37MAHAQ06AA3with ductless indoor unit D5MAHAQ06XA3Also sold as MDV MOX230-06HFN10-M1X; also listed as D5CSHAH06AAK176 of 185 models have all five ratings · AHRI 215323786 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)37MAHAQ24AA3with ductless indoor unit 45MBCAQ24XA3Also sold as MDV MOD30-24HFN10-M1X; also listed as D5CSHAH24AAK44 of 50 models qualify · AHRI 215324059 | 89.4(50 is the typical model of its size class)37MARAQ24AA3with ductless indoor unit D5MAHAQ24XA3Also sold as MDV MOD30-24HFN10-M1; also listed as D5CSRAH24AAK46 of 50 models have all five ratings · AHRI 215323796 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)37MBHAQ36AA3with ductless indoor unit 45MCFAQ36XA3Also sold as MDV MOX630-36HFN10-M2X; also listed as D5CLHAH36AAK78 of 94 models qualify · AHRI 215324087 | 89.4(50 is the typical model of its size class)M4OD31-27HFN8-M1XD93 of 94 models have all five ratings · AHRI 218083249 |
| Non-ducted, 3.5 to 4.5 tons | 75.6(50 is the typical model of its size class)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA357 of 64 models qualify · AHRI 215357417 | 76.6(50 is the typical model of its size class)D5CMHAH48FAKAlso sold as MDV M6OE31-48HFN10-M1XD, MDV M6OE31-48HFN10-M1X; also listed as 37MGHAQ48FA363 of 64 models have all five ratings · AHRI 215357415 |
| Non-ducted, 5 tons and up | 52.1(50 is the typical model of its size class)MDV-V60WMN10TAlso listed as MDV-V60WMN10T(B)3 of 15 models qualify · AHRI 216021081 | 61.8(50 is the typical model of its size class)D5CMRAH55FAKAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1; also listed as 37MGRAQ55FA315 of 15 models have all five ratings · AHRI 215357450 |
Newest Midea certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MOVC-48HN10-M152LMIDEAwith ducted air handler V3642B-*EC*E**1 | 3 tons38,500 Btu/h · Ducted | 1.86 | 53% | 6.8 | 12.0 | None | 45 | 219137152 |
| MOVC-42HN10-M152LMIDEAwith ducted air handler V3642B-*EC*E**1 | 3 tons35,200 Btu/h · Ducted | 1.86 | 53% | 6.8 | 12.0 | None | 72 | 219137149 |
| MOVC-36HN10-M152LMIDEAwith ducted air handler V3642B-*EC*B**1 | 2.5 tons30,000 Btu/h · Ducted | 1.78 | 52% | 6.8 | 12.0 | None | 72 | 219137146 |
| MOVC-30HN10-M152LMIDEAwith ducted air handler V2430B-*EC*E**1 | 2 tons24,200 Btu/h · Ducted | 1.74 | 48% | 6.8 | 12.0 | None | 124 | 219137142 |
| MOVC-24HN10-M152LMIDEAwith ducted air handler V2430B-*EC*E**1 | 1.5 tons18,700 Btu/h · Ducted | 1.62 | 49% | 6.8 | 12.0 | None | 104 | 219137135 |
Compare Midea
Midea includes these brand names as listed in AHRI: CTMorley, MDV, MIDEA. Standards are checked against published thresholds; program rules beyond ratings are not checked.