Skip to content

MRCOOL heat pump efficiency: 92 outdoor models compared

MRCOOL has 92 heat pump outdoor models certified with this refrigerant group, in 521 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MRCOOL makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
92
AHRI certifications
521
Efficiency index
54%
Typical model vs same-size, same-type peers (103 models)
Meet CEE 2025
67.4%
62 models

How MRCOOL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
MRCOOL against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of MRCOOL’s own modelsMRCOOL is strongest on HSPF2 (its typical model beats 57% of comparable models) and weakest on COP at 5°F (50%).
  • MRCOOL
  • Middle half of its models
  • Other ranked manufacturers
MRCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile of MRCOOL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index103 models scored54%15th of 29—
COP at 5°F103 models scored50%19th of 291.99
Capacity retention at 5°F103 models scored51%16th of 2973%
HSPF2110 models scored57%11th of 299.2
SEER2110 models scored55%15th of 2918.8
EER2110 models scored51%17th of 2911.7
Heating capacity at 5°F103 models scored53%15th of 2917,100 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
MRCOOL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • MRCOOL (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1068%56%68%68%
Ducted, 2 tons1257%50%61%59%
Ducted, 2.5 to 3 tons1552%43%58%51%
Ducted, 3.5 to 4.5 tons1955%42%55%52%
Non-ducted, up to 1.5 tons3553%54%61%55%
Non-ducted, 2 tons1049%64%47%46%
Non-ducted, 2.5 to 3 tons635%37%27%48%
Non-ducted, 3.5 to 4.5 tons361%47%60%72%

Every MRCOOL model in the market

MRCOOL’s 110 models with a known size and duct type, over the shape of the whole catalog.
MRCOOL models by size and ratingColoured: MRCOOL · grey shapes: all 15,936 models · lines: catalog medians by size
  • MRCOOL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 110 mrcool models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

MRCOOL in the cold

From NEEP’s cold-climate listings: 77 MRCOOL models against all 6,343 listed models.
MRCOOL capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical MRCOOL model keeps 68% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • MRCOOL (median, middle 50%)
Heating capacity, % of its 47°F maximum68%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
MRCOOL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
MRCOOL, 47°F77100%100%100%100%100%
MRCOOL, 17°F7760%67%73%86%94%
MRCOOL, 5°F7757%59%68%80%86%
MRCOOL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
MRCOOL, 47°F772.7733.193.393.59
MRCOOL, 17°F771.972.132.292.392.52
MRCOOL, 5°F771.81.922.092.18

Source: NEEP ccASHP list · as of

Top MRCOOL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 MRCOOL cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1O-ES-24-HP-C-230C-O1MRCOOLwith ductless indoor unit O-18-HP-WMAH-233C-O2 tons24,000 Btu/h · Non-ducted83%2.3413.524,20021.0CEE 25CEE 26XcelES CC4217447810Non-ducted, 2 tons90.3
2O-HH-24-HP-C-230C-OMRCOOL · O-HH Serieswith ductless indoor unit CASSETTE24HP-230C-O2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC3216032567Non-ducted, 2 tons90.1
3O-ES-24-HP-C-230C-O1MRCOOLwith ducted air handler O-18-HP-WMAH-235C-O2 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26Xcel4217447812Ducted, 2 tons86.5
4O-HH-24-HP-C-230C-OMRCOOL · O-HH Serieswith ducted air handler DUCT-24HP-230B-O2 tons24,000 Btu/h · Ducted92%2.1811.724,00019.0CEE 25CEE 26XcelES CC3216032568Ducted, 2 tons85.8
5DIYHH-12-HP-C-230D25-OMRCOOL · DIY Serieswith ductless indoor unit DIYCASSETTE12HP-230D25-O1 ton12,000 Btu/h · Non-ducted92%2.1110.811,50022.2CEE 25CEE 26XcelES CC2216032550Non-ducted, up to 1.5 tons81.6

All-around best

Top 5 MRCOOL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1O-HH-09-HP-C-230C-OMRCOOL · O-HH Serieswith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O11 ton9,000 Btu/h · Ducted112%1.8912.521.413.4CEE 25CEE 26XcelES CC3216032559Ducted, up to 1.5 tons87.180.693.680.6
2MULTI6-48HP230C-OMRCOOL · MULTI Series4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26XcelES CC3217291702Ducted, 3.5 to 4.5 tons85.378.192.678.1
3DIY-MULTI6-55HP230D-OMRCOOL · DIY Series4 tons47,000 Btu/h · Ducted84%2.0010.520.012.0CEE 25CEE 26XcelES CC3216032599Ducted, 3.5 to 4.5 tons82.073.590.473.5
4O-HH-09-HP-C-230C-OMRCOOL · O-HH Serieswith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O11 ton9,000 Btu/h · Non-ducted96%1.8012.527.415.4CEE 25CEE 26XcelES CC3216032557Non-ducted, up to 1.5 tons81.366.196.574.2
5DIY-MULTI6-48HP230D-OMRCOOL · DIY Series3.5 tons43,000 Btu/h · Ducted79%2.0010.520.012.0CEE 25CEE 26XcelES CC3216032596Ducted, 3.5 to 4.5 tons80.670.890.470.8

Best model on each rating

MRCOOL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDIY-18-HP-C-230D25-OAlso listed as DIYP-18-HP-C-230DE11-O2.44Non-ducted, up to 1.5 tons98%216032545
Capacity retention at 5°FO-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1112%Ducted, up to 1.5 tons97%216032559
HSPF2O-HH-24-HP-C-230C-O13.5Non-ducted, 2 tons98%216032566
SEER2MULTI4-27HP230C-O25.0Non-ducted, 2.5 to 3 tons97%217291695
EER2O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O115.4Non-ducted, up to 1.5 tons95%216032557
Heating capacity at 5°FCENTRAL-36-HP-C-230B00-O39,000 Btu/hDucted, 2.5 to 3 tons98%216032532

All 92 MRCOOL models in Explore

MRCOOL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
MRCOOL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons80.6(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O18 of 10 models qualify · AHRI 21603255987.1(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O19 of 10 models have all five ratings · AHRI 216032559
Ducted, 2 tons86.5(50 is the typical model of its size class)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O9 of 12 models qualify · AHRI 21744781278.9(50 is the typical model of its size class)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O10 of 12 models have all five ratings · AHRI 217447812
Ducted, 2.5 to 3 tons77.2(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O9 of 15 models qualify · AHRI 21773032973.5(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O13 of 15 models have all five ratings · AHRI 217730329
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)MULTI6-48HP230C-O12 of 19 models qualify · AHRI 21729170285.3(50 is the typical model of its size class)MULTI6-48HP230C-O15 of 19 models have all five ratings · AHRI 217291702
Non-ducted, up to 1.5 tons81.6(50 is the typical model of its size class)DIYHH-12-HP-C-230D25-Owith ductless indoor unit DIYCASSETTE12HP-230D25-O22 of 35 models qualify · AHRI 21603255081.3(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O135 of 35 models have all five ratings · AHRI 216032557
Non-ducted, 2 tons90.3(50 is the typical model of its size class)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O6 of 10 models qualify · AHRI 21744781078.7(50 is the typical model of its size class)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O10 of 10 models have all five ratings · AHRI 217447810
Non-ducted, 2.5 to 3 tons42.4(50 is the typical model of its size class)DIY-MULTI5-36HP230D-O3 of 6 models qualify · AHRI 21603259266.9(50 is the typical model of its size class)MULTI4-27HP230C-O6 of 6 models have all five ratings · AHRI 217291695
Non-ducted, 3.5 to 4.5 tons56.7(50 is the typical model of its size class)MULTI6-48HP230C-O3 of 3 models qualify · AHRI 21729170368.7(50 is the typical model of its size class)MULTI6-48HP230C-O3 of 3 models have all five ratings · AHRI 217291703

All-around board, every manufacturer

Newest MRCOOL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified MRCOOL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
MVP-60-HP-C-230A00-OMRCOOLwith ducted air handler MCMP4860DOTB4 tons50,000 Btu/h · Ducted1.8078%8.214.3ES CC15219136293
MVP-48-HP-C-230A00-OMRCOOLwith ducted air handler MCMP4860DOTB4 tons45,000 Btu/h · Ducted1.7581%8.014.8CEE 25CEE 26XcelES CC17219136292
CENTRAL-60-HP-C-230B00-OMRCOOL · CEN Serieswith ducted air handler MCMP4860DOTB4 tons47,000 Btu/h · Ducted1.8374%8.115.2CEE 25CEE 26XcelES CC17219136291
CENTRAL-48-HP-C-230B00-OMRCOOLwith ducted air handler MCMP4860DOTB4 tons45,000 Btu/h · Ducted1.8085%8.414.5CEE 25CEE 26XcelES CC19219136290
MVP-36-HP-C-230A00-OMRCOOL · MVP Serieswith ducted air handler MCMP3036BOTB3 tons36,000 Btu/h · Ducted2.0076%8.514.7CEE 25CEE 26XcelES CC18219136285

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare MRCOOL

Manufacturers of a similar size, side by side.

MRCOOL includes these brand names as listed in AHRI: MRCOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter