Skip to content

Della vs MRCOOL heat pumps

Measured against models of the same size and duct type, MRCOOL scores higher on 5 of the 6 ratings. Della has 97 outdoor models, MRCOOL has 92 outdoor models. They share hardware: 4 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Della and MRCOOL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MRCOOL scores higher on 5 of the 6 ratings.
  • Della
  • MRCOOL
  • Other ranked manufacturers
DellaMRCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDellaMRCOOL
Efficiency index49%median — · 22nd ranked54%median — · 15th ranked
COP at 5°F43%median 1.90 · 26th ranked50%median 1.99 · 19th ranked
Capacity retention at 5°F46%median 73% · 21st ranked51%median 73% · 16th ranked
HSPF251%median 9.5 · 15th ranked57%median 9.2 · 11th ranked
SEER257% (higher)median 21.0 · 11th ranked55% (higher)median 18.8 · 15th ranked
EER242%median 11.2 · 23rd ranked51%median 11.7 · 17th ranked
Heating capacity at 5°F47%median 12,000 Btu/h · 21st ranked53%median 17,100 Btu/h · 15th ranked
Outdoor models9792
AHRI certifications149521

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDellaMRCOOL
CEE 2025 Tier 1 (Split ASHP)68%66 models67.4%62 models
CEE 2026 Tier 1 (Split ASHP)68%66 models66.3%61 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)66%64 models57.6%53 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate42.3%41 models56.5%52 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Della
  • MRCOOL
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDellaMRCOOL
Ducted, up to 1.5 tons6 · index 59%10 · index 68%
Ducted, 2 tons3 · index 49%12 · index 57%
Ducted, 2.5 to 3 tons6 · index 62%15 · index 52%
Ducted, 3.5 to 4.5 tons6 · index 54%19 · index 55%
Non-ducted, up to 1.5 tons63 · index 48%35 · index 53%
Non-ducted, 2 tons13 · index 48%10 · index 49%
Non-ducted, 2.5 to 3 tons12 · index 43%6 · index 35%
Non-ducted, 3.5 to 4.5 tons5 · index 44%3 · index 61%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDellaCold-climate score, best modelMRCOOLCold-climate score, best model
Ducted, up to 1.5 tons59.9(50 is the typical model of its size class)048-TP-9K2V-24S-OUT6 of 6 models qualify · AHRI 21808283380.6(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O18 of 10 models qualify · AHRI 216032559
Ducted, 2 tons60.1(50 is the typical model of its size class)048-TP-23K2V-23S-OUT3 of 3 models qualify · AHRI 21808283686.5(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O9 of 12 models qualify · AHRI 217447812
Ducted, 2.5 to 3 tons63.0(50 is the typical model of its size class)048-TPH-MODU-1D46 of 6 models qualify · AHRI 21871874077.2(50 is the typical model of its size class) (higher)UHP18030-Owith ducted air handler UAH18030 - O9 of 15 models qualify · AHRI 217730329
Ducted, 3.5 to 4.5 tons63.7(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models qualify · AHRI 21871873878.1(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O12 of 19 models qualify · AHRI 217291702
Non-ducted, up to 1.5 tons72.4(50 is the typical model of its size class)048-TPH-MODU-1D344 of 63 models qualify · AHRI 21847100781.6(50 is the typical model of its size class) (higher)DIYHH-12-HP-C-230D25-Owith ductless indoor unit DIYCASSETTE12HP-230D25-O22 of 35 models qualify · AHRI 216032550
Non-ducted, 2 tons78.6(50 is the typical model of its size class)048-MS-24K2VR-22S-M-OUTwith ductless indoor unit 048-MS-24K2VR-22S-M-INAlso listed as 048-MS-24K2VR-22S-MX-OUT6 of 13 models qualify · AHRI 21676002290.3(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O6 of 10 models qualify · AHRI 217447810
Non-ducted, 2.5 to 3 tons68.7(50 is the typical model of its size class) (higher)048-TPH-MODU-1D48 of 12 models qualify · AHRI 21847100842.4(50 is the typical model of its size class)DIY-MULTI5-36HP230D-O3 of 6 models qualify · AHRI 216032592
Non-ducted, 3.5 to 4.5 tons48.5(50 is the typical model of its size class)048-TPH-MODU-1D64 of 5 models qualify · AHRI 21847101056.7(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models qualify · AHRI 217291703

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDellaAll-around score, best modelMRCOOLAll-around score, best model
Ducted, up to 1.5 tons73.5(50 is the typical model of its size class)048-TPH-MODU-1D36 of 6 models have all five ratings · AHRI 21871873987.1(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O19 of 10 models have all five ratings · AHRI 216032559
Ducted, 2 tons55.8(50 is the typical model of its size class)048-TP-23K2V-23S-OUT3 of 3 models have all five ratings · AHRI 21808283678.9(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O10 of 12 models have all five ratings · AHRI 217447812
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class) (higher)048-TPH-MODU-1D46 of 6 models have all five ratings · AHRI 21871874073.5(50 is the typical model of its size class)UHP18030-Owith ducted air handler UAH18030 - O13 of 15 models have all five ratings · AHRI 217730329
Ducted, 3.5 to 4.5 tons66.2(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models have all five ratings · AHRI 21871873885.3(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O15 of 19 models have all five ratings · AHRI 217291702
Non-ducted, up to 1.5 tons83.7(50 is the typical model of its size class) (higher)048-TPH-MODU-1D357 of 63 models have all five ratings · AHRI 21847100781.3(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O135 of 35 models have all five ratings · AHRI 216032557
Non-ducted, 2 tons70.2(50 is the typical model of its size class)048-MS-24K2VR-22S-M-OUTwith ductless indoor unit 048-MS-24K2VR-22S-M-INAlso listed as 048-MS-24K2VR-22S-MX-OUT12 of 13 models have all five ratings · AHRI 21676002278.7(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O10 of 10 models have all five ratings · AHRI 217447810
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)048-TPH-MODU-1D412 of 12 models have all five ratings · AHRI 21847100866.9(50 is the typical model of its size class)MULTI4-27HP230C-O6 of 6 models have all five ratings · AHRI 217291695
Non-ducted, 3.5 to 4.5 tons70.2(50 is the typical model of its size class) (higher)048-TPH-MODU-1D65 of 5 models have all five ratings · AHRI 21847101068.7(50 is the typical model of its size class)MULTI6-48HP230C-O3 of 3 models have all five ratings · AHRI 217291703

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDellaMRCOOL
COP at 5°Fbeats 88% · 2.27048-MS-24K2VR-21S-OUTNon-ducted, 2 tonsbeats 98% · 2.44DIY-18-HP-C-230D25-OAlso listed as DIYP-18-HP-C-230DE11-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 96% · 105%048-TPH-MODU-1D3Ducted, up to 1.5 tonsbeats 97% · 112%O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Ducted, up to 1.5 tons
HSPF2beats 96% · 10.5048-TLP-MODU-1D4Ducted, 2.5 to 3 tonsbeats 98% · 13.5O-HH-24-HP-C-230C-ONon-ducted, 2 tons
SEER2beats 100% · 22.0048-TPH-MODU-1D4Ducted, 2.5 to 3 tonsbeats 97% · 25.0MULTI4-27HP230C-ONon-ducted, 2.5 to 3 tons
EER2beats 97% · 14.0048-TPH-MODU-1D4Non-ducted, 2.5 to 3 tonsbeats 95% · 15.4O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 19,800 Btu/h048-TPH-MODU-1D3Non-ducted, up to 1.5 tonsbeats 98% · 39,000 Btu/hCENTRAL-36-HP-C-230B00-ODucted, 2.5 to 3 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter