Skip to content

Bestcold vs MRCOOL heat pumps

Measured against models of the same size and duct type, MRCOOL scores higher on 6 of the 6 ratings. Bestcold has 96 outdoor models, MRCOOL has 92 outdoor models. Bestcold has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Bestcold and MRCOOL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MRCOOL scores higher on 6 of the 6 ratings.
  • Bestcold
  • MRCOOL
  • Other ranked manufacturers
BestcoldMRCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBestcoldMRCOOL
Efficiency index46%median —54%median — · 15th ranked
COP at 5°F43%median 1.8950%median 1.99 · 19th ranked
Capacity retention at 5°F46%median 72%51%median 73% · 16th ranked
HSPF247%median 9.057%median 9.2 · 11th ranked
SEER251%median 18.555%median 18.8 · 15th ranked
EER240%median 11.251%median 11.7 · 17th ranked
Heating capacity at 5°F48%median 18,900 Btu/h53%median 17,100 Btu/h · 15th ranked
Outdoor models9692
AHRI certifications108521

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBestcoldMRCOOL
CEE 2025 Tier 1 (Split ASHP)65.6%63 models67.4%62 models
CEE 2026 Tier 1 (Split ASHP)65.6%63 models66.3%61 models
CEE Advanced Tier (Split ASHP)1%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)62.5%60 models57.6%53 models
DOE Cold Climate Heat Pump Challenge1%1 models0%0 models
ENERGY STAR Cold Climate21.9%21 models56.5%52 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Bestcold
  • MRCOOL
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBestcoldMRCOOL
Ducted, up to 1.5 tons1 · index —10 · index 68%
Ducted, 2 tons11 · index 61%12 · index 57%
Ducted, 2.5 to 3 tons11 · index 46%15 · index 52%
Ducted, 3.5 to 4.5 tons22 · index 52%19 · index 55%
Non-ducted, up to 1.5 tons32 · index 44%35 · index 53%
Non-ducted, 2 tons7 · index 37%10 · index 49%
Non-ducted, 2.5 to 3 tons9 · index 35%6 · index 35%
Non-ducted, 3.5 to 4.5 tons3 · index 29%3 · index 61%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBestcoldCold-climate score, best modelMRCOOLCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)80.4(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O18 of 10 models qualify · AHRI 216032559
Ducted, 2 tons80.8(50 is the typical model of its size class)MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-I10 of 11 models qualify · AHRI 21789646386.5(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O9 of 12 models qualify · AHRI 217447812
Ducted, 2.5 to 3 tons70.1(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I7 of 11 models qualify · AHRI 21789646077.2(50 is the typical model of its size class) (higher)UHP18030-Owith ducted air handler UAH18030 - O9 of 15 models qualify · AHRI 217730329
Ducted, 3.5 to 4.5 tons76.9(50 is the typical model of its size class)MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-I17 of 22 models qualify · AHRI 21789646578.1(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O12 of 19 models qualify · AHRI 217291702
Non-ducted, up to 1.5 tons70.1(50 is the typical model of its size class)MYTW18NA23BCH24-O22 of 32 models qualify · AHRI 21859934681.6(50 is the typical model of its size class) (higher)DIYHH-12-HP-C-230D25-Owith ductless indoor unit DIYCASSETTE12HP-230D25-O22 of 35 models qualify · AHRI 216032550
Non-ducted, 2 tons59.1(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I3 of 7 models qualify · AHRI 21807845390.3(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O6 of 10 models qualify · AHRI 217447810
Non-ducted, 2.5 to 3 tons58.2(50 is the typical model of its size class) (higher)MYTW27NA23BCH24-O6 of 9 models qualify · AHRI 21859934742.4(50 is the typical model of its size class)DIY-MULTI5-36HP230D-O3 of 6 models qualify · AHRI 216032592
Non-ducted, 3.5 to 4.5 tons31.5(50 is the typical model of its size class)MYTW42NA23BCH24-O2 of 3 models qualify · AHRI 21859934956.7(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models qualify · AHRI 217291703

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBestcoldAll-around score, best modelMRCOOLAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)87.0(50 is the typical model of its size class)O-HH-09-HP-C-230C-Owith ducted air handler DUCT-09HP-230B-OAlso listed as O-ES-09-HP-C-230C-O19 of 10 models have all five ratings · AHRI 216032559
Ducted, 2 tons79.5(50 is the typical model of its size class) (higher)MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-I10 of 11 models have all five ratings · AHRI 21760604978.9(50 is the typical model of its size class)O-ES-24-HP-C-230C-O1with ducted air handler O-18-HP-WMAH-235C-O10 of 12 models have all five ratings · AHRI 217447812
Ducted, 2.5 to 3 tons66.2(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I9 of 11 models have all five ratings · AHRI 21789646073.5(50 is the typical model of its size class) (higher)UHP18030-Owith ducted air handler UAH18030 - O13 of 15 models have all five ratings · AHRI 217730329
Ducted, 3.5 to 4.5 tons73.3(50 is the typical model of its size class)MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-I19 of 22 models have all five ratings · AHRI 21765058085.3(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O15 of 19 models have all five ratings · AHRI 217291702
Non-ducted, up to 1.5 tons77.3(50 is the typical model of its size class)MYTW09NA23BCH25ES-Owith ductless indoor unit MYTW09NA23BCH25ES-I32 of 32 models have all five ratings · AHRI 21807845081.3(50 is the typical model of its size class) (higher)O-HH-09-HP-C-230C-Owith ductless indoor unit O-09-HP-WMAH-230C-OAlso listed as O-ES-09-HP-C-230C-O135 of 35 models have all five ratings · AHRI 216032557
Non-ducted, 2 tons58.5(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I7 of 7 models have all five ratings · AHRI 21807845378.7(50 is the typical model of its size class) (higher)O-ES-24-HP-C-230C-O1with ductless indoor unit O-18-HP-WMAH-233C-O10 of 10 models have all five ratings · AHRI 217447810
Non-ducted, 2.5 to 3 tons65.9(50 is the typical model of its size class)MYTW27NA23BCH24-O9 of 9 models have all five ratings · AHRI 21859934766.9(50 is the typical model of its size class) (higher)MULTI4-27HP230C-O6 of 6 models have all five ratings · AHRI 217291695
Non-ducted, 3.5 to 4.5 tons42.3(50 is the typical model of its size class)MYTW42NA23BCH24-O3 of 3 models have all five ratings · AHRI 21859934968.7(50 is the typical model of its size class) (higher)MULTI6-48HP230C-O3 of 3 models have all five ratings · AHRI 217291703

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBestcoldMRCOOL
COP at 5°Fbeats 99% · 2.44MYMBW-36NA22BCH18-ONon-ducted, 2.5 to 3 tonsbeats 98% · 2.44DIY-18-HP-C-230D25-OAlso listed as DIYP-18-HP-C-230DE11-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 103%MYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tonsbeats 97% · 112%O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Ducted, up to 1.5 tons
HSPF2beats 84% · 9.8MYUA48NA23BCH19-ODucted, 3.5 to 4.5 tonsbeats 98% · 13.5O-HH-24-HP-C-230C-ONon-ducted, 2 tons
SEER2beats 90% · 24.0MYTW27NA23BCH24-ONon-ducted, 2.5 to 3 tonsbeats 97% · 25.0MULTI4-27HP230C-ONon-ducted, 2.5 to 3 tons
EER2beats 98% · 14.0MYUA24NA23BCH20-ODucted, 2 tonsbeats 95% · 15.4O-HH-09-HP-C-230C-OAlso listed as O-ES-09-HP-C-230C-O1Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 97% · 25,800 Btu/hMYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tonsbeats 98% · 39,000 Btu/hCENTRAL-36-HP-C-230B00-ODucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Bestcold vs MRCOOL: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Bestcold (median, middle 50%)
  • MRCOOL (median, middle 50%)
Heating capacity, % of its 47°F maximum66%68%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Bestcold: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Bestcold, 47°F49100%100%100%100%100%
Bestcold, 17°F4970%72%73%80%85%
Bestcold, 5°F4957%61%66%72%74%
Bestcold: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Bestcold, 47°F492.472.893.333.513.69
Bestcold, 17°F491.972.092.22.252.4
Bestcold, 5°F491.81.822.12.12
MRCOOL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
MRCOOL, 47°F77100%100%100%100%100%
MRCOOL, 17°F7760%67%73%86%94%
MRCOOL, 5°F7757%59%68%80%86%
MRCOOL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
MRCOOL, 47°F772.7733.193.393.59
MRCOOL, 17°F771.972.132.292.392.52
MRCOOL, 5°F771.81.922.092.18

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter