Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Bestcold and Puremind on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Bestcold scores higher on 5 of the 6 ratings.
  • Bestcold
  • Puremind
  • Other ranked manufacturers
BestcoldPuremind

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBestcoldPuremind
Efficiency index46% (higher)median —38% (higher)median —
COP at 5°F43% (higher)median 1.8924% (higher)median 1.80
Capacity retention at 5°F46% (higher)median 72%42% (higher)median 72%
HSPF247%median 9.052%median 9.5
SEER251% (higher)median 18.546% (higher)median 20.0
EER240% (higher)median 11.230% (higher)median 10.0
Heating capacity at 5°F48% (higher)median 18,900 Btu/h43% (higher)median 12,000 Btu/h
Outdoor models9695
AHRI certifications10895

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBestcoldPuremind
CEE 2025 Tier 1 (Split ASHP)65.6%63 models47.4%45 models
CEE 2026 Tier 1 (Split ASHP)65.6%63 models47.4%45 models
CEE Advanced Tier (Split ASHP)1%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)62.5%60 models52.6%50 models
DOE Cold Climate Heat Pump Challenge1%1 models0%0 models
ENERGY STAR Cold Climate21.9%21 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 6 groups where both have models
  • Bestcold
  • Puremind
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBestcoldPuremind
Ducted, up to 1.5 tons1 · index —None
Ducted, 2 tons11 · index 61%6 · index 30%
Ducted, 2.5 to 3 tons11 · index 46%6 · index 39%
Ducted, 3.5 to 4.5 tons22 · index 52%12 · index 35%
Non-ducted, up to 1.5 tons32 · index 44%52 · index 44%
Non-ducted, 2 tons7 · index 37%12 · index 36%
Non-ducted, 2.5 to 3 tons9 · index 35%7 · index 16%
Non-ducted, 3.5 to 4.5 tons3 · index 29%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBestcoldCold-climate score, best modelPuremindCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)No models in this size class
Ducted, 2 tons80.8(50 is the typical model of its size class) (higher)MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-I10 of 11 models qualify · AHRI 21789646342.0(50 is the typical model of its size class)PTF24B1-EBH4Uwith ducted air handler PTF24B1-EBH4UAlso listed as ATF24B1-EBH4U, CTF24B1-EBH4U3 of 6 models qualify · AHRI 218725507
Ducted, 2.5 to 3 tons70.1(50 is the typical model of its size class) (higher)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I7 of 11 models qualify · AHRI 21789646055.0(50 is the typical model of its size class)PTF36B1-EBH4Uwith ducted air handler PTF36B1-EBH4UAlso listed as ATF36B1-EBH4U, CTF36B1-EBH4U3 of 6 models qualify · AHRI 218725508
Ducted, 3.5 to 4.5 tons76.9(50 is the typical model of its size class) (higher)MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-I17 of 22 models qualify · AHRI 21789646544.5(50 is the typical model of its size class)PTF48B1-BBH4Uwith ducted air handler PTF48B1-BBH4UAlso listed as ATF48B1-BBH4U, CTF48B1-BBH4U12 of 12 models qualify · AHRI 218725521
Non-ducted, up to 1.5 tons70.1(50 is the typical model of its size class) (higher)MYTW18NA23BCH24-O22 of 32 models qualify · AHRI 21859934664.5(50 is the typical model of its size class)PTW09B1-EBH5D-04with ductless indoor unit PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-0439 of 52 models qualify · AHRI 218686859
Non-ducted, 2 tons59.1(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I3 of 7 models qualify · AHRI 21807845359.1(50 is the typical model of its size class)PTW24B1-EBH5D-04with ductless indoor unit PTW24B1-EBH5D-04Also listed as ATW24B1-EBH5D-045 of 12 models qualify · AHRI 218686862
Non-ducted, 2.5 to 3 tons58.2(50 is the typical model of its size class)MYTW27NA23BCH24-O6 of 9 models qualify · AHRI 218599347None on this board (0 of 7 models qualify)
Non-ducted, 3.5 to 4.5 tons31.5(50 is the typical model of its size class)MYTW42NA23BCH24-O2 of 3 models qualify · AHRI 218599349No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBestcoldAll-around score, best modelPuremindAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Ducted, 2 tons79.5(50 is the typical model of its size class) (higher)MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-I10 of 11 models have all five ratings · AHRI 21760604937.0(50 is the typical model of its size class)PTF24B1-EBH4Uwith ducted air handler PTF24B1-EBH4UAlso listed as ATF24B1-EBH4U, CTF24B1-EBH4U6 of 6 models have all five ratings · AHRI 218725507
Ducted, 2.5 to 3 tons66.2(50 is the typical model of its size class) (higher)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I9 of 11 models have all five ratings · AHRI 21789646051.4(50 is the typical model of its size class)PTF36B1-EBH4Uwith ducted air handler PTF36B1-EBH4UAlso listed as ATF36B1-EBH4U, CTF36B1-EBH4U6 of 6 models have all five ratings · AHRI 218725508
Ducted, 3.5 to 4.5 tons73.3(50 is the typical model of its size class) (higher)MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-I19 of 22 models have all five ratings · AHRI 21765058038.1(50 is the typical model of its size class)PTF48B1-EBH4Uwith ducted air handler PTF48B1-EBH4UAlso listed as PTF60B1-EBH4U, ATF48B1-EBH4U, ATF60B1-EBH4U, CTF48B1-EBH4U and 1 more12 of 12 models have all five ratings · AHRI 218725509
Non-ducted, up to 1.5 tons77.3(50 is the typical model of its size class) (higher)MYTW09NA23BCH25ES-Owith ductless indoor unit MYTW09NA23BCH25ES-I32 of 32 models have all five ratings · AHRI 21807845077.1(50 is the typical model of its size class)PTW09B1-EBH5D-04with ductless indoor unit PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-0452 of 52 models have all five ratings · AHRI 218686859
Non-ducted, 2 tons58.5(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I7 of 7 models have all five ratings · AHRI 21807845358.5(50 is the typical model of its size class)PTW24B1-EBH5D-04with ductless indoor unit PTW24B1-EBH5D-04Also listed as ATW24B1-EBH5D-0412 of 12 models have all five ratings · AHRI 218686862
Non-ducted, 2.5 to 3 tons65.9(50 is the typical model of its size class) (higher)MYTW27NA23BCH24-O9 of 9 models have all five ratings · AHRI 21859934721.5(50 is the typical model of its size class)PTW36B1-EBH3O-04with ductless indoor unit PTW36B1-EBH3O-04Also listed as PTW36B1-BBH4O-04, ATW36B1-BBH4O-04, CTW36B1-BBH4O-047 of 7 models have all five ratings · AHRI 218686873
Non-ducted, 3.5 to 4.5 tons42.3(50 is the typical model of its size class)MYTW42NA23BCH24-O3 of 3 models have all five ratings · AHRI 218599349No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBestcoldPuremind
COP at 5°Fbeats 99% · 2.44MYMBW-36NA22BCH18-ONon-ducted, 2.5 to 3 tonsbeats 78% · 2.10PTW12C1-EBH4O-04Also listed as ATW12C1-EBH4O-04, CTW12C1-EBH4O-04Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 103%MYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tonsbeats 91% · 101%PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-04Non-ducted, up to 1.5 tons
HSPF2beats 84% · 9.8MYUA48NA23BCH19-ODucted, 3.5 to 4.5 tonsbeats 81% · 10.5PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-04Non-ducted, up to 1.5 tons
SEER2beats 90% · 24.0MYTW27NA23BCH24-ONon-ducted, 2.5 to 3 tonsbeats 85% · 25.0PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-04Non-ducted, up to 1.5 tons
EER2beats 98% · 14.0MYUA24NA23BCH20-ODucted, 2 tonsbeats 88% · 14.5PTW09B1-EBH5D-04Also listed as ATW09B1-EBH5D-04Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 97% · 25,800 Btu/hMYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tonsbeats 91% · 17,800 Btu/hPTW18B1-EBH5D-04Also listed as ATW18B1-EBH5D-04Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter