Skip to content

Bestcold heat pump efficiency: 79 outdoor models compared

Bestcold has 79 heat pump outdoor models certified with this refrigerant group, in 85 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Bestcold makes. Bestcold has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
79
AHRI certifications
85
Efficiency index
46%
Typical model vs same-size, same-type peers (72 models)
Meet CEE 2025
68.4%
54 models

How Bestcold compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Bestcold against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Bestcold’s own modelsBestcold is strongest on SEER2 (its typical model beats 51% of comparable models) and weakest on EER2 (39%).
  • Bestcold
  • Middle half of its models
  • Other ranked manufacturers
Bestcold

Source: AHRI Directory, NEEP · as of

Average peer percentile of Bestcold’s models
RatingBeats comparable modelsRankRaw median
Efficiency index72 models scored46%Not ranked—
COP at 5°F72 models scored45%Not ranked1.97
Capacity retention at 5°F72 models scored43%Not ranked72%
HSPF279 models scored48%Not ranked9.0
SEER279 models scored51%Not ranked18.5
EER279 models scored39%Not ranked11.2
Heating capacity at 5°F72 models scored46%Not ranked18,950 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Bestcold’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Bestcold (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1——14%22%
Ducted, 2 tons963%51%54%62%
Ducted, 2.5–3 tons950%48%51%56%
Ducted, 3.5–4.5 tons1854%55%61%59%
Non-ducted, up to 1.5 tons2643%38%46%48%
Non-ducted, 2 tons533%28%44%44%
Non-ducted, 2.5–3 tons835%51%34%35%
Non-ducted, 3.5–4.5 tons329%37%18%40%

Every Bestcold model in the market

Bestcold’s 79 models with a known size and duct type, over the shape of the whole catalog.
Bestcold models by size and ratingColoured: Bestcold · grey shapes: all 14,508 models · lines: catalog medians by size
  • Bestcold models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 79 bestcold models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Bestcold models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Bestcold cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1MYUSA24NA23BCH19-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA24NA23BCH19-I2 tons24,000 Btu/h · Ducted100%2.209.524,00018.5CEE 25CEE 26CEE AdvXcelDOE1217896463Ducted, 2 tons80.9
2MYUSA48NA23BCH18-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA48NA23BCH18-I4 tons48,000 Btu/h · Ducted75%2.259.836,00017.5CEE 25CEE 26Xcel1217896465Ducted, 3.5–4.5 tons76.6
3MYUA48NA23BCH19-OBestcold · T Serieswith ducted air handler MYUA48NA23BCH19-I4 tons48,000 Btu/h · Ducted73%2.209.835,00018.5CEE 25CEE 26XcelES CC1217896461Ducted, 3.5–4.5 tons73.3
4MYOA48NA22BCH18-OBestcoldwith ducted air handler MYOA48NA22BCH18-I4 tons47,000 Btu/h · Ducted72%2.309.234,00018.5CEE 25CEE 26Xcel1217650580Ducted, 3.5–4.5 tons72.2
5MYIRU24NA22BCH18*Bestcold2 tons24,000 Btu/h · Ducted103%1.949.525,80019.0CEE 25CEE 26Xcel1218814641Ducted, 2 tons70.4

All-around best

Top 5 Bestcold models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1MYGA36NA23BCH19-OBestcoldwith ducted air handler MYGA24NA23BCH20-I2 tons24,000 Btu/h · Ducted83%2.109.420.013.3CEE 25CEE 26Xcel2217606049Ducted, 2 tons79.667.292.167.2
2MYUA24NA23BCH20-OBestcold · T Serieswith ducted air handler MYUA24NA23BCH20-I2 tons24,000 Btu/h · Ducted74%2.209.520.014.0CEE 25CEE 26XcelES CC1217896459Ducted, 2 tons79.365.193.465.1
3MYIRU24NA22BCH18*Bestcold2 tons24,000 Btu/h · Ducted103%1.949.519.012.2CEE 25CEE 26Xcel1218814641Ducted, 2 tons73.570.476.670.4
4MYUSA24NA23BCH19-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA24NA23BCH19-I2 tons24,000 Btu/h · Ducted100%2.209.518.512.0CEE 25CEE 26CEE AdvXcelDOE1217896463Ducted, 2 tons73.580.966.280.9
5MYORU24NA22BCH19ESBestcold · Gable Series2 tons24,000 Btu/h · Ducted103%2.009.019.012.3CEE 25CEE 26XcelES CC1218690030Ducted, 2 tons73.168.777.568.7

Best model on each rating

Bestcold’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FMYOA48NA22BCH18-O2.30Ducted, 3.5–4.5 tons86%217650580
Capacity retention at 5°FMYIRU24NA22BCH18*103%Ducted, 2 tons97%218814641
HSPF2MYUA48NA23BCH19-O9.8Ducted, 3.5–4.5 tons84%217896461
SEER2MYTW27NA23BCH24-O24.0Non-ducted, 2.5–3 tons91%218599347
EER2MYUA24NA23BCH20-O14.0Ducted, 2 tons98%217896459
Heating capacity at 5°FMYIRU24NA22BCH18*25,800 Btu/hDucted, 2 tons97%218814641

All 79 Bestcold models in Explore

Bestcold size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Bestcold: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)
Ducted, 2 tons80.9(50 is the typical model of its size class)MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-I8 of 9 models qualify · AHRI 21789646379.6(50 is the typical model of its size class)MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-I8 of 9 models have all five ratings · AHRI 217606049
Ducted, 2.5–3 tons70.3(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I6 of 9 models qualify · AHRI 21789646065.1(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I7 of 9 models have all five ratings · AHRI 217896460
Ducted, 3.5–4.5 tons76.6(50 is the typical model of its size class)MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-I14 of 18 models qualify · AHRI 21789646572.6(50 is the typical model of its size class)MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-I15 of 18 models have all five ratings · AHRI 217650580
Non-ducted, up to 1.5 tons68.6(50 is the typical model of its size class)MYTW18NA23BCH24-O19 of 26 models qualify · AHRI 21859934672.2(50 is the typical model of its size class)MYTW18NA23BCH24-O26 of 26 models have all five ratings · AHRI 218599346
Non-ducted, 2 tons37.7(50 is the typical model of its size class)MYTW24NA23BCH24ES-Owith ductless indoor unit MYTD24NA23BCH24ES-IAlso listed as MYTD24NA23BCH24-O2 of 5 models qualify · AHRI 21859933748.8(50 is the typical model of its size class)MYTW24NA23BCH24ES-Owith ductless indoor unit MYTD24NA23BCH24ES-IAlso listed as MYTD24NA23BCH24-O5 of 5 models have all five ratings · AHRI 218599337
Non-ducted, 2.5–3 tons57.5(50 is the typical model of its size class)MYTW27NA23BCH24-O6 of 8 models qualify · AHRI 21859934765.1(50 is the typical model of its size class)MYTW27NA23BCH24-O8 of 8 models have all five ratings · AHRI 218599347
Non-ducted, 3.5–4.5 tons31.2(50 is the typical model of its size class)MYTW42NA23BCH24-O2 of 3 models qualify · AHRI 21859934942.4(50 is the typical model of its size class)MYTW42NA23BCH24-O3 of 3 models have all five ratings · AHRI 218599349

All-around board, every manufacturer

Newest Bestcold certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Bestcold outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
MYIRU60NA22BCH19*Bestcold4.5 tons55,000 Btu/h · Ducted1.8281%8.818.5CEE 25CEE 26Xcel1218814644
MYIRU48NA22BCH19*Bestcold4 tons48,000 Btu/h · Ducted1.8093%9.019.0CEE 25CEE 26Xcel1218814643
MYIRU36NA22BCH19*Bestcold3 tons34,200 Btu/h · Ducted1.8671%8.218.5Xcel1218814642
MYIRU24NA22BCH18*Bestcold2 tons24,000 Btu/h · Ducted1.94103%9.519.0CEE 25CEE 26Xcel1218814641
MYIRU60NA22BCH14*Bestcold4.5 tons55,000 Btu/h · Ducted1.8068%7.613.4None1218814640

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Bestcold

Manufacturers of a similar size, side by side.

Bestcold includes these brand names as listed in AHRI: Bestcold. Standards are checked against published thresholds; program rules beyond ratings are not checked.