Bestcold heat pump efficiency: 96 outdoor models compared
Bestcold has 96 heat pump outdoor models certified with this refrigerant group, in 108 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Bestcold makes. Bestcold has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 96
- AHRI certifications
- 108
- Efficiency index
- 46%
- Typical model vs same-size, same-type peers (89 models)
- Meet CEE 2025
- 65.6%
- 63 models
How Bestcold compares with comparable models
- Bestcold
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index89 models scored | 46% | Not ranked | — |
| COP at 5°F89 models scored | 43% | Not ranked | 1.89 |
| Capacity retention at 5°F89 models scored | 46% | Not ranked | 72% |
| HSPF296 models scored | 47% | Not ranked | 9.0 |
| SEER296 models scored | 51% | Not ranked | 18.5 |
| EER296 models scored | 40% | Not ranked | 11.2 |
| Heating capacity at 5°F89 models scored | 48% | Not ranked | 18,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 65.6% | 63 |
| CEE 2026 Tier 1 (Split ASHP) | 65.6% | 63 |
| CEE Advanced Tier (Split ASHP) | 1% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 62.5% | 60 |
| DOE Cold Climate Heat Pump Challenge | 1% | 1 |
| ENERGY STAR Cold Climate | 21.9% | 21 |
Sizes and duct types offered
- Bestcold (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | — | — | 16% | 23% |
| Ducted, 2 tons | 11 | 61% | 46% | 53% | 61% |
| Ducted, 2.5 to 3 tons | 11 | 46% | 41% | 47% | 54% |
| Ducted, 3.5 to 4.5 tons | 22 | 52% | 49% | 59% | 59% |
| Non-ducted, up to 1.5 tons | 32 | 44% | 37% | 47% | 49% |
| Non-ducted, 2 tons | 7 | 37% | 34% | 44% | 45% |
| Non-ducted, 2.5 to 3 tons | 9 | 35% | 56% | 31% | 33% |
| Non-ducted, 3.5 to 4.5 tons | 3 | 29% | 37% | 19% | 39% |
Every Bestcold model in the market
- Bestcold models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Bestcold in the cold
- All listed models (median, middle 50% and 80%)
- Bestcold (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Bestcold, 47°F | 49 | 100% | 100% | 100% | 100% | 100% |
| Bestcold, 17°F | 49 | 70% | 72% | 73% | 80% | 85% |
| Bestcold, 5°F | 49 | 57% | 61% | 66% | 72% | 74% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Bestcold, 47°F | 49 | 2.47 | 2.89 | 3.33 | 3.51 | 3.69 |
| Bestcold, 17°F | 49 | 1.97 | 2.09 | 2.2 | 2.25 | 2.4 |
| Bestcold, 5°F | 49 | 1.8 | 1.8 | 2 | 2.1 | 2.12 |
Source: NEEP ccASHP list · as of
Top Bestcold models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MYUSA24NA23BCH19-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA24NA23BCH19-I | 2 tons24,000 Btu/h · Ducted | 100% | 2.20 | 9.5 | 24,000 | 18.5 | CEE 25CEE 26CEE AdvXcelDOE | 1 | 217896463 | Ducted, 2 tons | 80.8 |
| 2MYUSA48NA23BCH18-OBestcold · SIDE-DISCHARGEwith ducted air handler MYUSA48NA23BCH18-I | 4 tons48,000 Btu/h · Ducted | 75% | 2.25 | 9.8 | 36,000 | 17.5 | CEE 25CEE 26Xcel | 1 | 217896465 | Ducted, 3.5 to 4.5 tons | 76.8 |
| 3MYUA48NA23BCH19-OBestcold · T Serieswith ducted air handler MYUA48NA23BCH19-I | 4 tons48,000 Btu/h · Ducted | 73% | 2.20 | 9.8 | 35,000 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 217896461 | Ducted, 3.5 to 4.5 tons | 73.5 |
| 4MYOA48NA22BCH18-OBestcoldwith ducted air handler MYOA48NA22BCH18-I | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 34,000 | 18.5 | CEE 25CEE 26Xcel | 1 | 217650580 | Ducted, 3.5 to 4.5 tons | 72.3 |
| 5MYIRU24NA22BCH18BestcoldAlso listed as MYIRU24NA22BCH18 | 2 tons24,000 Btu/h · Ducted | 103% | 1.94 | 9.5 | 25,800 | 19.0 | CEE 25CEE 26Xcel | 1 | 218137762 | Ducted, 2 tons | 70.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MYGA36NA23BCH19-OBestcoldwith ducted air handler MYGA24NA23BCH20-I | 2 tons24,000 Btu/h · Ducted | 83% | 2.10 | 9.4 | 20.0 | 13.3 | CEE 25CEE 26Xcel | 2 | 217606049 | Ducted, 2 tons | 79.5 | 66.8 | 92.2 | 66.8 |
| 2MYUA24NA23BCH20-OBestcold · T Serieswith ducted air handler MYUA24NA23BCH20-I | 2 tons24,000 Btu/h · Ducted | 74% | 2.20 | 9.5 | 20.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 217896459 | Ducted, 2 tons | 79.2 | 65.0 | 93.4 | 65.0 |
| 3MYTW09NA23BCH25ES-OBestcold · FrostFlowwith ductless indoor unit MYTW09NA23BCH25ES-I | 1 ton9,000 Btu/h · Non-ducted | 106% | 1.80 | 10.5 | 25.0 | 14.5 | CEE 25CEE 26XcelES CC | 1 | 218078450 | Non-ducted, up to 1.5 tons | 77.3 | 64.9 | 89.7 | 64.9 |
| 4MYOA24NA22BCH18-OBestcoldwith ducted air handler MYOA24NA22BCH18-I | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 9.5 | 19.0 | 13.2 | CEE 25CEE 26Xcel | 1 | 217650578 | Ducted, 2 tons | 76.5 | 67.6 | 85.3 | 67.6 |
| 5MYTW12NA23BCH25ES-OBestcold · FrostFlowwith ductless indoor unit MYTW12NA23BCH25ES-I | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218078451 | Non-ducted, up to 1.5 tons | 75.6 | 63.4 | 87.9 | 63.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MYMBW-36NA22BCH18-O | 2.44 | Non-ducted, 2.5 to 3 tons | 99% | 218806034 |
| Capacity retention at 5°F | MYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18 | 103% | Ducted, 2 tons | 97% | 218137762 |
| HSPF2 | MYUA48NA23BCH19-O | 9.8 | Ducted, 3.5 to 4.5 tons | 84% | 217896461 |
| SEER2 | MYTW27NA23BCH24-O | 24.0 | Non-ducted, 2.5 to 3 tons | 90% | 218599347 |
| EER2 | MYUA24NA23BCH20-O | 14.0 | Ducted, 2 tons | 98% | 217896459 |
| Heating capacity at 5°F | MYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18 | 25,800 Btu/h | Ducted, 2 tons | 97% | 218137762 |
Bestcold size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | 80.8(50 is the typical model of its size class)MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-I10 of 11 models qualify · AHRI 217896463 | 79.5(50 is the typical model of its size class)MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-I10 of 11 models have all five ratings · AHRI 217606049 |
| Ducted, 2.5 to 3 tons | 70.0(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I7 of 11 models qualify · AHRI 217896460 | 66.2(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I9 of 11 models have all five ratings · AHRI 217896460 |
| Ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class)MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-I17 of 22 models qualify · AHRI 217896465 | 73.3(50 is the typical model of its size class)MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-I19 of 22 models have all five ratings · AHRI 217650580 |
| Non-ducted, up to 1.5 tons | 70.1(50 is the typical model of its size class)MYTW18NA23BCH24-O22 of 32 models qualify · AHRI 218599346 | 77.3(50 is the typical model of its size class)MYTW09NA23BCH25ES-Owith ductless indoor unit MYTW09NA23BCH25ES-I32 of 32 models have all five ratings · AHRI 218078450 |
| Non-ducted, 2 tons | 59.1(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I3 of 7 models qualify · AHRI 218078453 | 58.5(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I7 of 7 models have all five ratings · AHRI 218078453 |
| Non-ducted, 2.5 to 3 tons | 58.2(50 is the typical model of its size class)MYTW27NA23BCH24-O6 of 9 models qualify · AHRI 218599347 | 65.9(50 is the typical model of its size class)MYTW27NA23BCH24-O9 of 9 models have all five ratings · AHRI 218599347 |
| Non-ducted, 3.5 to 4.5 tons | 31.5(50 is the typical model of its size class)MYTW42NA23BCH24-O2 of 3 models qualify · AHRI 218599349 | 42.3(50 is the typical model of its size class)MYTW42NA23BCH24-O3 of 3 models have all five ratings · AHRI 218599349 |
Newest Bestcold certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MYIRU60NA22BCH19*Bestcold | 4.5 tons55,000 Btu/h · Ducted | 1.82 | 81% | 8.8 | 18.5 | CEE 25CEE 26Xcel | 1 | 218814644 |
| MYIRU48NA22BCH19*Bestcold | 4 tons48,000 Btu/h · Ducted | 1.80 | 93% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218814643 |
| MYIRU36NA22BCH19*Bestcold | 3 tons34,200 Btu/h · Ducted | 1.86 | 71% | 8.2 | 18.5 | Xcel | 1 | 218814642 |
| MYIRU24NA22BCH18*Bestcold | 2 tons24,000 Btu/h · Ducted | 1.94 | 103% | 9.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 218814641 |
| MYIRU60NA22BCH14*Bestcold | 4.5 tons55,000 Btu/h · Ducted | 1.80 | 68% | 7.6 | 13.4 | None | 1 | 218814640 |