Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ACIQ heat pump efficiency: 175 outdoor models compared
ACIQ has 175 heat pump outdoor models certified with this refrigerant group, in 18,053 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ACIQ makes. ACIQ has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 175
- AHRI certifications
- 18,053
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (196 models)
- Meet CEE 2025
- 55.4%
- 97 models
How ACIQ compares with comparable models
- ACIQ
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index196 models scored | 50% | Not ranked | — |
| COP at 5°F196 models scored | 55% | Not ranked | 2.00 |
| Capacity retention at 5°F196 models scored | 43% | Not ranked | 69% |
| HSPF2196 models scored | 52% | Not ranked | 8.5 |
| SEER2196 models scored | 49% | Not ranked | 17.0 |
| EER2196 models scored | 52% | Not ranked | 11.2 |
| Heating capacity at 5°F196 models scored | 46% | Not ranked | 19,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 55.4% | 97 |
| CEE 2026 Tier 1 (Split ASHP) | 53.1% | 93 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 3 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 46.3% | 81 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 3 |
| ENERGY STAR Cold Climate | 33.7% | 59 |
Sizes and duct types offered
- ACIQ (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 16 | 64% | 75% | 61% | 63% |
| Ducted, 2 tons | 24 | 47% | 56% | 49% | 44% |
| Ducted, 2.5–3 tons | 36 | 49% | 57% | 48% | 46% |
| Ducted, 3.5–4.5 tons | 57 | 48% | 50% | 47% | 47% |
| Ducted, 5 tons and up | 7 | 65% | 73% | 64% | 53% |
| Non-ducted, up to 1.5 tons | 30 | 49% | 50% | 59% | 49% |
| Non-ducted, 2 tons | 7 | 50% | 61% | 60% | 46% |
| Non-ducted, 2.5–3 tons | 13 | 47% | 44% | 48% | 51% |
| Non-ducted, 3.5–4.5 tons | 5 | 52% | 37% | 73% | 47% |
| Non-ducted, 5 tons and up | 1 | 59% | 79% | 47% | 77% |
Every ACIQ model in the market
- ACIQ models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top ACIQ models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 7,700 | 25.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 216032333 | Non-ducted, up to 1.5 tons | 96.7 |
| 2ACIQ-09ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-09FM-HH-MD | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 8,600 | 26.0 | CEE 25CEE 26XcelES CC | 10 | 218471575 | Non-ducted, up to 1.5 tons | 89.5 |
| 3ACIQ-24ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24CC-HH-MC | 2 tons23,400 Btu/h · Non-ducted | 95% | 2.23 | 11.6 | 23,800 | 20.7 | CEE 25CEE 26XcelES CC | 5 | 216032341 | Non-ducted, 2 tons | 89.4 |
| 4ACIQ-36ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-36FM-HH-MD | 3 tons36,400 Btu/h · Non-ducted | 104% | 2.02 | 10.8 | 39,500 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 216032355 | Non-ducted, 2.5–3 tons | 89.4 |
| 5ACIQ-18-HPDACIQ · ACIQ Serieswith ducted air handler ACIQ-18W-WMB | 1.5 tons18,000 Btu/h · Ducted | 103% | 2.10 | 10.8 | 19,600 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 11 | 216980785 | Ducted, up to 1.5 tons | 86.6 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD | 0.5 tons6,000 Btu/h · Non-ducted | 110% | 2.40 | 14.8 | 25.5 | 18.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 216032333 | Non-ducted, up to 1.5 tons | 96.2 | 96.7 | 95.7 | 96.7 |
| 2ACIQ-09ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-09FM-HH-MD | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.27 | 13.9 | 26.0 | 16.2 | CEE 25CEE 26XcelES CC | 10 | 218471575 | Non-ducted, up to 1.5 tons | 92.6 | 89.5 | 95.7 | 89.5 |
| 3B5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCON | 5 tons58,000 Btu/h · Ducted | 74% | 2.18 | 9.0 | 20.0 | 12.5 | CEE 25CEE 26XcelES CC | 152 | 218628756 | Ducted, 5 tons and up | 89.1 | 82.3 | 96.0 | 82.3 |
| 4ACIQ-24ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24W-HH-MD | 2 tons24,000 Btu/h · Non-ducted | 78% | 2.54 | 11.7 | 23.0 | 14.0 | CEE 25CEE 26XcelES CC | 7 | 218471560 | Non-ducted, 2 tons | 86.8 | 84.5 | 89.1 | 84.5 |
| 5ACIQ-09ZPL-HP230CACIQ · ACIQ Serieswith ducted air handler ACIQ-09CD-HH-MC | 1 ton9,000 Btu/h · Ducted | 120% | 1.85 | 13.8 | 20.5 | 14.0 | CEE 25CEE 26XcelES CC | 7 | 216032344 | Ducted, up to 1.5 tons | 86.5 | 79.9 | 93.2 | 79.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ACIQ-18-HPD | 2.93 | Ducted, up to 1.5 tons | 99% | 217617061 |
| Capacity retention at 5°F | ACIQ-09ZPL-HP230C | 126% | Non-ducted, up to 1.5 tons | 98% | 216032351 |
| HSPF2 | ACIQ-06ZPL-HP230C | 14.8 | Non-ducted, up to 1.5 tons | 99% | 216032333 |
| SEER2 | H5H3V48*K*AAA*Also listed as B5H3V48*K*AAA | 23.0 | Ducted, 3.5–4.5 tons | 100% | 216635232 |
| EER2 | ACIQ-06ZPL-HP230C | 18.0 | Non-ducted, up to 1.5 tons | 99% | 216032333 |
| Heating capacity at 5°F | ACIQ-18-HPD | 19,600 Btu/h | Ducted, up to 1.5 tons | 98% | 216980785 |
ACIQ size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class)ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB11 of 16 models qualify · AHRI 216980785 | 86.5(50 is the typical model of its size class)ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC16 of 16 models have all five ratings · AHRI 216032344 |
| Ducted, 2 tons | 85.7(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC13 of 24 models qualify · AHRI 216032347 | 82.9(50 is the typical model of its size class)B5H3V24*K*AAA*with ducted air handler FCMA5B36L0C*+WALLCON22 of 22 models have all five ratings · AHRI 218628751 |
| Ducted, 2.5–3 tons | 83.2(50 is the typical model of its size class)ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC16 of 36 models qualify · AHRI 216032348 | 85.1(50 is the typical model of its size class)H5H3V36*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON37 of 37 models have all five ratings · AHRI 216635478 |
| Ducted, 3.5–4.5 tons | 85.1(50 is the typical model of its size class)ACIQ-60-HP32with ducted air handler ACIQ-60-AH3226 of 53 models qualify · AHRI 215387241 | 85.1(50 is the typical model of its size class)ES-48Z-M6C53 of 53 models have all five ratings · AHRI 216032386 |
| Ducted, 5 tons and up | 82.3(50 is the typical model of its size class)B5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON5 of 11 models qualify · AHRI 218628756 | 89.1(50 is the typical model of its size class)B5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON12 of 12 models have all five ratings · AHRI 218628756 |
| Non-ducted, up to 1.5 tons | 96.7(50 is the typical model of its size class)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD20 of 30 models qualify · AHRI 216032333 | 96.2(50 is the typical model of its size class)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD30 of 30 models have all five ratings · AHRI 216032333 |
| Non-ducted, 2 tons | 89.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24CC-HH-MC4 of 7 models qualify · AHRI 216032341 | 86.8(50 is the typical model of its size class)ACIQ-24ZS-HP230Cwith ductless indoor unit ACIQ-24W-HH-MD7 of 7 models have all five ratings · AHRI 218471560 |
| Non-ducted, 2.5–3 tons | 89.4(50 is the typical model of its size class)ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD8 of 13 models qualify · AHRI 216032355 | 78.3(50 is the typical model of its size class)ACIQ-36Z-HH-M5C13 of 13 models have all five ratings · AHRI 216032367 |
| Non-ducted, 3.5–4.5 tons | 73.4(50 is the typical model of its size class)ACIQ-48Z-HH-M6C5 of 5 models qualify · AHRI 216032372 | 75.6(50 is the typical model of its size class)ACIQ-48Z-HH-M6C5 of 5 models have all five ratings · AHRI 216032370 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 58.6(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032388 |
Newest ACIQ certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| N5H9V60*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D6021X | 4.5 tons55,500 Btu/h · Ducted | 2.00 | 71% | 8.1 | 17.5 | CEE 25CEE 26XcelES CC | 387 | 218822098 |
| N5H9V48*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D6021X | 4 tons46,000 Btu/h · Ducted | 2.12 | 76% | 10.0 | 19.0 | CEE 25CEE 26XcelES CC | 553 | 218822097 |
| N5H9V36*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D4821X | 3 tons35,400 Btu/h · Ducted | 2.00 | 71% | 9.0 | 18.0 | CEE 25CEE 26XcelES CC | 836 | 218822095 |
| N5H9V24*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D3617X | 2 tons23,800 Btu/h · Ducted | 1.90 | 95% | 8.6 | 19.5 | CEE 25CEE 26XcelES CC | 1,100 | 218822093 |
| N5H8T60*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D6021X | 5 tons58,000 Btu/h · Ducted | 2.34 | 51% | 8.1 | 17.5 | CEE 25CEE 26 | 419 | 218822091 |
Compare ACIQ
ACIQ includes these brand names as listed in AHRI: ACIQ. Standards are checked against published thresholds; program rules beyond ratings are not checked.