Skip to content

ACIQ heat pump efficiency: 175 outdoor models compared

ACIQ has 175 heat pump outdoor models certified with this refrigerant group, in 18,053 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ACIQ makes. ACIQ has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
175
AHRI certifications
18,053
Efficiency index
50%
Typical model vs same-size, same-type peers (196 models)
Meet CEE 2025
55.4%
97 models

How ACIQ compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
ACIQ against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of ACIQ’s own modelsACIQ is strongest on COP at 5°F (its typical model beats 55% of comparable models) and weakest on capacity retention at 5°F (43%).
  • ACIQ
  • Middle half of its models
  • Other ranked manufacturers
ACIQ

Source: AHRI Directory, NEEP · as of

Average peer percentile of ACIQ’s models
RatingBeats comparable modelsRankRaw median
Efficiency index196 models scored50%Not ranked—
COP at 5°F196 models scored55%Not ranked2.00
Capacity retention at 5°F196 models scored43%Not ranked69%
HSPF2196 models scored52%Not ranked8.5
SEER2196 models scored49%Not ranked17.0
EER2196 models scored52%Not ranked11.2
Heating capacity at 5°F196 models scored46%Not ranked19,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
ACIQ’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • ACIQ (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons1664%75%61%63%
Ducted, 2 tons2447%56%49%44%
Ducted, 2.5–3 tons3649%57%48%46%
Ducted, 3.5–4.5 tons5748%50%47%47%
Ducted, 5 tons and up765%73%64%53%
Non-ducted, up to 1.5 tons3049%50%59%49%
Non-ducted, 2 tons750%61%60%46%
Non-ducted, 2.5–3 tons1347%44%48%51%
Non-ducted, 3.5–4.5 tons552%37%73%47%
Non-ducted, 5 tons and up159%79%47%77%

Every ACIQ model in the market

ACIQ’s 196 models with a known size and duct type, over the shape of the whole catalog.
ACIQ models by size and ratingColoured: ACIQ · grey shapes: all 14,508 models · lines: catalog medians by size
  • ACIQ models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 196 aciq models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top ACIQ models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 ACIQ cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ACIQ-06ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD0.5 tons6,000 Btu/h · Non-ducted110%2.4014.87,70025.5CEE 25CEE 26CEE AdvXcelDOEES CC4216032333Non-ducted, up to 1.5 tons96.7
2ACIQ-09ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-09FM-HH-MD1 ton9,000 Btu/h · Non-ducted96%2.2713.98,60026.0CEE 25CEE 26XcelES CC10218471575Non-ducted, up to 1.5 tons89.5
3ACIQ-24ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24CC-HH-MC2 tons23,400 Btu/h · Non-ducted95%2.2311.623,80020.7CEE 25CEE 26XcelES CC5216032341Non-ducted, 2 tons89.4
4ACIQ-36ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-36FM-HH-MD3 tons36,400 Btu/h · Non-ducted104%2.0210.839,50020.0CEE 25CEE 26XcelES CC3216032355Non-ducted, 2.5–3 tons89.4
5ACIQ-18-HPDACIQ · ACIQ Serieswith ducted air handler ACIQ-18W-WMB1.5 tons18,000 Btu/h · Ducted103%2.1010.819,60019.3CEE 25CEE 26CEE AdvXcelDOEES CC11216980785Ducted, up to 1.5 tons86.6

All-around best

Top 5 ACIQ models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ACIQ-06ZPL-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-06W-HH-MD0.5 tons6,000 Btu/h · Non-ducted110%2.4014.825.518.0CEE 25CEE 26CEE AdvXcelDOEES CC4216032333Non-ducted, up to 1.5 tons96.296.795.796.7
2ACIQ-09ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-09FM-HH-MD1 ton9,000 Btu/h · Non-ducted96%2.2713.926.016.2CEE 25CEE 26XcelES CC10218471575Non-ducted, up to 1.5 tons92.689.595.789.5
3B5H3V60*K*AAA*ACIQ · Deluxe 23 VS Heat Pumpwith ducted air handler FCMA5B60L0D*+WALLCON5 tons58,000 Btu/h · Ducted74%2.189.020.012.5CEE 25CEE 26XcelES CC152218628756Ducted, 5 tons and up89.182.396.082.3
4ACIQ-24ZS-HP230CACIQ · ACIQ Serieswith ductless indoor unit ACIQ-24W-HH-MD2 tons24,000 Btu/h · Non-ducted78%2.5411.723.014.0CEE 25CEE 26XcelES CC7218471560Non-ducted, 2 tons86.884.589.184.5
5ACIQ-09ZPL-HP230CACIQ · ACIQ Serieswith ducted air handler ACIQ-09CD-HH-MC1 ton9,000 Btu/h · Ducted120%1.8513.820.514.0CEE 25CEE 26XcelES CC7216032344Ducted, up to 1.5 tons86.579.993.279.9

Best model on each rating

ACIQ’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FACIQ-18-HPD2.93Ducted, up to 1.5 tons99%217617061
Capacity retention at 5°FACIQ-09ZPL-HP230C126%Non-ducted, up to 1.5 tons98%216032351
HSPF2ACIQ-06ZPL-HP230C14.8Non-ducted, up to 1.5 tons99%216032333
SEER2H5H3V48*K*AAA*Also listed as B5H3V48*K*AAA23.0Ducted, 3.5–4.5 tons100%216635232
EER2ACIQ-06ZPL-HP230C18.0Non-ducted, up to 1.5 tons99%216032333
Heating capacity at 5°FACIQ-18-HPD19,600 Btu/hDucted, up to 1.5 tons98%216980785

All 175 ACIQ models in Explore

ACIQ size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
ACIQ: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons86.6(50 is the typical model of its size class)ACIQ-18-HPDwith ducted air handler ACIQ-18W-WMB11 of 16 models qualify · AHRI 21698078586.5(50 is the typical model of its size class)ACIQ-09ZPL-HP230Cwith ducted air handler ACIQ-09CD-HH-MC16 of 16 models have all five ratings · AHRI 216032344
Ducted, 2 tons85.7(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ducted air handler ACIQ-24CD-HH-MC13 of 24 models qualify · AHRI 21603234782.9(50 is the typical model of its size class)B5H3V24*K*AAA*with ducted air handler FCMA5B36L0C*+WALLCON22 of 22 models have all five ratings · AHRI 218628751
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class)ACIQ-36ZPL-HP230Cwith ducted air handler ACIQ-36CD-HH-MC16 of 36 models qualify · AHRI 21603234885.1(50 is the typical model of its size class)H5H3V36*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON37 of 37 models have all five ratings · AHRI 216635478
Ducted, 3.5–4.5 tons85.1(50 is the typical model of its size class)ACIQ-60-HP32with ducted air handler ACIQ-60-AH3226 of 53 models qualify · AHRI 21538724185.1(50 is the typical model of its size class)ES-48Z-M6C53 of 53 models have all five ratings · AHRI 216032386
Ducted, 5 tons and up82.3(50 is the typical model of its size class)B5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON5 of 11 models qualify · AHRI 21862875689.1(50 is the typical model of its size class)B5H3V60*K*AAA*with ducted air handler FCMA5B60L0D*+WALLCON12 of 12 models have all five ratings · AHRI 218628756
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD20 of 30 models qualify · AHRI 21603233396.2(50 is the typical model of its size class)ACIQ-06ZPL-HP230Cwith ductless indoor unit ACIQ-06W-HH-MD30 of 30 models have all five ratings · AHRI 216032333
Non-ducted, 2 tons89.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Cwith ductless indoor unit ACIQ-24CC-HH-MC4 of 7 models qualify · AHRI 21603234186.8(50 is the typical model of its size class)ACIQ-24ZS-HP230Cwith ductless indoor unit ACIQ-24W-HH-MD7 of 7 models have all five ratings · AHRI 218471560
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class)ACIQ-36ZPL-HP230Cwith ductless indoor unit ACIQ-36FM-HH-MD8 of 13 models qualify · AHRI 21603235578.3(50 is the typical model of its size class)ACIQ-36Z-HH-M5C13 of 13 models have all five ratings · AHRI 216032367
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class)ACIQ-48Z-HH-M6C5 of 5 models qualify · AHRI 21603237275.6(50 is the typical model of its size class)ACIQ-48Z-HH-M6C5 of 5 models have all five ratings · AHRI 216032370
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)58.6(50 is the typical model of its size class)ES-55Z-M6C1 of 1 models have all five ratings · AHRI 216032388

All-around board, every manufacturer

Newest ACIQ certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified ACIQ outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
N5H9V60*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D6021X4.5 tons55,500 Btu/h · Ducted2.0071%8.117.5CEE 25CEE 26XcelES CC387218822098
N5H9V48*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D6021X4 tons46,000 Btu/h · Ducted2.1276%10.019.0CEE 25CEE 26XcelES CC553218822097
N5H9V36*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D4821X3 tons35,400 Btu/h · Ducted2.0071%9.018.0CEE 25CEE 26XcelES CC836218822095
N5H9V24*K*AAA*ACIQ · Performance 19 SEER2 VS HPwith ducted air handler QFVA5D3617X2 tons23,800 Btu/h · Ducted1.9095%8.619.5CEE 25CEE 26XcelES CC1,100218822093
N5H8T60*K*AAA*ACIQ · 2-STAGE 18 SEER HPwith ducted air handler QFVA5D6021X5 tons58,000 Btu/h · Ducted2.3451%8.117.5CEE 25CEE 26419218822091

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare ACIQ

Manufacturers of a similar size, side by side.

ACIQ includes these brand names as listed in AHRI: ACIQ. Standards are checked against published thresholds; program rules beyond ratings are not checked.